Along the same lines....yesterday I installed a second
instance of fldigi onto my Windows 10 machine.? I now have
one instance (original) working with my TS590SG using Rig
CAT XML file and the second instance for my ICOM 9700 using
flRIG.? I only want to run one at a time. When I double
click on the new second instance, it does not launch right
away.? When I double click again, it launches but eventually
two versions show up, and one does not close on closing the
window.? I kill the task via Windows 10.
?
But, on the second instance, if I right click on the icon
(instead of a double click), and then select open, it
launches OK, runs OK, and closes OK.
?
Just some data for the heap, LOL.
?
Joe, K1YOW
?
--------------------
From: "Jack Spitznagel (KD4IZ)" <
kd4iz@...>
Reply-To: <
[email protected]>
To: <
[email protected]>
Sent: February 22, 2025 at 10:46 AM EST
Subject: [winfldigi] Potential Bug? fldigi instances not
closing out in Windows
Mostly addressed to Dave (W1HKJ) but also looking for
others experiences:
?
Scenario:
I am now running current alphas of fldigi and flrig
(autostarted) on a gamer Win11 workstation, but have seen
this issue? going back several "final" releases and on a
Win10 workstation. I use multiple instances of fldigi
talking to a single instance of flrig because flrig can do
KISS protocol and can control a single rig for multiple
instances of fldigi looking at that rigs sound CODEC stream.
?
Before the "frequent commentators" ask, I have had poor
luck setting up the other rig control engine because they
either did not work at all for my use case or were a mess to
configure. I have seen the problem with the other control
engines. I will be using flrig.
?
I can start a single instance of fldigi with flrig and
they will close out normally most always. The trouble does
start after long (days) running the apps.
?
When two or more instances are running with or without
flrig, I can almost always shut down the second instances,
but the primary instance will shut down (autostarted) flrig
but then hang and require one the "messy exit" routines to
kill the hung process. This problem happens very often as
quickly as 15 minutes or less after the programs are
started.
?
Quite a while ago I tried capturing the hang event
unsuccessfully - probably because the hang suspended the
debug logging writes?
?
@Dave: What is best way to log this event when it
happens?
?
@All: have you seen this same scenario when running
multiple instances of fldigi either with separate instances
of flrig (as in for two different radios) or a single
instance of flrig hosting multiple instances of fldigi?
?
Jack Spitznagel
KD4IZ - FM19OO
Parkton, MD