Re: My $25 "In Poor Shape" 3468A has arrived
Any of you guys ever tried one of those test lead sets that have interchangeable tips? I think they are/where US made and from the 70s or 80s. I remember my brand new 3476A DMM back in the 70s came
By Alex · #94780 ·
Dielectric measurements
I was asking about impedance measurements some time ago and mentioned Microwave Properties North, a local business. The link I gave was an old one because the site was down. It is now repaired and for
By peter bunge · #94779 ·
Re: 8753ES progress(?)
Peter, On my 8753D, you need to add "[Meas], ANALOG IN"? after the "MORE, REAL".? The "[numeric input], [x1]" then selects whatever analog input is desired. I think they just got the command
By John Gord · #94778 ·
Re: HP8562A firmware
Hi Yes, its 27C512 if you have the 6 eprom version. I think there is newer version of the cpu board that only have 4 eproms, so check. It is also advised to replace the eeprom, if its the original
By Askild · #94777 ·
Re: 11713A attenuator driver modification for 15V and 5V
I think I would modify the power supply section.
By Mark Bielman · #94776 ·
Re: 11713A attenuator driver modification for 15V and 5V
The "drive" to the attenuators is just open collector transistors switching to ground. the posiitve supply goes to the common This is pin 1 on the viking connector. To use on other voltages just
By Robert G8RPI · #94775 ·
Re: LCR meter advice
GR 1693 works from 12Hz to 200kHz. It is still being manufactured, BTW: https://www.ietlabs.com/1693.html I have two of those (one original GR and one later Quadtech unit with switchmode power supply)
By Sergey Kubushyn · #94774 ·
Re: My $25 "In Poor Shape" 3468A has arrived
On Thu, Feb 28, 2019 at 10:29 AM, ghnatiuk@... wrote: > > Dave, > A non-zero reading on low volts DC and AC range with an open input to the > meter means nothing other that you have pickup
By [email protected] · #94773 ·
Re: 11713A attenuator driver modification for 15V and 5V
Thanks for answer. Having a look at the real manual (the old one, not the one on the Keysight's web site without schematics) and at the drivers board, I find it is not easy as the 2V is not only used
By jfphp · #94771 ·
Re: My $25 "In Poor Shape" 3468A has arrived
Thanks George, I am not used to such quality equipment. ;-) Dave wrote: -- 72 de Dave VE7HR
By Dave Miller · #94770 ·
Re: TelNet Data logging Application
Hi Steve and Cary That looks sweet. I just got the software in another email. I will have to try it out soon. My HP3478 should arrive soon so I can try it out. Thanks Steve and Cary. Dave VE7HR wrote:
By Dave Miller · #94769 ·
Re: LCR meter advice
Sorry, ... kind of obvious: ?the GR 1693 is limited to 10 KHz measurements, ? ?assuming higher frequency HP / Agilent units trump this aspect.
By gren · #94767 ·
Re: LCR meter advice
Anyone know how the ?General Radio / IET ?1693 RCL ?Digibridge meter ?compared with the various HP/ Agilent ?LCR units ?? The 1693 RCL was supposed to have been a metrology lab instrument, for
By gren · #94766 ·
TelNet Data logging Application
I want to publicly thank Cary Oler for putting together a slick data logging and graphing application that I find highly useful and you may too. It runs under Windows 7 & Windows 10 (and probably
By Steve Hendrix · #94765 ·
Re: 11713A attenuator driver modification for 15V and 5V
Hello. Funny you should ask! I just purchased one of these (standard 11713A) for the purpose of testing HP/Agilent attenuators of various types and voltages. My plan is to somehow add external
By Mark Bielman · #94764 ·
Re: 8753ES progress(?)
I have the one without the integrated S parameter box, and yes I¡¯m feeding some of the output back to the R input. Definitely an internal problem. Peter
By Peter Gottlieb · #94763 ·
Re: 8753ES progress(?)
I assume this has the integrated s-parameter box? If not, put a power splitter on the source out and drive the R & A channels. That message occurs in these beasts when the R channel has no input. Jeff
By Jeff Kruth · #94762 ·
11713A attenuator driver modification for 15V and 5V
Hello, A lot of HP/Agilent/Keysight attenuators are operating under 15V or 5V instead of the traditional 24V supplied by the 11713A. Is there a HXX option for these supply levels or did anybody modify
By jfphp · #94761 ·
Re: HP 8648B and an off topic request.
Hi George, I hava a 8648B with the same symptoms, did you succeed in fixing it ? ? Thanks R¨¦mi
By Remi Castella · #94760 ·
HP8562A firmware
Hello, I'd like to upgrade the firmware of my HP8562A sa, Can any-one confirm I need to order 27C512 Eproms?? Many thanks, Harke
By Harke Smits · #94759 ·