Re: Looking for rear feet for 2465 DVM scope
Jason,
I wonder if the caps inside are going bad even though it appears to work. The oscillation could also be decoupling is too low or not at all. If the original electrolytics are still there, replacing would be best. Condor Audio has a kit. The owner owner is on this group. What Siggi said sounds good. That could be your problem. Dirty contacts will cause weird problems. Mark |
Re: Looking for rear feet for 2465 DVM scope
On Thu, May 8, 2025 at 8:59?PM Jason B via groups.io <sydbowen=
[email protected]> wrote: I've tried DC balance. I was mistaken on the channel 2 waveform on GND.Interesting. Below 50mV/DIV the preamp amplifies the incoming signal, so it's perhaps within reason that it's amplifying something at the BNC. I guess it might also be oscillating. Have you measured the DC resistance of your inputs? It should be as near to 1MOhm as makes no difference in DC coupling and infinite in AC coupling. What happens: - In 50Ohm coupling? - In DC coupling? - When you connect a probe? - When you connect coaxes of different lengths? - At other attenuation settings? The CH1/CH2 preamp hybrids should be interchangeable (though the calibration is preamp specific, so keep track of which is which), so you might see whether this oddness follows the preamp. It's also possible that the hybrid contacts are oxidized, leading to weirdness, so before you swap them, try just re-seating them and/or cleaning their contacts. |
Re: Nothing built like Tektronix, period!
Radu, you are always exceedingly polite!
toggle quoted message
Show quoted text
I¡¯m surprised you had difficulty working on a Wavetek generator. I repaired my model 166 function generator about 8 years ago, and I don¡¯t remember it being particularly difficult or inconvenient. Unfortunately it¡¯s back to its old trick of the square and pulse outputs flatlining after a few minutes of operation. Last time, it turned out to be a flaky connector between the power supply board and the main board. I bent the offending pin so that it made a positive connection. I will check this weekend what¡¯s ailing it now. Good luck and have a great weekend everyone! Jim Ford Laguna Hills, California, USA On May 9, 2025, at 1:49?AM, David via groups.io <vexorg.calibra@...> wrote: |
Re: Slightly OT: Question on commercial PCBs (such as PC computer motherboards) vs "one off" or prototype PCBs (Oshpark / JLCPCB)
On Fri, May 9, 2025 at 06:29 AM, Roy Thistle wrote:
It could be.The smell in the welders was evident on brand new units and replacement PCB's Over time it went away. Other brands from Europe (Kemppi, ESAB, etc), Australia (Cigweld) and USA (Lincoln) didn't have the same strong smell. Jared |
Re: Nothing built like Tektronix, period!
I have the same experience with some Waveteks - a sweep/signal generator in
my case - and working on it has not been fun. Furthermore, I think the design was fundamentally less than stellar (to be exceedingly polite), but even as much as trying to repair it was underwhelming and sometimes frustrating. I've been avoiding similar units since, though Wavetek has some very good metrology units that may change my mind if I try to fix them. On Thu, May 8, 2025 at 8:46?PM naikm via groups.io <naikm= [email protected]> wrote: Today, was trying to fix a Wiltron 610D sweep generator with no output. |
Nothing built like Tektronix, period!
Today, was trying to fix a Wiltron 610D sweep generator with no output. Opening it up revealed the very difficult path to just accessing any of their boards. No slack in connecting wires, no way to access components, etc. Maybe, I'm used to the cool parking lot layout of Tektronix. Anyone have any experience on Wiltron? I won't dare try to fix another one again.
|
Re: Extra Tektronix 155-0019-00 part (free)
Yes, my address is good in QRZ. I'll certainly pass it on if someone needs it before I do (and I hope I never do but...).
toggle quoted message
Show quoted text
Thanks! Barry - N4BUQ How about I send it your way, with the promise that you'll pass it along if |
Re: Looking for rear feet for 2465 DVM scope
I've tried DC balance. I was mistaken on the channel 2 waveform on GND. It's on AC. I have it set right now at 2 mVAC and 2 nS on channel 2 with no probes connected and readout on frequency is 850 MHz with a perfect sine wave at 3.55 mV. Lol, I think I acquired a basket case maybe?
|
Re: Tektronix 547 Lack of Sweep or Intensity Control
I'm sorry to have break some bad news but it looks like you may have a grid-cathode short, or at least leakage, in the CRT. Either way there should not be HV on the grid if you have isolated it by lifting R830. If you're lucky the short will be in the wiring rather than in the tube. You can try unplugging the CRT socket (with the power off!!) and measuring the resistance between CRT pins 3 (grid) and 2 (cathode). It should be an open circuit. If it is, do the same for the socket. That should also be an open circuit if R830 has ben lifted and C829 and 830 are good.
Lifting the grid supply is generally not a good idea because if there is any DC leakage path to ground from the grid, the full HV will be impressed between grid and cathode which would not be good for the CRT, to put it mildly. If there's a grid-cathode short in the CRT then it's toast. Morris |
Re: Extra Tektronix 155-0019-00 part (free)
I don't exactly need it right now and I don't want to be a pig about it, but I have a several 7000-series scopes and the read-out boards have given me trouble on most of them so having a good replacement IC would be of interest to me if you don't have any other takers.
toggle quoted message
Show quoted text
Thanks, Barry - N4BUQ Hello, |
Re: Slightly OT: Question on commercial PCBs (such as PC computer motherboards) vs "one off" or prototype PCBs (Oshpark / JLCPCB)
On Thu, May 8, 2025 at 06:18 AM, Harold Foster wrote:
It could be. But welding machines get hot. And so, that drives out VOCs that wouldn't normally be driven out in such concentrations, at room temperature. Likely to me... unless you microwave your motherboards, and PCBs first (which I have done... don't do it!) ...more likely it is the VOCs in the cheap anti-static bags, the PCBs are shipped in. Has anyone said what the 'smell' actually smells like? -- Roy Thistle |
Re: Looking for rear feet for 2465 DVM scope
On Thu, May 8, 2025 at 11:32?AM Jason B via groups.io <sydbowen=
[email protected]> wrote: I'm slowly but surely finding more problems. I found the fan collet There is a trick to releasing these, but they're also quite brittle. I machined some replacements from delrin a few years ago (I'm out now), but there's a 3D model available for printing: . IDK whether this will work on a regular FDM printer, but it's easy enough to try if you have access to one. Busted a plastic clip inside only one of the knobs so far while removing I also learned too late that it's not necessary to remove these little knobs to get the front panel off. and noticed that channel 2 on the lowest V/div shows a trace that is oneHave you tried the AUTO DC Balance adjustment? From memory you put CH1 and CH2 in AC coupling, then pull both switches up. |