#flrig Switching from CW to FT8 leaves filter width at 500 Hz #flrig


 

This is a problem that has been bugging me for sometime. I finally decided to look into it.

I am running an IC-7300 and connecting to it with flrig. Most times I change my operating from CW to FT8 the filter bandwidth remains at 500 Hz. I am using WSJT-X to effect the switch. I have found the trace where WSJT-X is requesting the mode change and can see the XML and CAT interfaces. In the section below I see 4 CI-V transactions:

at 681 ms - On selected VFO, set USB-D, filter 1.

at 684 ms - Set bandwidth 9 - which I assume is what is setting it to 500 Hz (0 is 50 Hz, 40 is 3600 Hz).

at 686 and 689 ms - these are setting default Twin PBT settings.

Should we keep the bandwidth when we change modes or just keep the selected filter or even select the default filter for that mode?

73 Phil GM3ZZA



14:52:21.680 : readRequest:
?<?xml version="1.0"?>
<?clientid="hamlib(24283)"?>
<methodCall><methodName>rig.set_modeA</methodName>
<params><param><value>USB-D</value></param></params></methodCall>
14:52:21.681 : WriteBuffer:? FE FE 94 E0 26 00 01 01 01 FD
14:52:21.683 : 1: ReadEcho [2.13 msec] (10): FE FE 94 E0 26 00 01 01 01 FD
14:52:21.684 : ReadBuffer [3.254000 msec]: FE FE E0 94 FB FD
14:52:21.684 : WriteBuffer:? FE FE 94 E0 1A 03 09 FD
14:52:21.686 : 1: ReadEcho [2.13 msec] (14): FE FE 94 E0 1A 03 09 FD FE FE E0 94 FB FD
14:52:21.686 : ReadBuffer [2.175000 msec]: FE FE E0 94 FB FD
14:52:21.686 : WriteBuffer:? FE FE 94 E0 14 07 01 28 FD
14:52:21.688 : 1: ReadEcho [2.12 msec] (9): FE FE 94 E0 14 07 01 28 FD
14:52:21.689 : ReadBuffer [3.224000 msec]: FE FE E0 94 FB FD
14:52:21.689 : WriteBuffer:? FE FE 94 E0 14 08 01 28 FD
14:52:21.692 : 1: ReadEcho [2.12 msec] (15): FE FE 94 E0 14 08 01 28 FD FE FE E0 94 FB FD
14:52:21.692 : ReadBuffer [2.161000 msec]: FE FE E0 94 FB FD
14:52:21.692 : writeResponse:
?HTTP/1.1 200 OK
Server: XMLRPC++ 0.8
Content-Type: text/xml
Content-length: 120

<?xml version="1.0"?>
<methodResponse><params><param>
??? <value><i4>1</i4></value>
</param></params></methodResponse>