开云体育

Date
Locked Re: Turnouts not responding and JMRI in order questions
Hi George, You don't need to have an internet connection to see the JMRI help pages. If you get stuck on a particular JMRI window, go to *Help > Window Help.* This will bring up the help screen for
By Steve Young · #151177 ·
Locked Re: Power Pro connecting to Macbook Pro issues
Taking this topic back to the original thread... Ron, As all have said, it looks like you may have one-way communication with the Power Pro. There are several possible causes, but we need you to
By Dave Heap · #151176 ·
Locked Re: Scripts
Right, and this is why that information appears in the LocoNet logs. The only question I have when getting the information via LocoNet is why do the reporters not get automatically created. It is
By Paul Bender · #151175 ·
Locked Re: PanelPro saving and load problems and findings, and drawing track
I forgot to add. In Logix don't forget to use parenthesis to separate the logic statements . E.G (A or B) and ( C or (D and E)) Chris
By SwissChris · #151174 ·
Locked Re: I am unable to read what type of decoder from the program track and mainline on LokSound and Broadway Limited decoders. I can read the Digitrax decoders.
Yes, but we also 1) have the command station set to n-scale and 2) tried the HO setting with no change in behavior. Paul
By Paul Bender · #151173 ·
Locked Re: PanelPro saving and load problems and findings, and drawing track
Being new to JMRI and DCC myself, and I'm also doing the same as you and doing the design on a different computer to the one running my DCC. I have had a few problems myself, but I found these
By SwissChris · #151172 ·
Locked Re: I am unable to read what type of decoder from the program track and mainline on LokSound and Broadway Limited decoders. I can read the Digitrax decoders.
Peter, This is something else we need to talk about here. Everyone keeps stating the programming track boosters are required, but are able to read without any programming track booster at all.
By Paul Bender · #151171 ·
Locked Re: Macbook Pro issues follow up
Ron, Unfortunately you started a new topic with this, which makes it difficult for us to review where we started, what you are doing and even what hardware you are using. I'm taking my responses back
By Dave Heap · #151170 ·
Locked Re: Scripts
The LocoNet logs Gabor has uploaded include the transponding messages. These are being decided by the standard LocoNet monitor code, so we know the LocoNet messages are of the same type BDL168s will
By Paul Bender · #151169 ·
Locked Re: I am unable to read what type of decoder from the program track and mainline on LokSound and Broadway Limited decoders. I can read the Digitrax decoders.
Any chance the PS2012 is set for N scale output voltage which is lower? Tom in Texas
By Tom in Texas · #151168 ·
Locked Re: I am unable to read what type of decoder from the program track and mainline on LokSound and Broadway Limited decoders. I can read the Digitrax decoders.
Paul, Just for perspective, my club uses a DCS200 powered by a PS2012 along with a PTB100 and we can read ESU decoders as well as Paragon 2 and other decoders.PowerPax boosters were removed as they
By Peter Ulvestad · #151167 ·
Locked Re: PanelPro saving and load problems and findings, and drawing track
Don, Sorry that I missed your posting on 7/24. The easiest way to develop on one machine and run the layout on a different one is using a cloud based file sharing setup such as
By Dave Sand · #151166 ·
Locked Re: I am unable to read what type of decoder from the program track and mainline on LokSound and Broadway Limited decoders. I can read the Digitrax decoders.
Peter, Possibly. It is also possible that there is something about the polarity of a DC power source for the DCS100 and DCS200. ( we didn’t try swapping that actually... ) I have to wonder with
By Paul Bender · #151165 ·
Locked Re: Scripts
I have just uploaded the log file I promised using the latest update of JMRI (though I think the update have made no change in it). Paul, What you are saying sounds logical. If I had been feeling
By halasz · #151164 ·
Locked Re: Macbook Pro issues follow up
There'll only be an item there if a newly installed kernel extension is being blocked. -- Dave in Australia The New England Convention
By Dave Heap · #151163 ·
Locked Re: Scripts
Gabor, With the tool showing the right results, that does confirm the hardware setup. The bit about the LS* showing says we are getting some of the messages right, we see it as a block sensor, which
By Ken Cameron · #151162 ·
Locked Re: I am unable to read what type of decoder from the program track and mainline on LokSound and Broadway Limited decoders. I can read the Digitrax decoders.
Thank you Paul for meeting me at the Club and helping with the trouble shooting. I hope we have helped other folks out there. Again a big thanks Paul and everyone else out there for their input.
By cwt2168@... · #151161 ·
Locked Re: I am unable to read what type of decoder from the program track and mainline on LokSound and Broadway Limited decoders. I can read the Digitrax decoders.
Paul, I find it hard to believe the PS2012 is the cause of some decoders not reading. An AC voltage would be converted to DC in the DCS. It may be there are issues with his power supply. -- Peter
By Peter Ulvestad · #151160 ·
Locked Hornby TTS Sound Decoder Profile - updated
I have recently purchased two of the separately available TTS sound chips - a class 31 and class 37. I tried to add them into decoder pro using version 4.13.2. Although it recognised them as TTS
By Brian Jackson · #151159 ·
Locked Re: I am unable to read what type of decoder from the program track and mainline on LokSound and Broadway Limited decoders. I can read the Digitrax decoders.
Hello All, Show Quoted Content
By Paul Bender · #151158 ·