Locked
Re: HT-37 transformer failure due to rapid STBY-->OFF-->STBY
My plan would be to replace the tube rectifiers with diodes anyway.
--
73/Rick
W4XA
__________________________________
All posts are created using OpenSuSE Leap 15.5 x64 Linux
By
Rick W7IMM
·
#30546
·
|
Locked
Re: HT-37 transformer failure due to rapid STBY-->OFF-->STBY
Tube Rectifier Compatibility Chart attached.
Paul, W9AC
By
Paul Christensen
·
#30545
·
|
Locked
Re: HT-37 transformer failure due to rapid STBY-->OFF-->STBY
To minimize Vdrop, a 5U4 can oftentimes be substituted with a 5AR4/GZ34. Maximum Ep and Ip ratings between the two are similar.
Paul, W9AC
By
Paul Christensen
·
#30544
·
|
Locked
Re: HT-37 transformer failure due to rapid STBY-->OFF-->STBY
The voltage drop afforded with certain tube rectifiers is definitely a factor for low B+ voltage levels.? It's the main problem in the Johnson Valiant.? (Low B+ should be around 300V and many
By
Rick W7IMM
·
#30543
·
|
Locked
Re: HT-37 transformer failure due to rapid STBY-->OFF-->STBY
Rick ,
Re Disc ceramic caps shorting would seem rare but you never really know what a 60+ year old part will do!
the judicious use of fuses even buried inside can mitigate a small failure from
By
don Root
·
#30542
·
|
Locked
Re: HT-37 transformer failure due to rapid STBY-->OFF-->STBY
Yeah....No kidding!
I even took it a step further and replaced the original HT-45 plate transformer (SEC voltage 6750VAC? center-tapped) with the Drake L-4PS transformer that requires a voltage
By
Rick W7IMM
·
#30541
·
Edited
|
Locked
Re: HT-37 transformer failure due to rapid STBY-->OFF-->STBY
Comments is BLUEJimLogic: Method used to arrive at the wrong conclusion, with confidence.? Murphy
By
Jim Whartenby
·
#30540
·
|
Locked
Re: HT-37 transformer failure due to rapid STBY-->OFF-->STBY
Rick, Thanks for all that historical info it all makes sense, but to answer jims specific question in a little more detail the 5volt winding floats for a few cycles and then is forced to HV by the
By
don Root
·
#30539
·
|
Locked
Re: HT-37 transformer failure due to rapid STBY-->OFF-->STBY
You're right.? The additional load due to the filament current is pretty much insignificant
HV choke input power supplies? used tube type rectifiers in a full wave CT configuration and placed high
By
Rick W7IMM
·
#30538
·
|
Locked
Re: HT-37 transformer failure due to rapid STBY-->OFF-->STBY
All ¡ has anyone physically looked at the off-on part of the Operation switch?.
At first look one might expect it to be a wafer [ poor wafer] , but the schematic of the Ht-37 seems to show that
By
don Root
·
#30536
·
|
Locked
Re: HT-37 transformer failure due to rapid STBY-->OFF-->STBY
I don't understand how changing from a vacuum tube rectifier to a solid state rectifier has a positive affect on the power transformer's reliability.? The only difference that I see is that the load
By
Jim Whartenby
·
#30535
·
|
Locked
Re: HT-37 transformer failure due to rapid STBY-->OFF-->STBY
This is a long thread, and I am very late to the party.??Maybe this has already been discussed.? HT-37 transformer failures are common due to a failure/shorting between the rectifier filament
By
hrd998cc
·
#30534
·
|
Locked
Re: HT-37 transformer failure due to rapid STBY-->OFF-->STBY
Yup! I did say that!
I was talking about Jim's mention of what a new transformer costs and I found it on Digikey! I apologize for not quoting what I was talking about!
I have to say that if the
By
Rick W7IMM
·
#30533
·
|
Locked
Re: HT-37 transformer failure due to rapid STBY-->OFF-->STBY
Rick, I began to think I would have to get on my knees¡ again and ask for forgiveness then on my last gasp of searching I found: ¡°/g/HallicraftersRadios/message/30502
At the
By
don Root
·
#30532
·
|
Locked
Re: HT-37 transformer failure due to rapid STBY-->OFF-->STBY
If only once during the application of AC power is the issue then why use an SSR at all?
The SSR forces the power transformer to see the same stress every time power is applied, the flux builds
By
Jim Whartenby
·
#30531
·
Edited
|
Locked
Re: HT-37 transformer failure due to rapid STBY-->OFF-->STBY
Maybe a momentary power failure or hit could generate a similar damaging condition.
73,
Maynard
W6PAP
By
Maynard Wright, P. E., W6PAP
·
#30530
·
|
Re: HT-44 VOX issue - Final Solution!
Great Pics
[email protected]> wrote:
By
Dave Jordan
·
#30529
·
Edited
|
Re: HT-44 VOX issue - Final Solution!
Here's a scope trace of sending three dits at around 25 wpm. Note the shortened length of the first dit and the lower output level compared to the second and third dits.
Here's how three dits look
By
Floyd - K8AC
·
#30528
·
Edited
|
Re: HT-44 rough CW note in transceive mode
This problem has been resolved. One of the things I'd been meaning to do is to install a choke in the SX-117 power supply. After installing a 5 Henry choke in the supply, this problem
By
Floyd - K8AC
·
#30527
·
|
Locked
Re: HT-37 transformer failure due to rapid STBY-->OFF-->STBY
Repeating my Feb 15 attempt to get image thru the new GIO I will delete this message if it fails
but the an other very important thing is IN THE MANUAL [ edited from the BAMA manual] ¡.
and
By
don Root
·
#30526
·
Edited
|