Has anyone measured the low frequency (like 1 kHz) primary inductance of a normal, OK 576 HV transformer? I looked at the data sheets (at tekwiki) on the part, and none appear to show any inductance value. I've been pondering possible alternate solutions to the "bad epoxy" transformer problem. The first is a drop-in two-transformer (one to provide the HF power and +225V, the other to make the HV) scheme, to sub for only the original transformer. The other is a replacement for the HV supply section, basically an independent SMPS that can run from the +100V supply, like the original.
My 576s are good, with the newer "black" transformers, but all the recent talk got me interested, and revisiting ideas I've been thinking about over the years.
In case anything major should happen to the HV transformer or HV guts, I'd like to be ready to fix it, without resorting to rewinding the HV transformer. In either scenario, the plan is to use a "modern," off-shelf type small HF-HV transformer to provide the 4 kV. I'm picturing the little kind commonly used in Royer converters for LCD CCFL backlighting. I have many dozens of all sorts of these things. I'm sure that some types are just right for this particular setup, but would need a lot of experimenting to figure out.
Anyway, if anyone has more info on the original transformer, please let me know.
This is a low priority project, but I like to think about it. If I ever get around to actually making it, I'll put up the how-to info.