¿ªÔÆÌåÓý

Date
Re: 5086-7337 *Yig Oscillator issue*
Hi do you have the service manual with the CCT¡¯s ? If not you will find the A version in the files on this site including the CCT By the way you are working on an A version are all the parts you
By Paul Bicknell · #133278 ·
Re: 5086-7337 *Yig Oscillator issue*
When I was about 22 I rebuilt a 8620 Sweeper that arrived in kit form then found a 2 to 18 Ghz plug in Option HO so it went to 22 Ghz so this was more difficult to set up and took several days to get
By Paul Bicknell · #133277 ·
File /3D RP files/HP TYPE II FRONT FOOT.STEP uploaded #file-notice
The following files and folders have been uploaded to the Files area of the [email protected] group. * /3D RP files/HP TYPE II FRONT FOOT.STEP (
By Group Notification <noreply@...> · #133276 ·
Type II front foot
I created a CAD model of the Type II front foot and added it to the files section (added the '3D RP files' folder and placed it there). A rear foot model (minus the rubber insert) will follow soon.
By ChrisBeee · #133275 ·
Re: 5086-7337 *Yig Oscillator issue*
I made this plugin out ot two separated parts sets: one comprises everything but A1, A2, keyboard and front panel. The second set includes the boards and mechanical parts I needed to complete the
By RubenRubio · #133274 ·
Re: Agilent E3610A Operator Faux Pas or Production Change
Unfortunately this video is 11 years old so possibly too late but Dave at EEVblog had the unit you need and vice versa: https://www.youtube.com/watch?v=-04CQ0Mug1o His power supply had a Magtek
By freshndaire · #133273 ·
Re: 5086-7337 *Yig Oscillator issue*
Paul - In your opinion - Would the difference between boards be enough to cause no output? Cheers! Bruce Quoting Paul Bicknell <admin@...>:
By Bruce · #133272 ·
Re: 5086-7337 *Yig Oscillator issue*
Hi Ruben I thought I asked this question but apparently not on looking at the history , sorry if I am going over old ground You have made the unit out of 2 units and no output on the Aux socket on the
By Paul Bicknell · #133271 ·
Re: 5086-7337 *Yig Oscillator issue*
Sorry I haven¡¯t looked at the manual but the Aux output on the rear of the plugin should be the raw Yig output before it goes to the Multiplier / Yig filter As I often use this output to phase lock
By Paul Bicknell · #133270 ·
Re: 5086-7337 *Yig Oscillator issue*
Ruben - Confirmation should not be too difficult. Confirm: 1) The YIG main coil CURRENT is consistent with the frequency - somewhere in the service literature there will be a specification of ma/GHz
By Bruce · #133269 ·
Re: 5086-7337 *Yig Oscillator issue*
I got it I will measure again using the first harmonic band. Will post here the exact results. I am reluctant to think that the oscillator is dead, I hope that there is more ways to check it. The
By RubenRubio · #133268 ·
Re: Agilent E3610A Operator Faux Pas or Production Change
Hello, these can be made quite cheaply, and need some TLC before they can be used. I use the one described at https://www.youtube.com/watch?v=TSza2jD1DoM. Tam With best regards Tam HANNA Enjoy
By Tam Hanna · #133267 ·
Re: Agilent E3610A Operator Faux Pas or Production Change
Transport cost > value of item, likely. I have an E3611A, and I can confirm that mine is stuck to 115 V. I run it off a transformer. Of course I have a transformer (*). I can¡¯t quite imagine having
By Carsten Bormann · #133266 ·
Re: 5086-7337 *Yig Oscillator issue*
Hi Ruben I do know that the 10 meg to 20 Ghx is in 4 bands I was just checking you hadn¡¯t started looking at the fault wrongly If I am fault finding on the Multiplier plug ins I start at the
By Paul Bicknell · #133265 ·
Re: Agilent E3610A Operator Faux Pas or Production Change
7. Sell it off to 230V country
By Wilko Bulte · #133264 ·
Re: Agilent E3610A Operator Faux Pas or Production Change
Yes, finding or making an external transformer rig to make the 230V should be quite easy, especially considering that this is a pretty small (30W) supply. There's another option though, which is to
By Ed Breya · #133263 ·
Re: 5086-7337 *Yig Oscillator issue*
Actually from 2.3 to 7 gig, aprox. In the general block diagram, there is a detail of those figures per band.
By RubenRubio · #133262 ·
Re: 5086-7337 *Yig Oscillator issue*
Of course not My mistake, those voltage values are present during mainframe command sweeps, in this case, from 10 meg to 20 gig. YO supose to do four sweeps at different freq spans to cover all bands.
By RubenRubio · #133261 ·
Re: 5086-7337 *Yig Oscillator issue*
just for clarification are you saying one yig can sweep from 10 meg to 20 gig Sent: 12 March 2023 13:29 To: [email protected] Subject: Re: [HP-Agilent-Keysight-equipment]
By Paul Bicknell · #133260 ·
Re: 5086-7337 *Yig Oscillator issue*
Following the service manual: - Voltage across R1 is changing both in auto and manual sweeps, between 14 and 24 volts, from 10 meg to 20 gig, respectively. - Waveforms described in the figures are
By RubenRubio · #133259 ·