CHECK OUT THE WIKI The purpose of the wiki is mainly to allow you to find information on instruments, either from either
- The model number
- The function(s) listed below. Some instruments have multiple functions - for example, the 4195A is a VNA, spectrum analyzer and an impedance analyzer. Therefore the 4195A is listed in multiple categories
Please also check out HPWiki available here:
- Accessory kits - various types
- AC power analyzers - PA2201A and PA2203A
- AC power supplies 6811C, 6812C, 6813C
- Airlines
- Arbitrary waveform generators M8194A
- Amplifiers?493A, 495A?
- Attenuators (optical) 8156A, 8157A, 8158B, 81566A, 81576A,?
- Attenuators (RF) 8494A
- Attenuator set (500 Ω) 350C
- Attenuator set (600 Ω) 350D
- Attenuator switch driver
- Audio analyzers? 8903A, 8903B, 8903E,? ?
- Base station test sets
- Bit error rate testers (BERTs)
- Cables
- Capacitance meters U1701A, U1701B, 4272A, 4278A, 4279A
- Capacitor Bridge 4270A,
- Capacitor standards 16380A, 16380C,?
- Carrier noise test setsi
- Cesium frequency standards
- Clamp ammeters
- Close field probes
- Crystal Impedance E4915A, E4916A
- Data Acquisition Systems (DAQs)
- DC power analyzers
- DC power supplies 6030A , 6031A , 6032A, 6033A, 6035A, 6131C, 6621A, 6622A, 6623A, 6624A, 6627A, 6255A, 6645A, 6671A, 6672A, 6673A, 6674A, 6675A, 62003A, 62003C, 62003E, 62004A, 62004B, 62004E, 62005A, 62005B, 62005E, 62006A, 62006B, 62006E, 62010A, 62010C, 62010E, 62012A, 62012C, 62012E, 62015A, 62015C, 62015E, 62018A, 62018C, 62018E, 62024A, 62024C, 62024E, 62028A, 62028C, 62028E, 62048A, 62048C, 62048E
- Delay lines
- Detectors
- Device current waveform analyzers
- Digital communications analyzers
- Directional couplers
- Distortion analyzers 330B, 330C, 330D, 331A, 332A, 333A, 334A, 339A, 8903A, 8903B, 8903E,???
- Dynamic measurement DC source
- Electrometers
- Fading simulators
- Femto ammeters
- Filters
- Frequency counters 522B, 5342A 5343A 5352B
- Frequency standards?
- Function Generators ? 3310A,? 8165A,
- GPIB controllers, extenders, cables etc.
- GPS frequency standards
- Harmonic mixers
- High resistance meters 4339B
- High resistance meter fixtures 16008B
- HEV EV Grid Emulators and Test Systems
- In-circuit test systems
- Impedance analyzers 4195A, 4291A, 4291B, 4395A, 4396A, 4396B, 4294A, E4990A, E4991A
- Impedance Analyzer Accessories
- Impedance / Gain Phase analyzer 4194A
- Impedance Meter 4193A,
- Isolators
- LCR meters? U1701A, U1701B, U1731A,? U1731B, U1731C, U1732A, U1732B, U1732C, U1733C, 4191A , 4192A, 4194A, 4195A, E4196A,? 4216A, 4260A, 4261A, 4262A? 4263A, 4263B, 4271B, 4274A, 4275A, 4276A , 4277A, 4284A, 4285A, 4286A, 4287A, 4291A, 4291B, 4294A, 4332A, 4342A, 4395A, 4396A, 4396B, E4980A and E4980AL
- LCR meter calibration devices? 16380A 42030A? 42090A, 42091A and 42100A
- LCR meter accessories
- 2-Terminal BNCs.
- 4-Terminal Pair (BNC connectors)
- Cable extension 16048A, 16048D, 16048E, 16048G, 16048H
- DC current bias accessories 42841A, 42842A, 42842B, 42842C, 42843A
- DC voltage bias accessories 16065A, 16065C,
- Kelvin clips 16089A, 16089B, 16089C,16089E
- Lead Components 16047A,16047B, 16047D, 16047E
- Material 16451B, 16452A
- Probes 42941A
- SMD 16034E, 16034G, 16034H
- 2-port 16096A
- 7 mm (APC7)
- 2-Terminal BNCs.
