Re: HP 3325A Phase noise (and reference clock) as discussed in CuriousMarc's video of Soyuz Clock, Part 6
Trying to compare generators with all the variables that affect PN can drive you crazy, but would be worthwhile. I did tests on a bunch of PTS synthesizers and one of them included a comparison of
By
John Ackermann N8UR
·
#104962
·
|
Re: HP 3325A Phase noise (and reference clock) as discussed in CuriousMarc's video of Soyuz Clock, Part 6
Very interesting John. Actually, I am surprised as to how good it is. Although, since the OCXO is also at 10 MHz, it would be more interesting to see it at some random frequency. Maybe as compared to
By
Mike Feher
·
#104961
·
|
Re: HP 3325A Phase noise (and reference clock) as discussed in CuriousMarc's video of Soyuz Clock, Part 6
Hi John, Thanks for that, very enlightening! Raymond
By
Raymond Domp Frank
·
#104960
·
|
Re: HP 3325A Phase noise (and reference clock) as discussed in CuriousMarc's video of Soyuz Clock, Part 6
I should qualify that -- dramatic improvement at low offsets. More than about 10 Hz from the carrier, the results were the same with either reference.
By
John Ackermann N8UR
·
#104959
·
|
Re: HP 3325A Phase noise (and reference clock) as discussed in CuriousMarc's video of Soyuz Clock, Part 6
Several years ago I did phase noise measurements on a 3325B. The results are here: https://febo.com/pages/hp3325b/ The unit had the standard (not high-stability) oscillator and my measurements showed
By
John Ackermann N8UR
·
#104958
·
|
Re: HP 3325A Phase noise (and reference clock) as discussed in CuriousMarc's video of Soyuz Clock, Part 6
Hi Szabolcs, Only now it occurs to me that Option 001 is only exactly like the Options 001 in so many HP instruments: High Stability Oscillator (OCXO)! Until now I thought that it (also) contained
By
Raymond Domp Frank
·
#104957
·
|
Re: HP 334A Balance Pots
Just as a slight follow-up, it occurred to me that if this pot does go bad, I can replace the plastic resistive component as well as the wiper with parts from a NEW or NOS pot from the same series
By
n4buq
·
#104956
·
|
5335A keyboard LED interesting thing
Hi, Sorry if it is know, but it is new to me. While fixing the LED in one of the keys of my 5335A, I have stumbled upon some interesting thing. All keys have LEDs in them, even those where the keycap
By
Szabolcs Szigeti
·
#104955
·
|
Re: Application Note 122: EMI Measurement Procedure
They are both ¡°EMI Measurement Procedure¡±, but have different subtitles. See http://hpmemoryproject.org/ressources/resrc_an_02.htm DaveD
By
Dave Daniel
·
#104954
·
|
Re: HP 3325A Phase noise (and reference clock) as discussed in CuriousMarc's video of Soyuz Clock, Part 6
Hi, Yes, I somehow expected that without the OCXO option there isn't much point in specifying phase noise. At least it wouldn't be any stellar value anyway. The good news is that you can feed it any
By
Szabolcs Szigeti
·
#104953
·
|
Re: Application Note 122: EMI Measurement Procedure
Hi, I have AN142 which goes by the same name. Are you sure about the number? Richard
By
Richard Katezansky
·
#104952
·
|
Re: HP 8920A spectrum analyser amplitude calibration
Hi Colin Having checked the Agilent specifications for a 8920A RF power meter accuracy is plus or minus 10% of reading. Spectrum analyser is plus or minus 2.5dB. Looks like your 8920A is almost in
By
george edmonds
·
#104951
·
|
Re: hp8350b/hp83595a front panel mod
Hi Jan, The semi-rigid is standard .141 with precision stainless steel SMA connectors. It is L-shaped with a bit of an offset in the leg that goes to the front panel connector: Please note that the
By
Steve - Home
·
#104950
·
|
Re: HP 8920A spectrum analyser amplitude calibration
Gem! Thank you. Colin
By
Colin Smithers
·
#104949
·
|
Re: HP 3325A Phase noise (and reference clock) as discussed in CuriousMarc's video of Soyuz Clock, Part 6
Hi Szabolcs, Thanks for your reaction and pointer. I have been able to download the 3325B service manual you refer to, from the Agilent website, no problem... At least now I've got some numbers re.
By
Raymond Domp Frank
·
#104948
·
|
Re: HP 8920A spectrum analyser amplitude calibration
you should be ble to save the instrument state with the label "POWERON" to restore that atuomatically
By
John Yelmgren
·
#104947
·
|
Re: HP 8920A spectrum analyser amplitude calibration
Temporary fix All, Based on some thoughts delivered by this thread I have found a temporary fix, but it is really only that: - Set SA working - Inject known power into Ant port - Set to 1dB/div and
By
Colin Smithers
·
#104946
·
|
Re: HP 8920A spectrum analyser amplitude calibration
I second that. The Marconi 2945 service monitor is some 25 years old but very good. It has served me well over the years. Jos PA0AMX
By
Jos Raven PA0AMX
·
#104945
·
|
Re: HP 3325A Phase noise (and reference clock) as discussed in CuriousMarc's video of Soyuz Clock, Part 6
Hi, There is a version of the 3325B service manual, which has some service notes and other documents inside. It used to be available at Keysight's web page, I can't find it now there, but I have it
By
Szabolcs Szigeti
·
#104944
·
|
Re: WTB: 3467A Printer module.
You may consider signing up with?Shipito | Shop In The US & Ship Anywhere | Free US Address?They will prov | | | | Shipito | Shop In The US & Ship Anywhere | Free US Address Shipito offers fast,
By
Harke Smits
·