Keyboard Shortcuts
Likes
- HP-Agilent-Keysight-Equipment
- Messages
Search
CHECK OUT THE WIKI The purpose of the wiki is mainly to allow you to find information on instruments, either from either
- The model number
- The function(s) listed below. Some instruments have multiple functions - for example, the 4195A is a VNA, spectrum analyzer and an impedance analyzer. Therefore the 4195A is listed in multiple categories
Please also check out HPWiki available here:
- Accessory kits - various types
- AC power analyzers - PA2201A and PA2203A
- AC power supplies 6811C, 6812C, 6813C
- Airlines
- Arbitrary waveform generators M8194A
- Amplifiers?493A, 495A?
- Attenuators (optical) 8156A, 8157A, 8158B, 81566A, 81576A,?
- Attenuators (RF) 8494A
- Attenuator set (500 Ω) 350C
- Attenuator set (600 Ω) 350D
- Attenuator switch driver
- Audio analyzers? 8903A, 8903B, 8903E,? ?
- Base station test sets
- Bit error rate testers (BERTs)
- Cables
- Capacitance meters U1701A, U1701B, 4272A, 4278A, 4279A
- Capacitor Bridge 4270A,
- Capacitor standards 16380A, 16380C,?
- Carrier noise test setsi
- Cesium frequency standards
- Clamp ammeters
- Close field probes
- Crystal Impedance E4915A, E4916A
- Data Acquisition Systems (DAQs)
- DC power analyzers
- DC power supplies 6030A , 6031A , 6032A, 6033A, 6035A, 6131C, 6621A, 6622A, 6623A, 6624A, 6627A, 6255A, 6645A, 6671A, 6672A, 6673A, 6674A, 6675A, 62003A, 62003C, 62003E, 62004A, 62004B, 62004E, 62005A, 62005B, 62005E, 62006A, 62006B, 62006E, 62010A, 62010C, 62010E, 62012A, 62012C, 62012E, 62015A, 62015C, 62015E, 62018A, 62018C, 62018E, 62024A, 62024C, 62024E, 62028A, 62028C, 62028E, 62048A, 62048C, 62048E
- Delay lines
- Detectors
- Device current waveform analyzers
- Digital communications analyzers
- Directional couplers
- Distortion analyzers 330B, 330C, 330D, 331A, 332A, 333A, 334A, 339A, 8903A, 8903B, 8903E,???
- Dynamic measurement DC source
- Electrometers
- Fading simulators
- Femto ammeters
- Filters
- Frequency counters 522B, 5342A 5343A 5352B
- Frequency standards?
- Function Generators ? 3310A,? 8165A,
- GPIB controllers, extenders, cables etc.
- GPS frequency standards
- Harmonic mixers
- High resistance meters 4339B
- High resistance meter fixtures 16008B
- HEV EV Grid Emulators and Test Systems
- In-circuit test systems
- Impedance analyzers 4195A, 4291A, 4291B, 4395A, 4396A, 4396B, 4294A, E4990A, E4991A
- Impedance Analyzer Accessories
- Impedance / Gain Phase analyzer 4194A
- Impedance Meter 4193A,
- Isolators
- LCR meters? U1701A, U1701B, U1731A,? U1731B, U1731C, U1732A, U1732B, U1732C, U1733C, 4191A , 4192A, 4194A, 4195A, E4196A,? 4216A, 4260A, 4261A, 4262A? 4263A, 4263B, 4271B, 4274A, 4275A, 4276A , 4277A, 4284A, 4285A, 4286A, 4287A, 4291A, 4291B, 4294A, 4332A, 4342A, 4395A, 4396A, 4396B, E4980A and E4980AL
- LCR meter calibration devices? 16380A 42030A? 42090A, 42091A and 42100A
- LCR meter accessories
- 2-Terminal BNCs.
