开云体育

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Re: Footprint without schematic symbol
Place all units does work, but you have to be a little careful to avoid "clickitis" :-) in the circuit editor add symbol select switch / SW_DP3T (here you can select either the entire unit, or each
By Andy · #24028 ·
Re: Disaster recovery?
Sorry to hear about the problem. Does ctrl-Z work to undo things? (been a while since I actively used kicad. With all due respect, shame on Kicad for the lame behavior and poor excuse. IMHO,
By John Hudak · #24027 ·
Re: Disaster recovery?
Thanks, Robert, but I've already started again. -- This email has been checked for viruses by AVG antivirus software. www.avg.com
By John Woodgate · #24026 ·
Re: Disaster recovery?
No, Tony, I wouldn't dream of it. But I just forgot to save the schematic before going to bed at 0030. -- This email has been checked for viruses by AVG antivirus software. www.avg.com
By John Woodgate · #24025 ·
Re: Disaster recovery?
In the "Update PCB from schematic" tool in version 7, IIRC you just have to *not* select "Re-link footprints to schematic symbols based on their reference designators". If that doesn't work, you can
By Robert · #24024 ·
Re: Disaster recovery?
You don't want to get me started about <users> making backups of anything valuable, do you?? ;-)? I think we've had that conversation before. -- Regards, Tony
By Tony Casey · #24023 ·
Re: Disaster recovery?
Unfortunately, the backup I need is corrupted (KiCad apology message received) , due to having KiCad running while some other updates were going on. It looks like I have to start all over again. --
By John Woodgate · #24022 ·
Re: Disaster recovery?
In KiCad 7 and 8, they are at C:\Users\[user]\AppData\Roaming\kicad\X.0\user.hotkeys, but the texts are barely readable by humans. -- This email has been checked for viruses by AVG antivirus
By John Woodgate · #24021 ·
Re: Disaster recovery?
Thanks, Tony. I will investigate. It would be good to put those locations in the Manual.
By John Woodgate · #24020 ·
Re: Disaster recovery?
It's 'Update the PCB from schematic' that causes the problem.? V8 seems quite a bit different from v6, and better, but driving lessons are required.
By John Woodgate · #24019 ·
Re: Footprint without schematic symbol
Yes, it does work, but 'Place all units' doesn't work. I had to find a work-around to get both poles into the schematic.
By John Woodgate · #24018 ·
Re: Disaster recovery?
As an aside to the problem you have, it may be worth investing in a copy of this two volume 'book' https://techexplorations.com/so/kicad-like-a-pro-4th-edition/ Comes in PDF, epub, and Kindle
By Alan Pearce · #24017 ·
Re: Disaster recovery?
Fortunately, KiCad saves backups. Look in your PCB project directory. You should have a folder of zips called "<Project_name>-backups". For the hotkeys, find where the KiCad configuration files are
By Tony Casey · #24016 ·
Re: Disaster recovery?
You should be able to 'feed forward' the changes. That should then renumber the component placements. I can't remember the appropriate commands at the moment, and I also haven't got around to playing
By Alan Pearce · #24015 ·
Disaster recovery?
I asked KiCad to renumber the components on the schematic. What I didn't realise is that it turns the PCB into a disaster area, because many of the components are then in the wrong places, with wrong
By John Woodgate · #24014 ·
Re: Footprint without schematic symbol
Thanks, Andy. Yes, that's what I should be doing, but it's a big job to get started on. I'm trying to appease the alligators, before draining he swamp.
By John Woodgate · #24013 ·
Re: Footprint without schematic symbol
SW_DP3T looks something like what you are asking form it's in the switch lib. Get used to making your own footprints and symbols it's one of the most useful things you can do as it's a great time
By Andy · #24012 ·
Footprint without schematic symbol
I want to use a double-pole switch with centre-off position, and the footprint: Button_Switch_THT:SW_Push_2P2T_Vertical_E-Switch_800UDP8P1A1M6 is good. But I can't find? a schematic symbol for it,
By John Woodgate · #24011 ·
Re: Problemsending data from schematic to PCB
Yes, that was the problem, but the designations need to show in order to put the components in their places.
By John Woodgate · #24010 ·
Re: Problemsending data from schematic to PCB
I agree that this just sounds like the layers are switched off usually on the right hand side of the window there is a panel with some tabs Layers Objects Nets Select layers and make sure there is
By Andy · #24009 ·