CHECK OUT THE WIKI The purpose of the wiki is mainly to allow you to find information on instruments, either from either
- The model number
- The function(s) listed below. Some instruments have multiple functions - for example, the 4195A is a VNA, spectrum analyzer and an impedance analyzer. Therefore the 4195A is listed in multiple categories
Please also check out HPWiki available here:
- Accessory kits - various types
- AC power analyzers - PA2201A and PA2203A
- AC power supplies 6811C, 6812C, 6813C
- Airlines
- Arbitrary waveform generators M8194A
- ھ493A, 495A
- Attenuators (optical) 8156A, 8157A, 8158B, 81566A, 81576A,
- Attenuators (RF) 8494A
- Attenuator set (500 Ω) 350C
- Attenuator set (600 Ω) 350D
- Attenuator switch driver
- Audio analyzers 8903A, 8903B, 8903E,
- Base station test sets
- Bit error rate testers (BERTs)
- Cables
- Capacitance meters U1701A, U1701B, 4272A, 4278A, 4279A
- Capacitor Bridge 4270A,
- Capacitor standards 16380A, 16380C,
- Carrier noise test setsi
- Cesium frequency standards
- Clamp ammeters
- Close field probes
- Crystal Impedance E4915A, E4916A
- Data Acquisition Systems (DAQs)
- DC power analyzers
- DC power supplies 6030A , 6031A , 6032A, 6033A, 6035A, 6131C, 6621A, 6622A, 6623A, 6624A, 6627A, 6255A, 6645A, 6671A, 6672A, 6673A, 6674A, 6675A, 62003A, 62003C, 62003E, 62004A, 62004B, 62004E, 62005A, 62005B, 62005E, 62006A, 62006B, 62006E, 62010A, 62010C, 62010E, 62012A, 62012C, 62012E, 62015A, 62015C, 62015E, 62018A, 62018C, 62018E, 62024A, 62024C, 62024E, 62028A, 62028C, 62028E, 62048A, 62048C, 62048E
- Delay lines
- Detectors
- Device current waveform analyzers
- Digital communications analyzers
- Directional couplers
- Distortion analyzers 330B, 330C, 330D, 331A, 332A, 333A, 334A, 339A, 8903A, 8903B, 8903E,
- Dynamic measurement DC source
- Electrometers
- Fading simulators
- Femto ammeters
- Filters
- Frequency counters 522B, 5342A 5343A 5352B
- Frequency standards
- Function Generators 3310A, 8165A,
- GPIB controllers, extenders, cables etc.
- GPS frequency standards
- Harmonic mixers
- High resistance meters 4339B
- High resistance meter fixtures 16008B
- HEV EV Grid Emulators and Test Systems
- In-circuit test systems
- Impedance analyzers 4195A, 4291A, 4291B, 4395A, 4396A, 4396B, 4294A, E4990A, E4991A
- Impedance Analyzer Accessories
- Impedance / Gain Phase analyzer 4194A
- Impedance Meter 4193A,
- Isolators
- LCR meters U1701A, U1701B, U1731A, U1731B, U1731C, U1732A, U1732B, U1732C, U1733C, 4191A , 4192A, 4194A, 4195A, E4196A, 4216A, 4260A, 4261A, 4262A 4263A, 4263B, 4271B, 4274A, 4275A, 4276A , 4277A, 4284A, 4285A, 4286A, 4287A, 4291A, 4291B, 4294A, 4332A, 4342A, 4395A, 4396A, 4396B, E4980A and E4980AL
- LCR meter calibration devices 16380A 42030A 42090A, 42091A and 42100A
- LCR meter accessories
- 2-Terminal BNCs.
- 4-Terminal Pair (BNC connectors)
- Cable extension 16048A, 16048D, 16048E, 16048G, 16048H
- DC current bias accessories 42841A, 42842A, 42842B, 42842C, 42843A
- DC voltage bias accessories 16065A, 16065C,
- Kelvin clips 16089A, 16089B, 16089C,16089E
- Lead Components 16047A,16047B, 16047D, 16047E
- Material 16451B, 16452A
- Probes 42941A
- SMD 16034E, 16034G, 16034H
- 2-port 16096A
- 7 mm (APC7)
- 2-Terminal BNCs.
- LCZ meters 4276A, 4277A,
- Lightwave clock / data receivers
- Lightwave converter
- Lightwave component analyzer
- Lightwave measurement system mainframes
- Lightwave polarization analyzers 8509B
- Logic analyzers
- Nemo wireless network solutions.