- LCZ meters? 4276A, 4277A,
- Lightwave clock / data receivers
- Lightwave converter
- Lightwave component analyzer
- Lightwave measurement system mainframes
- Lightwave polarization analyzers 8509B
- Logic analyzers
- Nemo wireless network solutions.
- Noise and interference test set
- Noise figure analyzers
- Noise sources 346A, 346B. 346C ,
- Matching pads (50 ohm to 75 ohm or similar)
- Materials test equipment
- Microwave repeaters
- Microwave downconverters 70427A
- Microwave / THz sources
- Milliammeter 428B
- Milliohm meter
- Mobile communications DC source
- Modular instruments
- AXIe
- Data acquisition (DAQ)
- USB
- PXIe
- Modulation analyzers
- Multimeters 427A, 970A
- Optical attenuators
- Optical heads
- Optical sources
- Optical spectrum analyzers
- Oscilloscopes 120A, 120AR, 120B, 122A, 130A, 130B, 130BR, 130C, 140A, 140B, 141A, 150A, 150AR, 160B, 180A, 180AR, 180CD, 181A, 181AR, 181T, 181TR, 182C, 182T, 183A, 183B, 184A, 184B, 185A, 185B, 1200A, 1200B, 1220A, 1221A, 1703A, 1707A, 1707B, 1710A, 1710B, 1715A, 1722A, 1725A, 1726A, 1740A, 1741A, 1742A, 1743A, 1744A, 1746A, 1980A, 1980B, 5403A, 6000A, 6000L, 16533A, 16534A, 54100A, 5410B, 54100C, 5100D, 54111D, 54120A, 54120B, 54200A, 54501A, 54502A, 54503A, 54504A, 54520A, 54520C, 54540A, 54540C, 54542A, 54542C, 54600B, 54601A, 54601B, 54602B, 54603B,? 54645A, 54654N, 54710A, 54720A, 54750A, 54825N, E1428,?
- Oven controlled crystal oscillators (OCXOs)
- Pattern generators
- PCM terminal test set
- Phase noise measurement
- Pico ammeters
- Printers 2225
- Plotters 7470A, 7475A?
- Probes
- Protocol analyzers and exercisers.
- Power booster test sets
- Power meters 431A, 431B, 431C, 432A, 435A, 435B, 437B, 438A
- Power splitters
- Power supplies
- Pulse generators
- Q-meters 4342A?
- Q-meter calibration inductors 16470A
- Reflection transmission test set
- Return loss module (optical)
- Relays / switches / switch matrices (optical)
- Relays / switches / switch matrices (RF)
- Resistor standards 42030A?and 42100A
- S-parameter test sets
- Scalar network analyzers
- SCSI bus preprocessor interface E2324A
- Selective level meters 3746A
- Semiconductors
- Semiconductor parameter analyzers 4145A, 4155B, 4156B,
- Signal analyzers
- Signal generators / sweep generators / signal sources / oscillators 200CD, 201B, 209A, 204D,? 608A,? 8165A
- Software
- Source measure units
- Spectrum analyzers 4195A,???
- Switch control units
- SWR meter 415E?
- Time interval? counters
- Time mark generator 226A
- Timing and data state modules
- Torque wrenches
- Transmitter testers
- Trigger modules
- Ultrasound transducers
- Universal bridge? 4260A, 4265A, 4265B?
- Vacuum tube voltmeter 410C
- Vector Impedance Meter 4193A, 4800A, 4815A
- Vector Network Analyzers (VNAs) 4195A,? 8510A, 8510B, 8510C, 8753A, 8753B, 8753C, 8753D, 8753E, 8753ES, 8752ET, 8719A, 8719B, 8719C, 8719D, 8720A, 8720B, 8720C, 8720D, 8720ES, 8722A, 8722B, 8722C, 8722D, 8722ES,
- Vector Network Analyzers (VNA) calibration kits 85032B, 85032E, 85033C, 85033D, 85033E, 85050B, 85050C, 85050D, 85052B, 85052C, 85052D, 85054A, 85054B, 85054D, 85056A
- Vector Network Analyzer (VNA) verification kits
- Vector Signal Analyzer 89650S, 89600S
- Vector voltmeters 8405A, 8508A,
- VXI mainframes 70000B, 70000C
- Waveform and function generators
- Waveguide to waveguide and waveguide to coaxial transitions.
- Wireless 58 OTA chambers
- Wireless channel emulators
- Wireless network emulators
- Wireless communication test sets
?
