Keyboard Shortcuts
ctrl + shift + ? :
Show all keyboard shortcuts
ctrl + g :
Navigate to a group
ctrl + shift + f :
Find
ctrl + / :
Quick actions
esc to dismiss
Likes
- W4dccqa
- Messages
Search
I would like your opinion
genead1
Hi,
I currently have an 11' X 5' DC layout with one passing type siding which is non insulated with two Atlas remote turnout switches and and no yard so there are no electical blocks. This layout has one crossing track and several power feeds at various locations around the track. My question is: can I use, say, a starter DCC system by just unhooking the bus wires from my current DC powerpack and hooking the wires up to the DCC system (Booster I presume )? I would just like to control the speed of two or three trains on this one track. I also guess I would have to use a programming track to program the decoder in the loco's. By the way I do know that the loco's on this track would need to have decoders on board. Currently I am considering the Digitrax Zypher as the DCC system. Thanks for any info. Gene |
Boosters and tail lights
jchurc2004
Dear All
Having just retired I amm looking to get back into modelling. I have just acquired a Lenz 100 set with a LZV command station. Having read the web page Wiring for DCC I really like the idea of sub buses and tail lights to detect shorts apart from the fact that it conveniently divides the layout into blocks ready for computer control. What I need to know is the Lenz system suitable for the tail light system as suggested in the article or does it shut down so quickly that the bulb never lights!!! Thanks for your time ....John (UK) |
Re: Protecting Decoders
Ken
Wow! You packed a lot of info in that answer. So, the tests I did
before, where I set the O/P to 14Volts DC for a running engine and then stalled the motor and got a .91A current draw @about a 10 volt reading really isn't necessarally a .91 stall current? OOPS. Now I have to figure out how to keep the voltage up @14VDC. Never heard that before about the stall current being present @ startup, but it makes sense. I appreciate the explanations, Bob. They help. Ken --- In WiringForDCC@..., "bobgrosh" <bobgrosh@h...> wrote:
|
Re: Wiring Walthers/Shin 3-Way Switch for DCC
wirefordcc
Dave,
It is difficult to describe how to hook up the 3-way turnout in words. I'm going to make a drawing and add it to my website, but I may not have time to do so until my Christmas break. Here it is in a few words. I hope you can follow it. Use two of your favorite switchmachine to operate the two sets of points. Any switchmachine will do. Just be sure they each have at least 1 set of contacts for power routing frogs. Tortoises and the NJ International twin-coil type both have at least 2 sets of such contacts. Starting at the heel of the turnout, call the first set of points "A" and the second set "B". Then call the first frog you encounter "1", then "2" and then finally "3." Electrically tie frogs 1 and 2 together. Why they didn't do this has me wondering if I have made a mistake in telling you to tie them together. So I checked my work and it seems right. Frogs 1 and 2 are controlled by the power routing contacts of the switchmachine you use to control the A points. Frog 3 is controlled by the power routing contacts you use to control the B points. See one of the turnouts on my website for how to hook up power routing switches to your buses. Note that I have not specifically told you which bus the power routing contacts are to be hooked to. That's because unless you are extremely careful, you will hook them up wrong. So why fight Murphy? Just hook them up one way and try running a loco across the turnout. If it shorts, swap the wires going to the power routing contacts and try again. I'll post on this forum when I get time to make a drawing and add it to my website. Allan |
Re: Protecting Decoders
Hi Ken!