- Noise and interference test set
- Noise figure analyzers
- Noise sources 346A, 346B. 346C ,
- Matching pads (50 ohm to 75 ohm or similar)
- Materials test equipment
- Microwave repeaters
- Microwave downconverters 70427A
- Microwave / THz sources
- Milliammeter 428B
- Milliohm meter
- Mobile communications DC source
- Modular instruments
- AXIe
- Data acquisition (DAQ)
- USB
- PXIe
- Modulation analyzers
- Multimeters 427A, 970A
- Optical attenuators
- Optical heads
- Optical sources
- Optical spectrum analyzers
- Oscilloscopes 120A, 120AR, 120B, 122A, 130A, 130B, 130BR, 130C, 140A, 140B, 141A, 150A, 150AR, 160B, 180A, 180AR, 180CD, 181A, 181AR, 181T, 181TR, 182C, 182T, 183A, 183B, 184A, 184B, 185A, 185B, 1200A, 1200B, 1220A, 1221A, 1703A, 1707A, 1707B, 1710A, 1710B, 1715A, 1722A, 1725A, 1726A, 1740A, 1741A, 1742A, 1743A, 1744A, 1746A, 1980A, 1980B, 5403A, 6000A, 6000L, 16533A, 16534A, 54100A, 5410B, 54100C, 5100D, 54111D, 54120A, 54120B, 54200A, 54501A, 54502A, 54503A, 54504A, 54520A, 54520C, 54540A, 54540C, 54542A, 54542C, 54600B, 54601A, 54601B, 54602B, 54603B, 54645A, 54654N, 54710A, 54720A, 54750A, 54825N, E1428,
- Oven controlled crystal oscillators (OCXOs)
- Pattern generators
- PCM terminal test set
- Phase noise measurement
- Pico ammeters
- Printers 2225
- Plotters 7470A, 7475A
- Probes
- Protocol analyzers and exercisers.
- Power booster test sets
- Power meters 431A, 431B, 431C, 432A, 435A, 435B, 437B, 438A
- Power splitters
- Power supplies
- Pulse generators
- Q-meters 4342A
- Q-meter calibration inductors 16470A
- Reflection transmission test set
- Return loss module (optical)
- Relays / switches / switch matrices (optical)
- Relays / switches / switch matrices (RF)
- Resistor standards 42030Aand 42100A
- S-parameter test sets
- Scalar network analyzers
- SCSI bus preprocessor interface E2324A
- Selective level meters 3746A
- Semiconductors
- Semiconductor parameter analyzers 4145A, 4155B, 4156B,
- Signal analyzers
- Signal generators / sweep generators / signal sources / oscillators 200CD, 201B, 209A, 204D, 608A, 8165A
- Software
- Source measure units
- Spectrum analyzers 4195A,
- Switch control units
- SWR meter 415E
- Time interval counters
- Time mark generator 226A
- Timing and data state modules
- Torque wrenches
- Transmitter testers
- Trigger modules
- Ultrasound transducers
- Universal bridge 4260A, 4265A, 4265B
- Vacuum tube voltmeter 410C
- Vector Impedance Meter 4193A, 4800A, 4815A
- Vector Network Analyzers (VNAs) 4195A, 8510A, 8510B, 8510C, 8753A, 8753B, 8753C, 8753D, 8753E, 8753ES, 8752ET, 8719A, 8719B, 8719C, 8719D, 8720A, 8720B, 8720C, 8720D, 8720ES, 8722A, 8722B, 8722C, 8722D, 8722ES,
- Vector Network Analyzers (VNA) calibration kits 85032B, 85032E, 85033C, 85033D, 85033E, 85050B, 85050C, 85050D, 85052B, 85052C, 85052D, 85054A, 85054B, 85054D, 85056A
- Vector Network Analyzer (VNA) verification kits
- Vector Signal Analyzer 89650S, 89600S
- Vector voltmeters 8405A, 8508A,
- VXI mainframes 70000B, 70000C
- Waveform and function generators
- Waveguide to waveguide and waveguide to coaxial transitions.
- Wireless 58 OTA chambers
- Wireless channel emulators
- Wireless network emulators
- Wireless communication test sets
Re: Found a on line auction selling several HP items Oct 26 end date
Sort of:
"For shipping, we work with a local UPS franchise. They will pickup
your items the week following the sale and contact you directly to
discuss shipping options and costs, and then you will
By
David DiGiacomo
·
#86290
·
|
Found a on line auction selling several HP items Oct 26 end date
I was looking for some Ham equipment and found a Kansas City based Online auction listing several HP Items.
