¿ªÔÆÌåÓý

Date
Locked Re: Packet Delays and Timeout - SPROG3 and JMRI 4.12
This is how SPROG in programming mode works. When you are programming (Read or Write) track power is OFF and you are using the programming track power levels. The whole layout/track you are linked
By thomasmclae · #154130 ·
Locked Re: Raspberry Pi 3 Horse Power?
Dennis, I agree with the maybe, depends a lot on HOW you're planning to automate. I use JMRI Dispatcher for my layout, and I've had 5 trains scheduled, with 3 active at once, with no issues running on
By Steve Todd · #154129 ·
Locked Re: Raspberry Pi 3 Horse Power?
Dennis: I would say maybe... It all depends on just how many options the software has to deal with. Since you're posting here timing will be an issue, Java is interpreted which slows operation. The Pi
By jimalbanowski · #154128 ·
Locked Re: Panel Pro - looking for up to date Tutorial for CPE
John, Using CPE and SML is fine. Doing so DOES change how the SML is created. ¡°Automatic" generation of SML is based on the block topology defined by the Layout Editor track plan. "Manual" creation
By Dave Sand · #154127 ·
Locked Ops: "Percentage of custom loads generated by staging"
I am a little confused by this option on the Schedules page. 1) Does it only apply to the current spur, current schedule, or universally? 2) If it applies to the current, does it apply to all of the
By Jon Schmidt · #154126 ·
Locked Re: Initial setting of sensors in Layout Editor
Thanks Steve & Ken. Thats my first visit to Routes. Works a treat? !
By Paul Townsend · #154125 ·
Locked Re: Operational concept for a single operator #operationspro
Scott....all that makes sense and helps me a lot. I understand how the second train works as long as it is moving in the same direction following the first train. How about if the two trains are
By Paul Davidson · #154124 ·
Locked Re: Initial setting of sensors in Layout Editor
There is a script called SetAllUnknownSensorsToInactive that is part of JMRI.? I use it for my testing.? You can have it run at start up by defining it in the Start Up section of the Preferences.
By Dale Gloer · #154123 ·
Locked Raspberry Pi 3 Horse Power?
Does the RPi 3 or 3+ have enough horse power to run a large HO layout with automated trains? Say there are two large independent loops with staging yards, one with 2-4 trains and the other with 4-6
By Dennis Cherry · #154122 ·
Locked Re: Initial setting of sensors in Layout Editor
You have a few options. For Internal sensors, there is an option to set them to initialize to INACTIVE. But for 'real' sensors, the issue is getting the status from the layout. Here it depends on the
By Ken Cameron · #154121 ·
Locked Re: Packet Delays and Timeout - SPROG3 and JMRI 4.12
Hi All, No Sprog hardware but in an earlier message Rockpro says "Thinking all this might be endemic to some of the other warnings and things". What warnings are these? Is there any weird activity in
By Steve Young · #154120 ·
Locked Re: Initial setting of sensors in Layout Editor
Hi Paul, create a new route, PanelPro > Tools > Tables > Routes > Add Select any turnouts / sensors you'd like setting and their states and save the route. then go to? PanelPro > Edit > Preferences >
By Steve Young · #154119 ·
Locked Re: Packet Delays and Timeout - SPROG3 and JMRI 4.12
Same here.?? Pi-Sprog (just got it the other day).??? Using Steve Todd's image on a Raspberry 3 B+.?? Everything works great except track power goes off automatically goes off randomly for no
By Bob Morningstar · #154118 ·
Locked Initial setting of sensors in Layout Editor
At start up sensors are set to condition "Unknown". Is it possible to set them to "Inactive" at start up?
By Paul Townsend · #154117 ·
Locked Re: Defining a Departure Track
Hi Jon,? Thanks very much.? I've no idea how I missed that.?? Chris
By Chris Mawdsley · #154116 ·
Locked Re: Panel Pro - looking for up to date Tutorial for CPE
Dick Thanks you for the EXCELLENT reply dated Dec 2nd it has opened my eyes to the differences in the different JMRI design systems. I agree with Alan B Pearce¡¯s comments ¡° it should be in FAQ¡±
By John Pearson · #154115 ·
Locked Re: Operational concept for a single operator #operationspro
Hi Paul, Fundamentally JMRI is setup to move a railcar once per session.??A person would?Build all the Trains at once then print out the Manifests and Switchlists for the Trains and Locations (the
By aardtechus · #154114 ·
Locked Re: Operational concept for a single operator #operationspro
Hi Paul, Sorry for talking so long to reply.? Sometimes work gets in the way of trains? :) Looks like you took care of #1. For #2 - yes, if you want the?next train to pick up the cars the previous
By aardtechus · #154113 ·
Locked Re: Unable to launch JMRI version 4.12
Dave Thanks - that fixed the problem. Regards Roger
By Roger · #154112 ·
Locked Re: infinite loop with logix
For what it might be worth, a trick that I have used is to insert a print command into a questionable Logix item. One example snippet, copied from the "Browse" feature of the Logix Table window, looks
By Cliff Anderson · #154111 ·