You asked: QUESTION: Is there some other way, that I'm not seeing and shouldbe much worried about, to short out the decoder and that is whatIf the decoder is properly wired, not under rated for the load, and does not take a dip in the "very realistic lake", chances are that only a motor failure could take out a decoder. My perspective is from garden scale where 3, 5 and 8 amp decoders are the norm. (so are real lakes) So, this may not apply to you if you are in one of the small scales. What we have learned from garden railroads may be important in small scales too. Burning out decoders: 1 - Stall current: Most people measure the stall current wrong. You have to monitor the input voltage and the current with the motor locked. For example if the supply only puts out 5 amps at 18 volts and you measure 4 amps but don't look at the voltage, (which may have dropped to 9 volts) you could wrongly believe that the stall current is only 4 amps, when in fact it may draw 10 or 11 amps at the full 18 volts. All to often I've seen people measure the maximum output current of their power packs when they thought they were measuring stall current. Most decoders can not handle more than their rated stall current for more than a second. DO NOT ASSUME THAT IF YOU NEVER STALL YOUR LOCO OR THE WHEELS WILL SLIP FIRST, THAT WILL SAVE YOU. When you first give a motor it's first kick from a decoder, the motor is stooped. IE! IT IS STALLED!!! A motor will always draw it's stall current for some period of time before it starts moving. The point is, Always make sure the stall current (or peak current) rating is grater than the stall current of the motor. If the loco manufacture does not tell you the stall current of the motor, measure it while monitoring and maintaining full voltage. It seems likely to me (because I have seen this happen more than once,) an under sized decoder straining to get cars moving will fail when there is a derailment somewhere in the train . The operator/owner blames the failure on a short because of the derailment. He defends his conclusion because he saw lights on the layout flicker. In reality, the decoder was blown because the derailment stalled his loco and the lights flickered when vital parts of the decoder melted. Burning out decoders: 2 - Failed motors: Poor quality motors can fail. They can short out. In this case a fuse between the motor and the decoder (not between the decoder and track) might protect the decoder. However, if a failed motor shorts out it's windings, it will draw much more current than the stall current. If that happens for more than a few milliseconds the H-bridge will be fried. Most fuses will not open the circuit fast enough to provide any meaningful protection for the motor output of the decoder. In garden railroads, experienced railroaders opt for decoders with built in over current, short circuit and thermal overload protection. ( Such decoders will simply flash all the lights if mis-wired and placed on a track.) All that fancy circuitry probably does not fit in HO or N. ( But then you guys don't put tachometer monitored brush- less DC cooling fans on your decoders either.) :>) In Garden scale popular locos like the SD45 have four motors, each drawing more current than your whole train. If a motor fails it is usually replaced. Even if is decided not to repair the loco, we usually remove the decoder for use in some other loco, We have almost no custom decoders designed for a single loco, one or two sizes fit all. If a small scale loco burns out the motor and it can't be repaired, then the decoder possibly will not fit in some other loco it was designed for. Because of this, and considering the cost of a decoder, it may not we smart to put try to put expensive protection circuitry in small scale locos. If you want to protect the decoders from motor failures, then there is only one way I know of to do this. Limit the available current to the decoder to the maximum amount of current they can safely supply. That is what power managers like the PM42 are designed for, and why some people use power districts with multiple smaller boosters rather than one giant booster. For example on my "G" scal layout, I could use 3 amp decoders in some locos, but I don't. I use 5 amp decoders, that can dandle 10 amps peak. My boosters are all 8 amps each, so if a motor shorted out, the decoder only has to handle 8 amps, even tho it is designed to handle 10. As a result, the booster for that train will always cut off before the decoder is damaged. Don't know if this helps answer your question, but it's the best I can come up with. B0B |
Re: Protecting Decoders
Ken
Exactly, Bob! While I'm really, really new (as in weeks) to DCC and
not an electrical guru at all, I have read and heard so much about the crying fear of decoders being blown because there is a short. I agree that if there's a derailment and the wheels short (like your crowbar example)that's a power supply concern and not a decoder problem. Ignoring the "obvious" wiring errors, the only way I can see a decoder being blown because of a short is if: 1)the decoder output is connected directly to the rails, which is possible if the motor is not, or rather no longer, isolated 2) or if the wires, or some component on the PCB, ground outs on the metal chassis, 3) or the wires somehow become cross connected because their solder connection breaks and the wire moves or their insulation is worn away 4) the decoder self destructs internally because of heat or excess current draw or component aging Seems to me most of these are preventable in the first place by studying the loco, the decoder and its needs, existing wiring if any and the careful placement, wire routing, connecting and soldering of the decoder and its connecting wires, including the speaker and its leads. QUESTION: Is there some other way, that I'm not seeing and should be much worried about, to short out the decoder and that is what generates all this talk and fears? Thanks in advance. Ken --- In WiringForDCC@..., "bobgrosh" <bobgrosh@h...> wrote: power--- rotortips <Rotortips@s...> wrote:No supply. |
Re: Protecting Decoders
--- rotortips <Rotortips@s...> wrote:No First!!! A fuse does not protect the item being powered. It protects the power supply. If your decoder shorts out, burns up or melts and draws the maximum amout of current your supply can provide, the circuit breaker ( or electronic equivilant inside the booster) will disconnect power from the rails to prevent damage TO THE BOOSTER. It can not prevent damage to the decoder, because the decoder is already damaged. Adding a fuse to the engine simply duplicates the fuse that is already in the booster. Second!!! There is nothing that can "protect" a loco from a short circuit! Nor is there any need to protect a loco from a short circuit. If you have a shots circuit on your layout (IE laying a crowbar across the rails) then the voltage on the track is "shorted out". That is to say that there is no voltage (or almost no voltag) across the rails. A short can no more do damage to the loco than turning off the power or lifting the loco from the track. In fact, better power supplies include a "crowbar" circuit. This is a circuit that monitors the output of the power supply, and, if the supply malfunctions and starts to put out TO MUCH VOLTAGE, the circuit shorts out the supply output in order to blow the supplies fuse. B0B |
Re: Protecting Decoders
Vollrath, Don
Fuses react much too slowly to offer protection to the dainty components inside a decoder.
