Locked
Re: Problem migrating Panelpro from Windows XP with MS100 to a laptop with PR3 connection
John, As others have pointed out, you failed to satisfactorily achieve the first step of my instructions: "- Set up a single connection to the PR3 with the same Connection Prefix as your old MS100
By
Dave Heap
·
#165192
·
|
Locked
Re: Problem migrating Panelpro from Windows XP with MS100 to a laptop with PR3 connection
John, The log you provided is NOT actually connecting to a LocoNet connection. If it was, you would see specific information about serial connection settings in the log file. But they are not present,
By
billybob experimenter
·
#165191
·
|
Locked
Re: Car Weights
#operationspro
Thanks Dan, That's exactly what I wanted to know. 1) I assume that when entering weight for a car you would enter the fully loaded weight? 2) I usually enter the car's n-scale weight, so a 50ft boxcar
By
larrylandes@...
·
#165190
·
|
Locked
Re: Car Weights
#operationspro
Larry, A train's manifest shows the weight of the entire train.? The program provides an estimated loaded weight based on car length.? You can override this and enter your own loaded weight for any
By
Dan Boudreau
·
#165189
·
|
Locked
Re: Problem migrating Panelpro from Windows XP with MS100 to a laptop with PR3 connection
I used to have that problem until I tried?Finding & Removing Hidden COM Ports ¨C rttycontesting.com? | | | | | | | | | | | Finding & Removing Hidden COM Ports ¨C rttycontesting.com | | |
By
davethomas1359@...
·
#165188
·
|
Locked
Re: Moving from NCE system to DRS5000
What stationary decoders are controling the turnouts ??? via bus or via rails ? The decoders must now talk to the DSR5000. Marc
By
forfoum@...
·
#165187
·
|
Locked
Anyone running JMRI in a Windows emulator on an Android tablet
Hi everyone, Just wondering if anyone is doing this.? Thoughts on requirements for the Android tablet and/or Windows emulator package would be appreciated. Thanks in advance, Chris from Canada
By
Chris Mawdsley
·
#165186
·
|
Locked
Re: Problem migrating Panelpro from Windows XP with MS100 to a laptop with PR3 connection
John, I recommend that you solve one problem at a time. 1. Stop JMRI if it is running. 2. Rename C:\Users\Lucas\JMRI to C:\Users\Lucus\JMRI-original or whatever makes sense to you. 3. Start PanelPro.
By
Dave Sand
·
#165185
·
|
Locked
Re: Problem migrating Panelpro from Windows XP with MS100 to a laptop with PR3 connection
John, Not that I am an expert but it would appear by the internal that your profile settings are not correct. It is set to internal not a DCC system. Also while COM3 may have been used before, best
By
David Klemm
·
#165184
·
|
Locked
Re: Problem migrating Panelpro from Windows XP with MS100 to a laptop with PR3 connection
(e) OK, it seems I had two panels -- one now deleted. But still no joy. Here is part of the log file: 2019-10-28 17:35:08,614 apps.Apps???????????????????????????? INFO? -
By
John Cornell
·
#165183
·
|
Locked
Re: Problem migrating Panelpro from Windows XP with MS100 to a laptop with PR3 connection
Hi Dave -- thanks for your input. (a) Yes, the connection is probably L, (b) Yes I have installed a completely new JMRI 4.12 (c) There were no "startup" files listed on the XP (d) To start JMRI, I
By
John Cornell
·
#165182
·
|
Locked
Car Weights
#operationspro
Regarding car weights in OperationsPro.? I have seen comment regarding calculated car weights on empty verses full cars, but have not seen any evidence of it.? Does Operationspro take into account
By
larrylandes@...
·
#165181
·
|
Locked
Re: Decoder Pro and Indexed CVs
Charley, You don't need to know how to program indexed CVs when using DecoderPro. There are a number of different ways (depending on manufacturer) and DecoderPro is set up to automatically do this
By
Dave Heap
·
#165180
·
|
Locked
Re: Moving from NCE system to DRS5000
I found an old message where someone suggested creating the new turnout with same name in new system and moving but this does not appear to work.? When I go to the new connection the listing of
By
Doug Johnson
·
#165179
·
|
Locked
Re: Problem migrating Panelpro from Windows XP with MS100 to a laptop with PR3 connection
John, I'm suggesting a fresh start and approach to this. Fine. You need to note three main things on the XP machine: - The Connection Prefix of your MS100 connection (it's most likely "L"). - Find and
By
Dave Heap
·
#165178
·
|
Locked
Moving from NCE system to DRS5000
Hi all, As the above title suggests I am trying to move from my old NCE power cab to a Newer Digikeijs DRS5000 system.? I have it up and running and have even worked out how to connect JMRi to it via
By
Doug Johnson
·
#165177
·
|
Locked
Decoder Pro and Indexed CVs
Is there a File on how to used Decoder Pro3 with Indexed CVs, or a Message for doing so?? I've been looking but haven't found it. Charley Goddard
By
Charley Goddard <cgalfa@...>
·
#165176
·
|
Locked
Re: Problem migrating Panelpro from Windows XP with MS100 to a laptop with PR3 connection
OK, I added only the My_Road.jmri folder (with its contents) to the User/username/JMRI folder. Same result as before with the LT1 message. The red led on the PR3 flashes to show attempted connection
By
John Cornell
·
#165175
·
|
Locked
Re: Problem migrating Panelpro from Windows XP with MS100 to a laptop with PR3 connection
OK, 4.12 now installed. Do I need the WHOLE User/Username/My_JMRI_Railroad folder from the PC, or just put the My_Railroad.jmri file inside the emptyfolder? (I don't understand why you said the folder
By
John Cornell
·
#165174
·
|
Locked
Re: Problem migrating Panelpro from Windows XP with MS100 to a laptop with PR3 connection
John, "LT1 needed IT followed by a suffix". Any idea what this means? That says it tried to read the file, but you haven't created the LocoNet connection yet. So it doesn't know what 'LT' means and
By
Ken Cameron
·
#165173
·
|