Locked
Re: Using Dapol semaphore signals signalist sc1 and dp8
Merg ( https://www.merg.org.uk/ ) do a kit for a replacement PCB to fit Dapol semaphore signals so that they operate more logically, with a simple on-off switch, or logic level. This means JMRI and
By
Ian Morgan
·
#154889
·
|
Locked
Re: cmri turnout
suggestions for common ground check?? only see this repeated over and over : Poll ua=0 Receive ua=0 IB=FF FF FF FF 0 0 20 0
By
hpschilling26@...
·
#154888
·
|
Locked
Re: Engine Roster ?
With a large roster, I recommend opening the JMRI System Console (from the Help menu) and after clicking on "Rebuild Roster", watch that window for the "Roster rebuilt, stored in..." message. If no
By
Dave Heap
·
#154887
·
|
Locked
Re: cmri turnout
No need to test this. The node is responding to the polls, so the address is correct, wiring is right, etc. If the C/MRI card configuration is right (which is likely if the polling is working), then
By
Bob Jacobsen
·
#154886
·
|
Locked
Re: Operations: trains to and from staging
Ok Dan,?I¡¯m almost there I¡¯ve now got it so it pulls all the Car Float cars and routes them to Storage. BUT, It won¡¯t move any cars back to the float because the float tracks don¡¯t have the
By
gnguyincalifornia
·
#154885
·
|
Locked
Re: cmri turnout
Hp, Sounding good so far, the outbound message will change as soon as you alter one or more turnouts. My usual test is to set the first couple of even turnouts to normal and the odd turnouts to
By
Ken Cameron
·
#154884
·
|
Locked
Re: Layout Editor issues
Don, ? ?If you are zooming out on your Layout Editor, it's hard to move objects for some reason.? Go back to 100%. Roger
By
Roger Merritt
·
#154882
·
|
Locked
Re: cmri turnout
yes cs1 thru cs64? ?... sensors are working ... yes outputs labeled ct1 thru ct32 ... the following is the only messages on the CMRI monitor (repeated constantly) ... Poll ua=0 Receive ua=0 IB=FF FF
By
hpschilling26@...
·
#154881
·
|
Locked
Re: Engine Roster ?
I clicked on rebuild roster, after that the screen went back to the window that reads at top decoder pro. New loco, identify, help. Is it working? I can¡¯t tell? Is that all you need to do. ? Thanks
By
csx1346
·
#154880
·
|
Locked
Re: Using Dapol semaphore signals signalist sc1 and dp8
Hi Wrightstuart... The Dapol semaphores are just a 2-aspect when connected this way. You can just configure each arm using the single output driver as either head or mast (or head controlled mast)
By
Suzie Tall
·
#154879
·
|
Locked
Re: Engine Roster ?
Russ, Have you tried Recreate/Rebuild Roster Index? This rebuilds the "roster.xml" file to an index of the actual loco files in the "roster" folder found at Roster Location. Note that: - The rebuild
By
Dave Heap
·
#154878
·
|
Locked
Re: WiThrottle Roster display of non decoder entries
Thanks Mark! Roger
By
Roger Merritt
·
#154877
·
|
Locked
Re: Layout Editor issues
3. Delete is the correct option. This deletes the panel from your current run of JMRI and NOT from your files. You can just reopen the panel again if you want without the need to restart JMRI. --
By
Peter Ulvestad
·
#154876
·
|
Locked
Re: Layout Editor issues
Don, 1. Select the group, use "Tools >> Translate (Move) Selection¡±. This allows you to set the precise move distance. 3. Exit JMRI to close without saving. A panel is not an independent item. 4.
By
Dave Sand
·
#154875
·
|
Locked
Re: WiThrottle Roster display of non decoder entries
Roger, If you look at the right side of the WiThrottle Server window, you will see a pull-down menu indicating the roster group that is displayed by Engine Driver and WiThrottle. You can define a
By
Mark Granville
·
#154874
·
|
Locked
Re: Using Dapol semaphore signals signalist sc1 and dp8
I don't own a Dapol signal, but you may find some help on the Signalist?( http://signalist.proboards.com/board/7/dp8 ) forum. I the semaphore can display just 2 aspects, you would configure the mast
By
Egbert Broerse
·
#154873
·
|
Locked
Re: Change Turnout on my Layout
We just released 4.14 and there were a lot of changes for DCC++ during the last six months. I suggest you update to 4.14 and try again. -Ken Cameron, Member JMRI Dev Team www.jmri.org
By
Ken Cameron
·
#154872
·
|
Locked
Layout Editor issues
So, I'm working through the Layout Editor tutorials. I have part of a real control panel entered. I've noticed two problems. 1. Moving: Even when snap to grid is turned on, and objects started on the
By
Don Weigt
·
#154871
·
|
Locked
Re: Change Turnout on my Layout
This a pure guess: I assume you are using a Layout Editor panel and "Options >> Use Direct Turnout Control" is checked. If so, the right mouse button does the throw action. When the option is not
By
Dave Sand
·
#154870
·
|
Locked
Re: JMRI / DCS240 set up question and why so slow?
Operations Mode The NMRA DCC Standards S9.1, S9.2 & S9.2.1 define the technique for encoding bits and sending data packets to a decoder via the DCC track bus. This bipolar bit stream is also rectified
By
Dave Heap
·
#154869
·
|