toggle quoted message
Show quoted text
DonV -----Original Message-----
From: WiringForDCC@... [mailto:WiringForDCC@...]On Behalf Of rotortips Sent: Friday, October 21, 2005 5:15 PM To: WiringForDCC@... Subject: [WiringForDCC] Protecting Decoders Has anyone tried to use a thermal circuit breaker or 1 Amp fuse between an engine pick-up wire and the decoder to protect the decoder from short circuits? Rotortips |
Re: Protecting Decoders
mike thurston
don't think they will fit in scales lower than O
zekda99 --- rotortips <Rotortips@...> wrote: --------------------------------- Has anyone tried to use a thermal circuit breaker or 1 Amp fuse between an engine pick-up wire and the decoder to protect the decoder from short circuits? Rotortips SPONSORED LINKS Lionel model train European model trains Model railroads Ho scale model train Ho model trains Model train n scale --------------------------------- YAHOO! GROUPS LINKS Visit your group "WiringForDCC" on the web. To unsubscribe from this group, send an email to: WiringForDCC-unsubscribe@... Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service. --------------------------------- __________________________________________________________ Find your next car at |
Re: Wiring Walthers/Shin 3-Way Switch for DCC
Dave
Thanks for the reply, Allan. I appreciate your time and expertise!
The switch itself is properly wired, and I even added the jumper wires for the point rails like you suggested. And I understand which polarity needs to power the frogs per postion of the two sets of points. The real question I have is control. How do I control the 3 seperate frogs to provide the correct polarity for the 4 possible track positions? I saw the section on setting up a micro switch/piano wire for a single frog. Is there a particular switch machine or circuit board I could build to deal with the various "if" scenarios associated with a 3-way turnout?? Thanks again! DAVE --- In WiringForDCC@..., "wirefordcc" <wire4dcc_admin@c...> wrote: words. I'll try to see one at my local hobby shop the next time I go andI'll make a drawing. Don't hold your breath waiting for the drawing.I'm working full time and going to school at night. My weekends aretaken up studying. The drawing won't likely appear in my web page untilthe end of the semester.Make 3 drawings; one each for the 3 routes the train can take. Labelthe stock rails + and - and follow it through the turnout. By notingyou will know which frog needs to be controlled by which set of points. |
Many Many Questions.
up3900
Hello Everybody.
I am in the middle of planning a new layout. My layout has been DCC controlled using an older Digitrax Empire Builder system. However now that I am expanding I have many many questions and the answers I find are written in engineering eze and I do not fully understand what they are saying. Before I flood everyone with a bunch of questions should I make each question a separate post or should put them all in one long e-mail. I have looked through Allens site and answered all the track rolling stock how to solder it up questions. The ones that are left deal with the hardwar and features and the potential of what it can do or how can I make it do what I want it to. I like how digitrax is set up and think I want to keep using it. Given the space I have to fill and the and the gerneral lack of population where I live I have to run my layout pretty much by myself. So I need some way to dispatch all of this but I do not want to hook up a computer because that will detract from the 1969 feel I am trying to convey. Thanks and once I am informed as to how I should post my questions I will post away. James |
Re: So no plastic rail joiners needed when using DDC to run locos ?
--- In WiringForDCC@..., "Marcus Ammann" <mammann@o...>
wrote: the relevant plastic rail joiners where there is a possibility of ashort, just like any layout.to isolate locos because the DCC decoder has a unique address andwill only respond when addressed, leaving all other DCC locos on the track,to large layouts for troubleshooting etc. A small single operator layoutwill operate satisfactory with only one power district.[mailto:WiringForDCC@...] On Behalf Of jeffln55using DDC to run locos ?Locos.
Thanks okay understood. Lucky I asked first. |
Re: So no plastic rail joiners needed when using DDC to run locos ?