- 4-Terminal Pair (BNC connectors)
- Cable extension 16048A, 16048D, 16048E, 16048G, 16048H
- DC current bias accessories 42841A, 42842A, 42842B, 42842C, 42843A
- DC voltage bias accessories 16065A, 16065C,
- Kelvin clips 16089A, 16089B, 16089C,16089E
- Lead Components 16047A,16047B, 16047D, 16047E
- Material 16451B, 16452A
- Probes 42941A
- SMD 16034E, 16034G, 16034H
- 2-port 16096A
- 7 mm (APC7)
- 2-Terminal BNCs.
- LCZ meters? 4276A, 4277A,
- Lightwave clock / data receivers
- Lightwave converter
- Lightwave component analyzer
- Lightwave measurement system mainframes
- Lightwave polarization analyzers 8509B
- Logic analyzers
- Nemo wireless network solutions.
- Noise and interference test set
- Noise figure analyzers
- Noise sources 346A, 346B. 346C ,
- Matching pads (50 ohm to 75 ohm or similar)
- Materials test equipment
- Microwave repeaters
- Microwave downconverters 70427A
- Microwave / THz sources
- Milliammeter 428B
- Milliohm meter
- Mobile communications DC source
- Modular instruments
- AXIe
- Data acquisition (DAQ)
- USB
- PXIe
- Modulation analyzers
- Multimeters 427A, 970A
- Optical attenuators
- Optical heads
- Optical sources
- Optical spectrum analyzers
- Oscilloscopes 120A, 120AR, 120B, 122A, 130A, 130B, 130BR, 130C, 140A, 140B, 141A, 150A, 150AR, 160B, 180A, 180AR, 180CD, 181A, 181AR, 181T, 181TR, 182C, 182T, 183A, 183B, 184A, 184B, 185A, 185B, 1200A, 1200B, 1220A, 1221A, 1703A, 1707A, 1707B, 1710A, 1710B, 1715A, 1722A, 1725A, 1726A, 1740A, 1741A, 1742A, 1743A, 1744A, 1746A, 1980A, 1980B, 5403A, 6000A, 6000L, 16533A, 16534A, 54100A, 5410B, 54100C, 5100D, 54111D, 54120A, 54120B, 54200A, 54501A, 54502A, 54503A, 54504A, 54520A, 54520C, 54540A, 54540C, 54542A, 54542C, 54600B, 54601A, 54601B, 54602B, 54603B,? 54645A, 54654N, 54710A, 54720A, 54750A, 54825N, E1428,?
- Oven controlled crystal oscillators (OCXOs)
- Pattern generators
- PCM terminal test set
- Phase noise measurement
- Pico ammeters
- Printers 2225
- Plotters 7470A, 7475A?
- Probes
- Protocol analyzers and exercisers.
- Power booster test sets
- Power meters 431A, 431B, 431C, 432A, 435A, 435B, 437B, 438A
- Power splitters
- Power supplies
- Pulse generators
- Q-meters 4342A?
- Q-meter calibration inductors 16470A
- Reflection transmission test set
- Return loss module (optical)
- Relays / switches / switch matrices (optical)
- Relays / switches / switch matrices (RF)
- Resistor standards 42030A?and 42100A
- S-parameter test sets
- Scalar network analyzers
- SCSI bus preprocessor interface E2324A
- Selective level meters 3746A
- Semiconductors
- Semiconductor parameter analyzers 4145A, 4155B, 4156B,
- Signal analyzers
- Signal generators / sweep generators / signal sources / oscillators 200CD, 201B, 209A, 204D,? 608A,? 8165A
- Software
- Source measure units
- Spectrum analyzers 4195A,???
- Switch control units
- SWR meter 415E?
- Time interval? counters
- Time mark generator 226A
- Timing and data state modules
- Torque wrenches
- Transmitter testers
- Trigger modules
- Ultrasound transducers
- Universal bridge? 4260A, 4265A, 4265B?
