Re: 7603 specifically and general refurbishment procedures of older oscilloscopes
IMHO only replace electrolytic caps that have failed, those big Sprague caps are normally OK except when they go open-circuit.
toggle quoted message
Show quoted text
Dave -----Original Message-----
From: [email protected] [mailto:[email protected]] On Behalf Of johnasolecki@... Sent: 24 July 2018 12:40 To: [email protected] Subject: Re: [TekScopes] 7603 specifically and general refurbishment procedures of older oscilloscopes Thanks for the suggestions. I'm pretty certain I had all the buttons pressed correctly but I'll recheck that (wouldn't be the first time...!) and I'll try to check the unblanking circuitry. What about capacitors and other aging components? As needed or change them all? John |
Re: Homemade tunnel diodes
I did not know about NLTLs, thanks Bruce for the heads up.
For those in my case, I have found a few references on the net: All documents refer to simulations made using Spice/LTSPice/ADS Not many people seem to have made DIY NLTL, let alone samplers based on it. On Mon, Jul 23, 2018 at 10:26 PM Bruce Griffiths <bruce.griffiths@...> wrote: For the purposes of harmonic generation NLTLs have much lower PN than SRDs. |
Re: 465B - Power Switch Mounting Nut Question
¸é±ð²Ô¨¦ Rajesh,
toggle quoted message
Show quoted text
Thanks for the replies and pics. I thought that was correct but just wanted to make sure. Thanks, Barry - N4BUQ ----- Original Message -----
From: "Barry" <n4buq@...> |
Re: Tek bits
Hi Guys,
toggle quoted message
Show quoted text
If there is too much for Craig, I would be interested to do a sharing-type deal. I live in London, UK. Both Craig and I wouldn't have any import problems, I think. This is only if Craig can't take everything, he has first shout. It would be useful to know in a bit more detail what is being offered, here. I am guessing that these originally came from Tektronix, Guernsey as did my 7623A? Regards, Colin. -----Original Message-----
From: [email protected] [mailto:[email protected]] On Behalf Of Craig Sawyers Sent: 24 July 2018 11:59 To: [email protected] Subject: Re: [TekScopes] Tek bits Hi Andre I'm near Oxford UK and would be very pleased to have these. Regards Craig -----Original Message-----de guerin via Groups.Io$Deity knows what happened."<c.sawyers@...> wrote: long pots.have a few flybacks but notWhere on planet earth are you? |
Re: 7603 specifically and general refurbishment procedures of older oscilloscopes
Thanks for the suggestions. I'm pretty certain I had all the buttons pressed correctly but I'll recheck that (wouldn't be the first time...!) and I'll try to check the unblanking circuitry.
What about capacitors and other aging components? As needed or change them all? John |
TEK 455
Hi Folks
I am working on a tek 455 scope. managed get the trace up. facing a trig problem. doesnt trig in auto/normal/single sweep. trig view signal ok. suspect trig ic 155-0122-00 is this ic used in any other tek scope so that i can try to cannibalise and get this going Thanks in advance regards Anand |
Re: Tek bits
Craig Sawyers
Hi Andre
toggle quoted message
Show quoted text
I'm near Oxford UK and would be very pleased to have these. Regards Craig -----Original Message----- |
Re: Tek bits
Tiny island near France, called Guernsey.
www.cwgsy.net/private/mandoline "Error 008472. Horrible bug encountered. $Deity knows what happened." On Monday, 23 July 2018, 09:04:47 GMT+1, Craig Sawyers <c.sawyers@...> wrote: > Hi, in my shed I have a lot of Tek bits including very hard-to-find long pots.have a few flybacks but notWhere on planet earth are you? Craig |
Re: 465B - Power Switch Mounting Nut Question
Hey Barry,
toggle quoted message
Show quoted text
Ive added two pics from my 465 to your album, the Slit needs to align in to the PCB. /g/TekScopes/album?id=64907 hope it helps, regards Rajesh On Mon, Jul 23, 2018 at 7:28 PM, n4buq <n4buq@...> wrote:
A few months ago, I removed the trigger board from my 465B to work on the --
/Rajesh |
Bringing up a Tek 555 dual-beam scope
Just bought a Tek 555 scope with cart and power supply. The scope appeared to have been used until replaced by a couple of 4xx series scopes but just shunted aside when replaced.
I owned and used a 555 40 years ago (warmed my basement quite well) but that scope, a Frankenstein monster created by plugging the CRT unit from one into the power supply from another, not only worked but was calibrated when turned on. As a result I never had to do any work on the unit. Are there any precautions I should take when powering up this unit? One suggestion is to plug it in and turn it on; if the magic smoke escapes find where it came from and fix it. I do have a Variac and am thinking about building one of the devices which has a large incandescent in series with the DUT. I do note that the contacts on some of the plug-ins are quite dirty, so I'm going to give the unit a good cleaning before firing it up. I will also check the big electrolytics for signs of failure and possibly for high ESR. My first scope was a Tek 511; I had to rebuild the HV supply as the diodes had failed. I currently have a 465B which is working well. Mike Squires wwww.siralan.org or www.smithgreensound.com UN*X at home since 1986 |
Re: Tektronix DM5010 NiCa 2.4V battery replacement
Hi everyone,
Please keep in mind that this DMM has been available since the very beginning of the eighties, if not late seventies. It has been designed about ten or less years after man walked on moon. We should now be able to replace the entire CPU board with a single $2-3 micro-controller. Best regards, |
Re: Weird serial number on 7L14
Bruce
toggle quoted message
Show quoted text
The list doesn't accept attachments. You will have to upload it to the photos section or host it somewhere and then post a link Dave manuals@... On 7/24/2018 1:44 AM, Bruce Lane wrote:
Fellow Tekkies, --
Dave Manuals@... www.ArtekManuals.com |
Re: 465B - Power Switch Mounting Nut Question
Hi Barry, a few weeks ago I had to do the same (horrible) job of replacing the power supply caps in my 475A, same construction. And I also wondered why Tek used such a "distance" holder for the PCB to lock the nut. I mount it exactly as yours in the first picture and it?s sitting sturdy and fine.
