The reply should probably be something like:
r 00,'hardcpy=(syslog,all,cmds)'
or
r 00,'hardcpy=(ddd,all,cmds)'
where "ddd" is a console that is a printer or printer-keyboard.
VS1 NIP's console interface is pretty basic, so you probably need to specify the "r 00,'" exactly, with leading zeroes and without excess spaces, and with the closing "'".
The code should be generated by assembling NIP, so it should be in the macro IEAANIP in SYS1.AMODGEN.
--
Kevin