Re: Route track with error ?


 

To me it looks like pins 3 and 4 of SW1 are not connected to anything in
the schematic, and therefore shouldn't be connected to anything on the
PCB. If SW1 is one of those where 1 and 4 are connected internally,
and 2 and 3 are connected internally, you still have to have all four
pins on the schematic. A convenient way to do this would be to create
a switch symbol with pin 4 overlaid on pin 1, and pin 3 overlaid on pin
2. That way your switch only appears to have two pins on the
schematic, but on the PCB it has all four, with the internal connections
automagically present (you still have to connect the internally
connected pins with tracks, as you appear to be attempting to do).

Regards,

Robert