Look on the diagnostics page and note which one is triggering it. Then
either check or un-check it. If you use normally closed switches then you
need to un-check it.
Jim
toggle quoted message
Show quoted text
----- Original Message -----
From: "INDECO" <indeco@...>
To: <mach1mach2cnc@...>
Sent: Sunday, February 29, 2004 3:41 PM
Subject: Re: [mach1mach2cnc] can not clear external E-Stop in mach2
I did that Bob..I am running the sound logic.
When it first come up, it says limit switch triggered
Robin
----- Original Message -----
From: Robert Campbell
To: mach1mach2cnc@...
Sent: Sunday, February 29, 2004 4:34 PM
Subject: Re: [mach1mach2cnc] can not clear external E-Stop in mach2
Robin,
Make sure that you are using the Sound Logic XML file. You can download
a
copy from my web page.
Then when starting up Mach2, click on Mach2 not Mach2 Mill. Select the
Sound
Logic XML file.
This should set all your pins correctly and set the EPO setting properly
to
active low.
Bob Campbell
Bob@...
www.campbelldesigns.com
Breakout board
THC board sets
CNC router plans
Stepper Motors
----- Original Message -----
From: "INDECO" <indeco@...>
To: <mach1mach2cnc@...>
Sent: Sunday, February 29, 2004 3:28 PM
Subject: [mach1mach2cnc] can not clear external E-Stop in mach2
> Hello,
>
> I am running campbell board and i have the J-21 jumper 1&2 shorted
but I
still can not clear the E-Stop...what am I missing?
>
> Robin
>
>
>
>
>
>
>
>
> Yahoo! Groups Links
>
>
>
>
>
--------------------------------------------------------------------------
----
Yahoo! Groups Links
a.. To visit your group on the web, go to:
b.. To unsubscribe from this group, send an email to:
mach1mach2cnc-unsubscribe@...
c.. Your use of Yahoo! Groups is subject to the Yahoo! Terms of
Service.