They will arrange shipping!
HP-8640B:
By
Carl Gaul
·
#86289
·
|
Re: Request for E4406A CLIPs (was Re: E4406A Input Attenuator)
Hi
There are relased clip for the rf unit and the fan controller boards.
At keysight forum it were promissed that the rest would be relased soo-so it exist at keysight!
Tony--please contact
By
hardyhansendk
·
#86288
·
|
HP 3586B LSB/USB sideband tone
I have the subject receiver and have noticed lately that the LSB has a higher pitch than the USB. I assume one of the BFO crystals has drifted in frequency. I looked at the manual and don't see an
By
Jerry Hancock
·
#86287
·
|
Re: 5342A: blown sampler?
Hi,
Your measurements with the diode mode suggest the sampler is OK, digital meters don't use the same amount of current to test resistance as older analogue meters and that's the reason you didn't
By
Gerard Brach
·
#86286
·
|
Re: 3585B Spectrum Analyzer
One thing you can try on contact fingers is a white eraser - usually works
pretty well at removing oxidation
hp_agilent_equipment@...> wrote:
By
Andrew Hakman
·
#86285
·
|
Re: 3585B Spectrum Analyzer
Hi Dave,
So far I've been using contact cleaner for the contacts and basically just giving them a bit of a rub. To the eye it all looks pretty clean but you never know.
Your experience is
By
ve3poa@...
·
#86284
·
|
Re: HP 8640B troubleshooting, no AM modulation
If you can control the output level with the Vernier knob, that eliminates many suspects, because it uses the same control paths as modulation.
Dave Wise
Sent: Tuesday, October 17, 2017 4:24 AM
To:
By
Dave Wise
·
#86283
·
|
Re: HP 8640B troubleshooting, no AM modulation
Hi Nico there are many ways of producing an external mod source. We all get used to having a standard piece of HP gear for the job. .......but for instance a comms rx with a xtal calibrator will
By
Alan Melia
·
#86282
·
|
Re: E4406A Input Attenuator
All the same, let's hope that someone will have the other schemes...
Alexander
By
Alex
·
#86281
·
|
Request for E4406A CLIPs (was Re: E4406A Input Attenuator)
Just to help clarify on Alexander's request - This is a completely different repair from the one I've been working on (still not complete unfortunately) and he's just asking for the CLIPs if anyone
By
Tony Goodhew
·
#86280
·
|
Re: E4406A Input Attenuator
Hi All.
In the continuation of the repair of our E4406.... I have a problem with the front panel control and the PS unit. The repairing experience of measurement instruments already exists, but
By
Alex
·
#86279
·
|
Re: 8901B Power level zeroisation
Just coming back to the question what does percent mean for FM?�, the manual says:
The calibration factor will be displayed as a percentage. This percentage indicates the relationship between the
By
Tony Goodhew
·
#86278
·
|
Re: 5342A: blown sampler?
Hi Tobias,
Do check out Azure, it’s a good site! I have a couple of 5342A parts units and should have a good sampler and other bits.
73,
Steve
WB0DBS
By
Steve - Home
·
#86277
·
|
Re: 8901B Power level zeroisation
Peter,
When FM Measurement is selected, the display will show peak deviation. The steps are outlined in the OP Manual under Section III Operation, Getting
By
czelusniakd
·
#86276
·
|
HP 8640B troubleshooting, no AM modulation
Needed my HP 8640B for troubleshooting some radio equipment after 2 years of not using it. Ended up with troubleshooting the HP 8640B first.
The RF output is not being modulated in AM (don't know
By
nico@...
·
#86275
·
|
Re: Plan to deep cleaning my gear
Long years ago, people at HP France used Cen Mil E dilued in water at 50% to clean the various tube equipmants where heat and consequently dust were very important . They were dried in a climatic
By
jfphp
·
#86274
·
|
Re: 5342A: blown sampler?
Hi TobiasCheck outhttp://www.azurelectronics.com/Repair%20HP%205342A%20Microwave%20Frequency.htm as it may help.RegardsSteve
By
Steve A
·
#86273
·
|
Re: 8901B Power level zeroisation
Ok, so that worked, but what does percent mean for FM? kHz deviation would be more useful.
Peter
By
Peter Gottlieb
·
#86271
·
|
Re: Plan to deep cleaning my gear
Be careful of using IPA to clean instruments. I had experienced pretty much no problems using IPA until I accidentally hit the leftmost frequency display wheel on my HP 8601A. The IPA dissolved the
By
Dave Daniel
·
#86272
·
|