So if you mount it as picture 1 and it?s alligned with the other board it is OK. ¸é±ð²Ô¨¦ |
Weird serial number on 7L14
Fellow Tekkies,
I picked up a 7L14 from an estate sale this last weekend. One of the things which struck me is the bizarre serial number the thing has -- See the attached photo. My best guess is -- Prototype? Something which was never officially in production? I've never seen the middle symbol (small circle with a vertical slash through it) used on any Tek instrument I've ever owned. The other oddity with it is it seems to be missing its red filter window over the LED display on the input module side (see other photo). Is this something which can be replaced easily? Perhaps scavenged from, say, a dead 7A13? They look like they're about the same dimensions. Thanks much! -- --- Bruce Lane, ARS KC7GR kyrrin (at) bluefeathertech dot com "Quando Omni Flunkus Moritati" (Red Green) |
Re: Tektronix DM5010 NiCa 2.4V battery replacement
Hi Russ:
toggle quoted message
Show quoted text
You have a very valid point concerning corrosion due to batteries leaking.? It is probably a matter of economics that makes the manufacturer continue to provide super thin casings.? Also, the casing cannot encompass the entire battery, there must be electrical isolation between the terminals which is a natural source of leaking.? If the manufacturer were to encompass the battery in a leak proof shell the weight, cost and size would go up dramatically.? It all boils down to the almighty buck! Reed Dickinson On 7/23/2018 9:45 PM, musicamex wrote:
Half a century after men walked on the moon, can anyone please explain why |
Re: Tektronix DM5010 NiCa 2.4V battery replacement
On Mon, 23 Jul 2018 23:45:15 -0500, you wrote:
Half a century after men walked on the moon, can anyone please explain whyBecause the batteries don't cost $20,000 each. They're made (for primary cells) as throwaways. For secondary cells, it's the cost. Or why engineers capable of designing incredibleThey've all been laid off because they are too old, those that did not retire. You could protect the circuits, just put the battery in a hermeticly sealed enclosure. Look at the original post, though. The DM5010 had a VERY leaky battery (don't ask how I know) and as such, the battery was to be replaced every two to three years. This was well within the point where the battery would leak, so no problem. What the equipment was NOT designed to do was to sit idle on a shelf for five to fifteen years, not being used, not being charged, while the innards of the 5 dollar battery merrily ate away at the seals, or the shell, way after the point at which the battery would have been replaced. Lithium primary cells don't seem to be so badly behaved, although if you charge the secondary cells wrongly, or short either one; well, overheating as well as realize that lithium IS very fond of oxygen. We don't have a good cell chemistry yet, not one that can be charged thousands of times, has a good power to weight ratio, and so on. Still looking at the electron valence voltages between something electropositive and electronegative, and hoping that it's stable, light weight, and hopefully part of a reversible chemical action. How to store charge/power WELL is something we don't really know yet. Harvey I'm sure that I'm not the only one who has lost often irreplaceable |
Re: Tektronix DM5010 NiCa 2.4V battery replacement
Half a century after men walked on the moon, can anyone please explain why
toggle quoted message
Show quoted text
batteries still leak? Or why engineers capable of designing incredible electronics can't at least protect the circuits from leak caused damage? I'm sure that I'm not the only one who has lost often irreplaceable electronics to this pitfall. Russ On Monday, July 23, 2018, Kevin Oconnor <kjo@...> wrote:
You can certainly trickle charge some NiMH cells depending on the mfgr. --
Good judgement comes from experience; experience comes from bad judgement. 99 times out of 10 a blown fuse is not due to a bad fuse..... |
Re: Tektronix DM5010 NiCa 2.4V battery replacement
You can certainly trickle charge some NiMH cells depending on the mfgr. I¡¯ve used Panasonic cells that have a trickle charge spec. The trick is that the trickle charge level can¡¯t generate more evolved oxygen than can be absorbed at operating temps. That is the upper bound on trickle charging.
There is also a lower bound on trickle charging that is often overlooked. You have about 15-20 hrs max to recharge to full capacity. The reasoning by mfgrs is vague but true and likely related to temp rise and gas evolution. If you trickle charge at a rate less than that which will fully recharge in 15-20 hrs you will never fully restore full capacity. Kjo Sent from kjo iPhone |
465B - Power Switch Mounting Nut Question
A few months ago, I removed the trigger board from my 465B to work on the power supply caps. I started reassembling it and was left with a small nylon(?) block with a hex nut holder and a small slot in it. See the album below for pictures of it.
/g/TekScopes/album?id=64907 If I'm not mistaken, I think this is used behind the nut that holds the power switch in place and I used it that way (last picture); however, I'm wondering if I have it turned 180-degrees and the small slot is supposed to align with the main board. Is that where that part goes and, if so, is it supposed to align with the other PC board? I've found one picture on the web that shows it and I think that's correct but would like to know whether I have that right. Thanks, Barry - N4BUQ |