Re: Cables for GE Mastr II S3V225UAUHA
WARNING!!!!
This is a classic attempt of a Junkenders infected person trying to draw you into their ranks.? Your parents warned you about such people.
Joe
By
Joe
·
#169303
·
|
Re: Cables for GE Mastr II S3V225UAUHA
Speaking of the Devil.... (GE Mastr ii High Power, Paralleled Amplifiers)
Not having read the first portion of the thread, I don't know if this has already
been brought up... but,
The exact
By
skipp025@...
·
#169302
·
|
Re: Cables for GE Mastr II S3V225UAUHA
I try not to think too much... but the answer to your question
is just the location in the cabinet.
s.
By
skipp025@...
·
#169301
·
|
Re: Final notice
What are you disagreeing with??
You have no reference to anything.
Glenn
--
-----------------------------------------------------------------------
Glenn Little ARRL Technical
By
Glenn Little
·
#169300
·
|
Re: TKR-850-1 v.1 repeater parts needed
Anyone with TKR 850-1 v.1 Parts please contact me I am in need of?a complete rx board or another TKR no one needs cheap I can usefor a temporary back up.
By
Ron Sales <rre49sale@...>
·
#169299
·
|
Re: Final notice
well, I will just have to disagree with all that!
Repeaters anyone?
By
RFI-EMI-GUY
·
#169298
·
|
Re: Cables for GE Mastr II S3V225UAUHA
skipp,
Do you think the specific cable lengths were done for circuit design, or just convenience of cabinet equipment installation?
Joe
By
Joe
·
#169297
·
|
Re: Kenwood TKR-750 Ver2 AUX I/O Programming Help for COR - CTCSS TX Triggering?
If you're using the internal controller. program
up Aux In/Out 4 for QT/DT Enc Enable. Program up
Aux In/Out 6 as an output and for COR as Active
Low. Jumper pins 23 and 25 of the DB25 on the rear
By
Ken Arck AH6LE
·
#169296
·
|
Re: Kenwood TKR-750 Ver2 AUX I/O Programming Help for COR - CTCSS TX Triggering?
I'm trying to get the Repeater to send QT tone only on a COR signal.
Then my remote link station will be set to have RX Tone, so the repeater CW ID won't go through the Internet link.
Scott
By
VA3EXT
·
#169295
·
|
Re: Cables for GE Mastr II S3V225UAUHA
A few years past, directly behind the Dayton Hamvention, Hara
Area Repeater Builder / Jeff / Junk Enders Group, Flea Market
location (mouth-full wasn't that) ... one of the surplus everything
By
skipp025@...
·
#169294
·
|
TKR-850-1
https://groups.yahoo.com/neo/groups/Repeater-Builder/photos/photostream/lightbox/913375281?orderBy=mtime&sortOrder=desc&photoFilter=ALL#
By
rre49sale@...
·
#169293
·
|
OT---Re: Re: Final notice
I wish everyone would stop blaming the insurance companies and medical professionals for all of this. As a business, they are only reacting to consumer demands and (mostly) government regulations. The
By
Jim Barbour
·
#169292
·
|
Re: Cables for GE Mastr II S3V225UAUHA
That's what I was talking about. While the RF devices are only conducting
during a portion of the AC waveform cycle, the collector/drain choke and all
of the other filtering (capacitors, inductors)
By
Jeff DePolo WN3A
·
#169291
·
|
Re: Cables for GE Mastr II S3V225UAUHA
What about a class C amplifier used in FM?
Joe
By
Joe
·
#169290
·
|
Re: Link antenna polarization
That's a great question Larry,
There is a case for polarization selection. Some of our sites here in the
Southwest can have 3, 4, 5 or more duplex UHF links at once. All expected
to operate free of
By
Matt Lechliter
·
#169289
·
|
Re: Final notice
I hope this is my last post on this subject ... on my last hip replacement
surgery (I've had 'em both done) my surgeon actually DID NOT KNOW what the
hospital billed me.
So I gave him a copy of the
By
Jim Strohm
·
#169288
·
|
Re: Cables for GE Mastr II S3V225UAUHA
Thanks for the update, it all makes sense.
Being a 'typical' amateur I'd have been looking at doing the split and combine in the absence of a professional device.
By
Ray Sohst
·
#169287
·
|
Re: Cables for GE Mastr II S3V225UAUHA
Ray - if you've never worked on a high-power solid-state VHF or UHF Master
II, they come with high-power Wilkinson splitter and combiner external to
the PA's. Inside those units are quarter-wave
By
Jeff DePolo WN3A
·
#169286
·
|
Re: Cables for GE Mastr II S3V225UAUHA
How do you figure?
Amplifiers consume DC power. They don't consume RF. The DC current being
pulled by an amplifier operating an emission that lacks any amplitude
variation (such as FM) will pull
By
Jeff DePolo WN3A
·
#169285
·
|
Re: Cables for GE Mastr II S3V225UAUHA
The only time I've used amplifiers in parallel they had measured sections of 75ohm [could have been 1/4 waves] to split into and combine out of the PAs.
Just paralleling will present 25ohms to six
By
Ray Sohst
·
#169284
·
|