- Vacuum tube voltmeter 410C
- Vector Impedance Meter 4193A, 4800A, 4815A
- Vector Network Analyzers (VNAs) 4195A,? 8510A, 8510B, 8510C, 8753A, 8753B, 8753C, 8753D, 8753E, 8753ES, 8752ET, 8719A, 8719B, 8719C, 8719D, 8720A, 8720B, 8720C, 8720D, 8720ES, 8722A, 8722B, 8722C, 8722D, 8722ES,
- Vector Network Analyzers (VNA) calibration kits 85032B, 85032E, 85033C, 85033D, 85033E, 85050B, 85050C, 85050D, 85052B, 85052C, 85052D, 85054A, 85054B, 85054D, 85056A
- Vector Network Analyzer (VNA) verification kits
- Vector Signal Analyzer 89650S, 89600S
- Vector voltmeters 8405A, 8508A,
- VXI mainframes 70000B, 70000C
- Waveform and function generators
- Waveguide to waveguide and waveguide to coaxial transitions.
- Wireless 58 OTA chambers
- Wireless channel emulators
- Wireless network emulators
- Wireless communication test sets
?
Re: microscope / high magnification camera options for soldering, faults, and other examinations/inspections
I use an American Optical (because it was cheap) and found a nice heavy stand to hold it up.? I have a fiber optic ring light on the microscope.
toggle quoted message
Show quoted text
I find that an auxiliary light can help to illuminate from the side as well. I would build a board holder that allows you to position any part of a board under the microscope without moving the microscope. How complicated you make that little board holder is up to you. Maybe move manually and lock into place. if you were building boards by hand, and using EAGLE, then I can show you a program that models the PC board in OpenSCAD.? That same parsing routine can find the XY of any part. that might help a bit. Ideally, you want to move the board in X and Y, then rotate for the best soldering angle. Harvey On 3/17/2025 2:59 PM, Radu Bogdan Dicher via groups.io wrote:
|
Re: Threads for screws on 8656 Siggen
toggle quoted message
Show quoted text
Maybe I have the same problem as the 8656: the cover screws for the 8643 is NOT 6-32 (USA, national coarse), nor is it 6-40 (USA, national fine). The diameter is very close to USA #6, a finer thread than 32 threads per inch. It has to be some metric size that the local specialty guy did not recognize. |
Re: microscope / high magnification camera options for soldering, faults, and other examinations/inspections
Thank you again all - really thoughtful and comprehensive input.? I may be able to buy a Nikon SMZ645 for $250-300 or so. I wonder what you all think about that opportunity. This would come with what seems to be the C-PS160 stand (I think?...) and some sort of sizable horizontal arm - overall, it seems to be able to reach pretty freely around maybe as much as a quarter or so of my bench. This is by eyeballing pictures I received etc. Ideally, this would have a bit of autonomy around the bench, but maybe I'm asking too much from an optical microscope and should just also have a small digital wifi microscope for other inspections and other examinations,?blasting?what it sees on a large screen. I have duly registered the advice this far to focus on an optical stereo microscope - it's just that I think a small battery powered wifi microscope would add some additional functionality to the bench.? My eyes have a bunch of issues, including the fact that they're very dissimilar left to?right. I can't imagine this not being a "glasses on" type of situation. There'll be a zillion different?lens between my eyes and the subject of magnification!...?? Radu.? On Mon, Mar 17, 2025 at 6:27?PM Steve Hendrix via <SteveHx=[email protected]> wrote: On 2025-03-17 2:59 PM, Radu Bogdan Dicher via wrote: |
Re: microscope / high magnification camera options for soldering, faults, and other examinations/inspections
On 2025-03-17 2:59 PM, Radu Bogdan Dicher via groups.io wrote:
Probably a stupid question, but I know nothing on the "stereo microscope" topic - are these working well for people wearing glasses?I personally wear bifocals. I take them off when using the microscope, to allow my eyes to get close enough to see the full field of view. It just shift the optimum focus for me, from what's optimum for my tech. Not a big issue. That approach does not, of course compensate for astigmatism, so if you have significant astigmatism you might do better with glasses on. Steve Hendrix |
Re: Threads for screws on 8656 Siggen
From my long ago youth futzing around in a tool and die shop, I recall, there is also a (rarely found) 5-40 ANSI thread
toggle quoted message
Show quoted text
Sure enough: -Dale On Mar 17, 2025, at 19:14, Don Bitters via groups.io <donbitters@...> wrote: |
Re: 3" disks for 8566A/B, 8568A/B on HP 9000 Series 200 Computers - Any interest in images?