Re: Introduction
Hi Robert,
I got out the 140A and found it to not be worth fooling with. The top, bottom, and one side cover are missing along with both handles. It looks like it was being used for parts to repair
By
Skip
·
#259
·
|
1725A
hi all
looking for replacement timebase switch inserts
analog,sweepdelay and main timebase
(the black switch contact assembly with the contacts that break off
all the time)
any idears
regards
By
bebaynes <bebaynes@...>
·
#258
·
|
Chicago - vintage test gear sale
I've sen this info info on some other lists-
not seen it here as yet.
Lots of older HP stuff in the pix.
Saturday May 22, 2004 from 9 AM to 2 PM
Details and map
By
Dave Brown <tractorb@...>
·
#257
·
|
Re: hp 5100A /5110A synth set
Hi:
I joined this group on the 17th and asked for a daily digest, but none
have arrived, so have missed a few postings.
I repaired my synth many years ago by replacing the SRD with the
biggest
By
Brooke Clarke
·
#256
·
|
Re: hp 5100A /5110A synth set
<morriso@v...> wrote:
Hi Morris,
i need your adress.
please mail it to me to
dj0ud at web dot de (at=@; dot =.)
Jorgen
By
Jorgen Lund-Nielsen
·
#255
·
|
Re: hp 5100A /5110A synth set
By
Morris Odell <morriso@...>
·
#254
·
|
Re: hp 5100A /5110A synth set
<morriso@v...> wrote:
Because of it hasn't to be a microwave SRD (as in the most other cases
of SRD-use) i think it is possible to substitute it with other types
of diodes which also "snap", but
By
Jorgen Lund-Nielsen
·
#253
·
|
Re: follow-up - HP 3439A
The service manual arrived today and it answered my question. The
unit must be zeroed each time it is turned on.
Thanks
BL
<computeruser@s...> wrote:
By
computeruser04 <computeruser@...>
·
#252
·
|
Re: hp 5100A /5110A synth set
Well, no so... at least I recalled your message was somewhere in the pile of unanswered ones ;-)!
Sorry for the delay!
Regards,
JOSE
PS to BG: I think I will get the Eddy
By
Jose V. Gavila <eb5agv@...>
·
#251
·
|
Re: hp 5100A /5110A synth set
By
Morris Odell <morriso@...>
·
#250
·
|
Re: hp 5100A /5110A synth set
By
Brian Goldsmith <brian.goldsmith@...>
·
#249
·
|
Re: Introduction
Hi Robert,
I will be glad to send you pictures. I have so many things going on right now that I do tend to get behind or forget. If you have not heard from me in a week, send me a reminder
By
Skip
·
#248
·
|
HP 4260 Thanks for Help
Hello again,
I have already received a number of replies about my sick 4260A.
Thanks to the group for their efforts and to the individuals for
trying to obtain parts or another unit for me. Being
By
r_j_shehan <r_j_shehan@...>
·
#247
·
|
hp 61015a counter
Looking for manual or any information on this counter,
By
michael Smith <mtmps@...>
·
#246
·
|
Re: hp 5100A /5110A synth set
By
Morris Odell <morriso@...>
·
#245
·
|
Re: Introduction
Hello Jack.
Thank you for getting back to me. I could be interested in the 140A and also the 851B. Is there a possibility that you could send some photos of both? When your time permits please let me
By
Robert Middleton <romhifi@...>
·
#244
·
|
Re: HP 4260A Parts needed
Rod,
Welcome to the hp_agilent_equipment group!
If you happen to know anyone who lives near Norfolk, Virginia, the following gov't auction lot might be of particular
By
Thomas P. Gootee
·
#242
·
|
Re: Introduction
Sorry for the re-post. I had the wrong "Subject" line, the first time.
----------
Sent: Monday, May 17, 2004 10:22 AM
To: 'hp_agilent_equipment@...'
Subject: RE:
By
Thomas P. Gootee
·
#243
·
|
Re: Digest Number 101
Jack,
I have the military model designation cross-references for most or all of the equipment on your list, which I will email to you.
Even better, I have spent a LOT of time ferreting-out any
By
Thomas P. Gootee
·
#241
·
|
Re: hp 5100A /5110A synth set
Hello Morris!
In the Synthesizer Driver,
there is a step recovery comb generator which was driven by the 1MHz
Signal. From those comb generator the ouput was filtered through a
lot of filtersbanks to
By
Jorgen Lund-Nielsen
·
#240
·
|