Tom, there is a difference between a ¡°short ¡° or short circuit that causes a circuit breaker to trip and a loco to stop, and an ¡°open¡± that simply causes a loco to stop. Be
sure to use the proper words. ?In your case It sounds like you have an open connection or broken wire, etc. use a voltmeter to help find where and why you loose DCC track voltage. Shorts can be caused by miswiring of the left and right rails as a loco crosses
an isolated boundary between sections. Look for voltage across the same rail isolating gaps. It should be minimal. If there is significant voltage there you have a voltage Mis-match in your wiring.?
NCE DCC EB1 Circuit Breakers?
From:?trgrassijr@...
Date: Fri, 26 Mar 2021 09:57:44 CDT?
Hello All?
New to this Group?
Hope all are safe and well.
I have a small layout and runs 3 trains at the same time.? Have 14 switches
Use Atlas code 83 track on my layout.
I use NCE Power Cab to control my trains.
sometimes a train would derail at a switch and that would short circuit my entire layout.?
So I decided to setup Districts on my layout I have three districts now and forth one in planned.
My layout was all tied together by switches as cross overs.? also have a double cross over on district 2 and 3??
So I had to isolate the track on district 1 from district 2 and 3? ?in doing that I ran into a few minor issues.? On District 1 I found I now had a dead section of track which worked fine before I isolated the track.
After many trouble shooting step I found I had a bad feeder wire on a piece of track before the dead section.? I think it was shorting in out somehow.? Replacing the wires will be done soon currently I disconnected them from my buss.
My buss is a 14 AWG stranded pair of speaker wire??
Now with the three districts I have three separate buss lines?
My problem now is on District 2 on a section of the track it short circuits and the train stops?
I have feeders before the section and after the section it is a dead spot not sure what to check
I tried to put my layout here but it would not let me.
Re: NCE DCC EB1 Circuit Breakers?
From:?wirefordcc
Date: Fri, 26 Mar 2021 10:50:13 CDT?
Hi Tom,
Can you upload a drawing of your layout to this groups files section?? Show where your problems are. I or someone else should then be able to help you.
DB210 with DCC++ EX Command Station?
From:?Blair
Date: Fri, 26 Mar 2021 14:40:36 CDT?
A friend recently purchased a Digitrax DB210 as someone told him he'd need one for his layout.
He's trying to figure out how to connect it to his DCC++EX base station.
Can he simply use the signals from his rails to feed the Loconet RailSync wires to the booster (he wouldn't need more than 5A, so the DCC++ rail outputs are otherwise unused)?? What about the 'ground' reference booster input?? I suspect that's not necessary
as long as he's running just the one booster for the whole layout - unless he uses a PM42, obviously, or other Digitrax device that needs the reference.? Comments?
Blair