Hi Ulf,
toggle quoted message
Show quoted text
Thanks for the disks. If you find other similar disks please upload them to the group files section. 73, Razvan On 17/03/2025 13:14, Ulf Kylenfall via groups.io wrote:
I used an old 9122 Disk drive. Was able to read the disks and uploaded |
Re: microscope / high magnification camera options for soldering, faults, and other examinations/inspections
It's interesting to read the various posts.
I possess both video microscopes and binocular styles as well depending upon the work being done. Out of all I usually grab a video unit first off. It is nice to be able to have items that you need to grab when working by simply glancing down rather than having to pull yourself away from eyepieces every time. And views through eyepieces sometimes is like looking through a tunnel with my advancing optical issues. I also find that working with SMT technology you are viewing a planar work surface with both approaches anyway. Working with a display screen takes a bit of practice to gain the experience in doing so. I have had no problems when working with SMT components down to 0201, TSSOP, etc. size. As I commented to a person earlier today: It's all the personal preference of each user. Some people cannot live with a particular approach while others have no issue with it. Greg |
Re: microscope / high magnification camera options for soldering, faults, and other examinations/inspections
I do not recommend the digital microscopes, because they don't provide
stereo vision, which is really important when working on SMT components. ?
I've been using stereo microscopes for at least 20 years, and have tried
several. I am typically soldering 0603 passives, SOT-23, and QFN parts
with 0.5 mm pad pitch. Sometimes I am working with 0402 parts.
?
My current favorite setup is an AmScope boom arm Stereo Zoom.
Boom reach:? 24" , very heavy base
Magnification Range:?? 0.7 to 4.5
?
Eye pieces: WF10X/20 (Wide field, can be used with glasses, but I always take
?????????????????? my glasses (reading) off as I find it more comfortable)
?
Must have option: Barlow lens with a magnification of 0.5? . This doubles the
?????????????????? working distance from the bottom lens (Barlow) to the PCB, which
?????????????????? is really nice when you want to hold the soldering iron near vertical.
?????????????????? It also helps when the head is raised about 4", as it lets you hold
?????????????????? the board at an angle to view components and joints at other than
?????????????????? vertical only. Other Barlow magnifications are available, those that
?????????????????? increase magnification will reduce working distance.
?
So the stack up is (0.7 to 4.5) x 10 x 0.5 gives magnification of 3.5 to 22.5? .
I also have some x20 eyepieces but I rarely use them. If I remove the Barlow
lens, then my max magnification is 20 x 4.5 = 90 , but this has very limited
depth of field.
?
With regard to lighting, I originally had fluorescent ring lights, but I found the
light was not bright enough, and there was also a continuous buzz from the
power supply. 20 years ago, high intensity LED ring lights were not an option.
About 10 years ago I designed my own LED ring light with 30 high intensity
SMT white LEDs, and a 32V power supply. ?
Unless you are planning to make youtube videos, don't pay extra for a
trinocular microscope. And if you do get a trinocular you will be real
disappointed to discover that when you enable the camera optical path,
you lose the stereo vision path. I did a quick scan of Amazon, and it seems
all the boom arm stereo microscopes are trinocular.
?
Expect to pay between $600 and $1000, for an investment in your eyes
that will last a life time.
?
