开云体育

ctrl + shift + ? for shortcuts
© 2025 开云体育
Re: Tektronix 2247A problem. Keep or return?
No need to use an isolation transformer to float the scope for this measurement. The chassis of the scope is grounded normally, not like old CRT TVs or monitors that mostly had a "hot" chassis. Just
By Alex · #209091 ·
Re: Tektronix 2247A problem. Keep or return?
You could download that BIN file and program it into a new prom chip. Perhaps the existing one is flaky, hence the come and go error?
By Alex · #209090 ·
Re: Tektronix 2247A problem. Keep or return?
This scope has me scratching my head. I had it running all night without any problem, I doubt part number 160-2393-00 is actually the culprit despite the occasional startup error. I suppose I should
By Jay Czaja · #209089 ·
Re: For my 7854 looking for MicroLab I
Hi Alberto! Your scope powers up correctly. The SRQ light stays on because a power cycle was detected. This can be cleared via GPIB or the Keyboard (see manual). You can ignore this. As far as I can
By Holger Lübben · #209088 ·
Re: For my 7854 looking for MicroLab I
Tnx Holger (and others)! I will study more deeply the service documentation, because I didn’t note an easier troubleshooting approach to the digital section. I am just equipped with the signature
By Alberto, IZ2EWV · #209087 ·
Re: New Customs Duties on Imports to the USA, regarding CondorAudio Tekscope Kits
The simple solution is just boycott the USA.
By David · #209086 ·
Re: sc504 Ghost Images
Dear Barry Suggest you read the excellent Tektronix Circuit Concept book on oscilloscope CRTs, and learn about the development and characteristics of mesh dome CRT. Then follow the service manual on
By Jean-Paul · #209085 ·
Re: Tektronix 2247A problem. Keep or return?
I have a bit more info. I started the scope up again and I got the initial interrupt error that I posted in the beginning of this thread. When I shut it off and started it back up, I was able to read
By Jay Czaja · #209084 ·
Re: sc504 Ghost Images
Jean-Paul and Raymond, Is there anything that can be done to improve this behavior? I was thinking that reducing the sensitivity of the intensity adjustment might help. Thoughts? Barry
By Barry Breaux · #209083 ·
Re: New Customs Duties on Imports to the USA, regarding CondorAudio Tekscope Kits
Hello, For all those of you new to customs - in Europe we had it for 20 years. Small video is at <https://youtu.be/XCgWlNomEgo?feature=shared> which should answer some questions. Tam -- With best
By Tam Hanna · #209082 ·
Re: Tektronix 2247A problem. Keep or return?
Noise may be HV corona j
By Jean-Paul · #209081 ·
Re: New Customs Duties on Imports to the USA, regarding CondorAudio Tekscope Kits
Dear Menecham: Very timely note, suggest to repost on Tekscopes2 and BUY/SELL forums. Perhaps also EEVblog? We have seen congress in US proposing removing the deminimus exemption. The entire
By Jean-Paul · #209080 ·
Re: Tektronix 2247A problem. Keep or return?
Alright, so I'm not in the clear with this 2247A. I've been busy with other things and had the scope off for about 3 days. Turned it on this morning and noticed the trace was a little noisy without a
By Jay Czaja · #209079 ·
Re: fitting new 'sleepy eye' power indicator to 2465 'scope?
I have a sleepy-eye assembly, switch attached to cable, if interested. I got it from the Tek Country Store (Tek salvage and surplus). It appears to be unused. Photographs at
By Clark Foley · #209077 ·
Re: sc504 Ghost Images
Raymond! YES I mewant CRT expansion mesh, the SC504 have it bad, due to CRT geom, the SC501/2/3 do NOT Cheers Jon
By Jean-Paul · #209076 ·
New Customs Duties on Imports to the USA, regarding CondorAudio Tekscope Kits
I've had a couple of enquiries from US members here, requesting clarity on the new Customs Duties - which may or may not be applicable on my 24xx series Tekscope kits, which are shipped from here in
By M Yachad · #209075 ·
Re: Help with 2465B failing display please...
According to Findchips.com, Quest Components has VN1316
By Jack Walton · #209074 ·
Re: Help with 2465B failing display please...
Thanks to all that have posted - it looks like I'm just going to find the time to open it up and start diagnosing. My feeling, and that that seems to be the opinion here as well, is that the fault
By Harold Foster · #209073 ·
Re: horz output FETs in 2245?
These parts are being operated in their linear region, so Rds(on) isn't relevant. As long as they can take the heat, what we need is agility, that is, minimal
By Dave Wise · #209072 ·
Re: sc504 Ghost Images
internal CRT phosphor beam reflection ? My money’s on scan expansion mesh (to increase deflection sensitivity) artefacts. Raymond
By Raymond Domp Frank · #209071 ·