Locked
Re: ESU in Atlas
As Tom said, V4.10 is too old and has issues. Use at least V4.12, preferably the latest V4.13.x test versions. If you are doing decoder programming, the latest test version is always the best. -- Dave
By
Dave Heap
·
#150558
·
|
Locked
Re: Slot Monitor expansion to 400 slots
Doug S., AJ has stated in the past that dealing with expanded slots adds a significant level of complexity. I think that may be an understatement. As such, adding expanded slot support to JMRI is not
By
billybob experimenter
·
#150557
·
|
Locked
Re: Reading a new loco
BradI don't know if this will help or not but I had this problem and I have a Sprog 3 as my interface so it may be different for you.? I went into Decoder Pro and found the pane at the top that
By
David dareese51
·
#150556
·
|
Locked
Re: engine runs by itself when connected to jmri and sprog
Jim If you go to Decoder Pro and click on the loco in your roster and then click on basic there is a pane labeled Power Source Conversion.? Change this to NMRA Digital only and then write the
By
David dareese51
·
#150555
·
|
Locked
Re: engine runs by itself when connected to jmri and sprog
Jim, ? ? The manual it came with should tell you.? Also DecoderPro will have info on it and you can change it there. Roger
By
Roger Merritt
·
#150554
·
|
Locked
Re: engine runs by itself when connected to jmri and sprog
Thanks for the info, however how do you turn off the analog on the loco Jim Volmer Sr wrote:
By
Jim Volmer Sr
·
#150553
·
|
Locked
Re: I/R detectors
Jon, I used the TCRT5000's to build across the track detectors for staging. They're so cheap, I broke them apart with the detector at trackside, and THREE emitters wired in series diagonally across
By
Greg Komar
·
#150552
·
|
Locked
Re: Reading a new loco
Hi Peter, Thanks...that was the problem.? Just a new user to Decoder Pro, so I'm still in the learning curve stage.? ?I can read my loco now, throttle still will not work as it will not allow me to
By
bradburt@...
·
#150551
·
|
Locked
EPrompt change
How do you change the Eprompt number in JMRI? It keeps telling me I have the wrong EPrompt.
By
Wayne Yount <s.w.yount@...>
·
#150550
·
|
Locked
Re: SE8C - Adding Signal Heads as Turnouts to xml file
They¡¯re the high and low parts of the SE8c Head address. Bob -- Bob Jacobsen rgj1927@...
By
Bob Jacobsen
·
#150549
·
|
Locked
Re: Multiple turnouts on one address using functions?
For a starting point, if you want to try the power of a script before jumping full in, take a look at either of the RocoCrane scripts written by Nelson Allison and Bob in 2009 that are provided in the
By
Cliff Anderson
·
#150548
·
|
Locked
Re: Layout editor and block numbering problems
I've just created ?PR #5639: Change "Add Block" sequential names algorithm
By
George Warner
·
#150547
·
|
Locked
Re: Reading a new loco
And the settings? Are they your command station etc or set to internal? David Klemm Sent from my iPhone 8 Plus ________________________________ Sent: Sunday, August 12, 2018 19:20 To:
By
David Klemm
·
#150546
·
|
Locked
Re: Reading a new loco
Did you open your preferences and check the defaults tab? Make sure nothing is set to internal. -- Peter Ulvestad JMRI Users Group Moderator - http://www.jmri.org ( http://www.jmri.org ) Tam Valley
By
Peter Ulvestad
·
#150545
·
|
Locked
Re: Reading a new loco
I'm using 4.12 not 4.10? any other suggestions?
By
bradburt@...
·
#150544
·
|
Locked
Re: I/R detectors
You can increase the current up to max, or decrease the pull up on the phototransistor.
By
Steve Spence <greentrust@...>
·
#150543
·
|
Locked
Re: Multiple turnouts on one address using functions?
Don, I suspect that you tried saving it to the install location which the OS may have blocked. I would save the script in your user files location. Select "Help >> Locations" and click on the "Open
By
Dave Sand
·
#150542
·
|
Locked
Re: Engine Driver Consists & functions
Ok, That probably eliminates one explanation. Can you send a screenshot of your Engine Driver throttle page (with the consit selected) to my email address akersp62@... Thanks Peter (Brisbane
By
Peter Akers
·
#150541
·
|
Locked
Re: Multiple turnouts on one address using functions?
Dave, Had a little time today and played with it. Cut and pasted your script into Panel Pro's script entry. Had to change the Long Address to true - for some reason, I haven't had any luck using short
By
Don Babcock
·
#150540
·
|
Locked
Re: Layout editor and block numbering problems
This is the undefined user name problem mentioned by DaveS. Is this the "Block Name" combobox in the editor panel? Playing with this and looking at the code it appears that you have to select the
By
George Warner
·
#150539
·
|