Some people noted that Vision Engineering Mantis is an option, although
some issues are also described above. I have one of the older models with
x3 and x10 objective lenses, and I hate it. It is bulky, hard to focus, does
not have zoom capability, and the lighting is poor. I never use it any more.
?
In other news, I strongly recommend Metcal soldering irons, with the
STTC-1xx series cartridges. STTC-106 for 0603 , 0402, SOT-23, and QFN
parts.? STTC-144 is also nice for these parts (has a bent tip). STTC-135 for
through hole parts, and STTC-117 for plumbing and ground planes.
ROHS compliant solder is Kester 24-7068-7603
?
?
Cheers,
Philip ? |
Re: microscope / high magnification camera options for soldering, faults, and other examinations/inspections
Radu, I'm a little late jumping in, but here goes. I have a couple of issues that impact my bench work. First is that I have vision problems and need magnification to do even basic work. Second is that a year or so ago I developed some neck/shoulder problems that made hunching over to solder painful after a short time at the bench.
toggle quoted message
Show quoted text
For years I'd been using a cheap Chinese stereo microscope and was very happy with that, until the shoulder thing made using it difficult. I decided to switch to a digital microscope with a 24 inch monitor mounted off the back of the bench. I got one of the better-rated Chinese ones from Amazon for, IIRC, around $400 for the basic kit. I'm still getting used to it, but here are a few thoughts: 1. Not having stereo vision makes soldering very different, but you do get used to it, and pretty quickly. It's not the problem I thought it would be, but it still requires adaptation. 2. Most of the moderately priced digital units don't have a "true" zoom in that the focus (or inverse, working distance) shifts as the magnification changes. This is a real pain when you want to zoom in to inspect something. Were I to do it again, I'd spend a couple hundred more if necessary to get a true zoom with stable focus. 3. With the lack of 3-D, lighting becomes very important. The ring light around the lens is good most of the time, but having a light that you can shine from an angle sometimes makes a tremendous difference. I haven't tried it yet, but Dave at eevblog did a video showing how much difference using polarized light can make, too. 4. Be aware that there are a multitude of different mounting tube and fitting sizes used on microscopes, both analog and digital. I wasted a bunch of time and money on pieces that didn't fit together. (I was trying to come up with a wall-mount so that vibrations on the bench wouldn't shake the image. I'm still not there yet.) Hope this helps. John ---- On 3/17/25 14:59, Radu Bogdan Dicher via groups.io wrote:
Thank you all, great input. |
Re: microscope / high magnification camera options for soldering, faults, and other examinations/inspections
Thank you all, great input. On Mon, Mar 17, 2025, 10:29 AM John Griessen via <john=[email protected]> wrote: On 3/17/25 07:59, Dave McGuire via wrote: |
Re: Threads for screws on 8656 Siggen
Maybe I have the same problem as the 8656: the cover screws for the 8643 is NOT 6-32 (USA, national coarse), nor is it 6-40 (USA, national fine). The diameter is very close to USA #6, a finer thread than 32 threads per inch. It has to be some metric size that the local specialty guy did not recognize.
toggle quoted message
Show quoted text
Thank you Goran for the idea of looking at the parts list. I will try to find an 8643 manual on line somewhere and see what it says. Bill On 3/17/2025 5:17 AM, G?ran Krusell via groups.io wrote:
p. 6-36. 4 * MP101, 6-32. |
Re: Threads for screws on 8656 Siggen
toggle quoted message
Show quoted text
From: [email protected] <[email protected]> on behalf of Bill Carver via groups.io <bill@...>
Sent: Monday, March 17, 2025 1:50 PM To: [email protected] <[email protected]> Subject: Re: [HP-Agilent-Keysight-equipment] Threads for screws on 8656 Siggen ?