Hi jeffln55
toggle quoted message
Show quoted text
You have to wire up a DCC layout the same as a DC layout, with all the relevant plastic rail joiners where there is a possibility of a short, just like any layout. You don't have to wire in any "blocks" that are used in DC layouts to isolate locos because the DCC decoder has a unique address and will only respond when addressed, leaving all other DCC locos on the track, stationary. Power districts, a form of blocks, is recommended for most medium to large layouts for troubleshooting etc. A small single operator layout will operate satisfactory with only one power district. Visit Allan Gartner's Wiring for DCC at for answers to all your questions. Marcus. -----Original Message-----
From: WiringForDCC@... [mailto:WiringForDCC@...] On Behalf Of jeffln55 Sent: Monday, 17 October 2005 10:52 PM To: WiringForDCC@... Subject: [WiringForDCC] So no plastic rail joiners needed when using DDC to run locos ? Hi well are no plastic rail joiners needed to run DDC powered Locos. So no blocks correct? Now all that is needed is the decoder added and run correct. Thanks this will be a new layout so wiring is not started as of yet. Yahoo! Groups Links |
Re: Overheating
Hi asterrymc
toggle quoted message
Show quoted text
12 volt lamps are ok for loco headlights when operated on DC due the headlight only illuminates dimly when going slow and bright when going faster. This also applies with constant brightness circuits and the lamp is brighter with slow operation. When the loco stops the light is extinguished. In DCC the headlight is illuminated bright when it is selected on and stays illuminated with the loco stationary. Only off when selected off. This can mean the headlight can be illuminated all the time while the power is supplied to the layout. Light is on all the time. A 40 mA incandescent dissipates about 1/2 a watt and this over a long time will certainly cause some heat. This is one of the reasons that I change all my incandescent lamps to Prototype White LEDs. Incandescent lamps make lots of heat and a little light, while a LED makes a lot of light and a little heat. Secondly a LED generally only needs about 10 - 15 mAs of current. I suggest for you next installation you use LEDs for the headlights. Make sure you use Prototype White, Golden Glow or similar ones that don't have the blue tinge that normal white LEDs have. The white LEDs are ok for late model diesels, but not early and steam engines. Marcus -----Original Message-----
From: WiringForDCC@... [mailto:WiringForDCC@...] On Behalf Of asterrymc Sent: Sunday, 16 October 2005 10:07 PM To: WiringForDCC@... Subject: [WiringForDCC] Overheating My first attempt at installing a DCC decoder in an old style Life-Like GP18 (N scale) took much longer than I thought and with perseverance I succeeded. The loco ran smoothly and the decoder functions all worked. I even added a light for reversing. After running it for a while I noticed that the grain of wheat bulbs I had installed where starting to melt the case badly. I used 12V bulbs - how do I overcome this heat problem for the next install? Yahoo! Groups Links |
Re: Wiring Walthers/Shin 3-Way Switch for DCC
wirefordcc
Dave,
I'd like to answer your question, but I haven't seen one of these turnouts yet. Even if I had, it would be hard to describe in words. I'll try to see one at my local hobby shop the next time I go and I'll make a drawing. Don't hold your breath waiting for the drawing. I'm working full time and going to school at night. My weekends are taken up studying. The drawing won't likely appear in my web page until the end of the semester. In the interim, I suggest the following: Draw out the turnout. Make 3 drawings; one each for the 3 routes the train can take. Label the stock rails + and - and follow it through the turnout. By noting which set of points was moved to change the polarity of the rails, you will know which frog needs to be controlled by which set of points. Allan |
Overheating
asterrymc
My first attempt at installing a DCC decoder in an old style Life-Like
GP18 (N scale) took much longer than I thought and with perseverance I succeeded. The loco ran smoothly and the decoder functions all worked. I even added a light for reversing. After running it for a while I noticed that the grain of wheat bulbs I had installed where starting to melt the case badly. I used 12V bulbs - how do I overcome this heat problem for the next install? |
Re: do I need new bus wires
Brian, as my branch line is really a preserved line with a main line
connection, engines crossing from main to branch will not be an every day occurrence,so Iam prepared to put up with the two throttle option for now. But one more problem has just come to light, I cant find my Compact!! I thought it was in its box, but its empty! and I`ve spent the last hour looking for it. I will have to re-think this idea through, the only reason I started this was to try and avoid a short stopping the whole layout with out spending money on more equipment. You have been very helpfull and I`ve learnt some thing in the proccess. I dont suppose you live in Wiltshire? David. |
to navigate to use esc to dismiss