I went to a hardware specialty store with one of the Torx screws from
the 8643. They said it was not a metric diameter. Nor was it 32 threads per inch, a US "coarse" thread. They said it look like it was a US? #6-40, an uncommon but US-standard "fine thread". Today I bought a baggie with 20 and.......it appears to be close to the right diameter but it is not 40 threads per inch. I have not figured out what the thread is, but it is NOT a US fine threaded, 6-40. Bill On 3/17/2025 3:54 AM, Steve Hendrix wrote: > On 2025-03-17 12:25 AM, Wayne Eckert via groups.io wrote: >> Hi can someone tell me what thread the screws are that hold the back >> panel on? HP8656. I am assuming they are 5/32 as 3mm and 4mm metric >> are either too small or too big. or wrong thread > > There's also a 3.5mm standard thread, used on IEEE-488 connectors, > that might be a possibility. > > Steve Hendrix > > > > > > |
Re: Threads for screws on 8656 Siggen
I went to a hardware specialty store with one of the Torx screws from the 8643. They said it was not a metric diameter. Nor was it 32 threads per inch, a US "coarse" thread. They said it look like it was a US? #6-40, an uncommon but US-standard "fine thread". Today I bought a baggie with 20 and.......it appears to be close to the right diameter but it is not 40 threads per inch.
toggle quoted message
Show quoted text
I have not figured out what the thread is, but it is NOT a US fine threaded, 6-40. Bill On 3/17/2025 3:54 AM, Steve Hendrix wrote:
On 2025-03-17 12:25 AM, Wayne Eckert via groups.io wrote:Hi can someone tell me what thread the screws are that hold the back panel on? HP8656. I am assuming they are 5/32 as 3mm and 4mm metric are either too small or too big. or wrong threadThere's also a 3.5mm standard thread, used on IEEE-488 connectors, that might be a possibility. |
Re: E5052A Power On Test (3.3V Bus Supply)
Thanks.
I had some free time today and experimented with a discretely designed gain block in place of the MMIC. I think I'm hitting the limits of the E5052A now but I managed -170dBc/Hz at 10kHz offset and about -178dBc/Hz for the far out noise floor. I couldn't improve on about -160dBc/Hz at 1 kHz offset. This is a slight improvement but I think the E5052A is becoming the weak link. I've seen the PN2060C phase noise analyser by BG6KHC on qsl and this looks to be an interesting piece of equipment for $849.? ? I've linked to it below. ? Welcome to BG6KHC’s website ? Has anyone got any experience of this device? |
Re: microscope / high magnification camera options for soldering, faults, and other examinations/inspections
On 3/17/25 07:59, Dave McGuire via groups.io wrote:
On 3/17/25 00:02, Radu Bogdan Dicher via groups.io wrote:Hi Radu,Having done enough (red) eye cracking smd soldering jobs or inspections in case of suspected failure (cold joints, etc.), I've decided to invest a bit on a better optical setup.? The Mantis by Vision Engineering. I've got Greenough scopes (binocular) by Olympus and Vision Engineering (precursor to Mantis), and fiber light rings and sources to sell. The Vision Engineering ones are kind of large, but trying an Olympus Greenough would be painless -- you could return it if not liking it. When I assemble SMT boards I use a Greenough on a boom that lets me move with fine dials in X and Y (and of course Z for focus). I've also tried the Vision Engineering and it would probably be a speedup tool, but Ive not afforded enough bench top space to use one effectively yet. Also have Nikon SMZ-7 and a Vision Engineering Greenough for sale. Booms to hold them are super heavy, so looking locally makes the most sense. I agree with Dave, that if you want to do prototypes your speed and quality will improve drastically with stereo vision -- it puts your "there" in the micro world... Also you will notice more since flat view onscreen doesn't translate to 3D in your mind well. The large screens might be OK for some things, but not for active seeing when looking for tiny cracks, missing solder, adequate solder paste, etc. Now to get busy cleaning and photographing the ones I mentioned... -- John Griessen Albuquerque NM |
Re: 3" disks for 8566A/B, 8568A/B on HP 9000 Series 200 Computers - Any interest in images?
开云体育Hello Ulf, The HP "ASCII" files can be converted to a Windows txt form with HPDIR. I wrote some time ago a small Windows utility that is doing this, also in batch mode (multiple files at once). I attached the 3 ASCII files from your first disk 08568-10004 (since they are small). In case it is interesting, the small program is available (I just don't want to fill the storage space of the group). To save the binary HP PROG files, you have to load them in a HP
RM Basic, and save them as ASCII (which can be converted to
Windows txt format as above). This can be also done using Olivier
Smet's? HP98x6 emulator and running a HP RM Basic on it on a
Windows machine. The attached pdf file is describing the step by
step procedure. I will check during the week at least one-two of your PROG files
for their integrity. BR, George/Gyorgy On 3/17/2025 2:14 PM, Ulf Kylenfall via
groups.io wrote:
-- Gy?rgy Albert Mob +40-722-304534 COPYRIGHT.txt
COPYRIGHT.txt
TEXT_68.txt
TEXT_68.txt
TEXT_6836.txt
TEXT_6836.txt
HP Emulator guide_V1.2.pdf
HP Emulator guide_V1.2.pdf
|
Re: microscope / high magnification camera options for soldering, faults, and other examinations/inspections
If you do consider getting a stereo microscope then I'd recommend something with prism lenses as this allows a more natural viewing angle. This does come at some expense of optical quality compared to the straight through stereo microscopes but it is worth it in my opinion. The quality of the prisms in the angled stereo microscopes is therefore very important and my Zeiss microscope is very impressive in this respect. I've not tried the Amcomm models but I've heard good reviews.
?
Also be aware that the straight microscopes often have a very restricted effective viewing area.? This can be like looking down a very narrow pipe and this can be tiresome and frustrating and also it's easy to get neck strain after a while as you have to look down the eyepieces all the time.
?
Also, just to clarify, the Mantis units at work are the Elite model and they have more than one magnifier fitted. This is another area where a stereo microscope can compete well. My Zeiss has a full (and very smooth) zoom control from low magnification to high magnification. It also has a wider viewing area than the Mantis.
?
To focus the Mantis you have to move the whole Mantis up and down by hand. This is absolutely fine for inspection work as you can hold the PCB in your hand and rotate it and find focus by moving the PCB with your hands.
?
Where the Mantis struggles in my opinion is when you want to do intricate soldering work on something that isn't flat. You have to set the item down on a bench and then fiddle with the height of the (very wobbly) Mantis in order to find focus. It's harder to control the focus, the work area is less and you have to re-find focus if you swap to a different magnifier. For all these reasons, a decent stereo microscope outclasses the Mantis in my opinion. That's why I recommend that you try before you buy. Don't just look down it and inspect something. Pretend to solder something and see if you are OK with the way it has to be moved up and down to focus itself. |
Re: microscope / high magnification camera options for soldering, faults, and other examinations/inspections
In the case of the Mantis, I would recommend to 'try before you buy' as the Mantis doesn't suit everyone. At work opinions are divided, some people avoid using the Mantis as they get distorted vision when using it. There is an adjustment control on the side of the instrument to counter this effect, but some people still can't use it. Other people really like it.
?
I think the Mantis is very bright and sharp and it offers a degree of 3D vision if you move your eyes slightly. It's at its best for SMD inspection work where it truly excels. I'm happy to use one but the view they give isn't as natural as something from a high quality stereo microscope.
?
A good stereo microscope can offer a wide view area and if a Barlow lens is fitted to it, the height above the work can be in the order of 120-150mm. This is a good height in my opinion.
?
Here at home I use an old Zeiss GSZ stereo microscope. It is a bit tired now and probably needs to have all the optics cleaned inside. However, I think it is much better than a Mantis when it comes to doing soldering work or any kind of intricate work. It has an external KL1500 cold light unit with it which gives very natural lighting.
?
The Mantis is best suited for inspection in my opinion with very sharp optics and very clinical lighting and a degree of 3D when you move your eyes. |