Locked
JMRI Upgrades
#upgrading
Layout location has no internet connection. Can JMRI be upgraded with the executables off line?
Thank you
Allan
Stony Plain Museum
By
Allan Altheim
·
#216999
·
|
Locked
Re: Lenz LZV200 v4 and 63 functions
#lenz
I'm not sure where any of the code is as far as getting to production. That's why I'm asking for an example, so I can test.
And thanks go to Brett Hoffman for the JMRI changes.
By
Steve Todd
·
#216998
·
|
Locked
Re: Figuring out where I need to place my "blocks"
#blocks
Just a note from a guy who took a 28 block DC layout to a 48 block DCC? layout by isolating the turnouts.? For single turnouts, place a signal at least 40 scale feet from the points end of the
By
Phillip Sifers
·
#216997
·
|
Locked
Re: Lenz LZV200 v4 and 63 functions
#lenz
I’ll look at this tonight. Do I need an updated WiThrottle?
Oh, and THANKS
Phil G
By
Phil G
·
#216996
·
|
Locked
Re: NX Entry/Exit pairs used in LogixNG do not get put back into logixNG when restarting and reloading the panel.
#logixng
#entryexit
John,
A2 is toggling the state of the NX. Since it is active based on the if, the new state will be inactive.
The Return statements are not needed, return is automatic.
Dave Sand
By
Dave Sand
·
#216995
·
|
Locked
Re: Possible bug doing a Reset / USER PRESET 1 on a TCS WOW-121 Steam Decoder.
#tcs
Good morning Bob,
Any news? I know that to perform this Nuclear Reset (AKA USER PRESET 1 RESET) CV201, CV202, CV203, and CV204 must be written in order with the appropriate values.
Would you expect
By
Tim Kelley <tim.kelley@...>
·
#216994
·
|
Locked
Re: Lenz LZV200 v4 and 63 functions
#lenz
All,
Changes have been made in JMRI WiThrottle Server, WiThrottle and EngineDriver to (hopefully) handle the higher functions (or at least quietly ignore them).
Can anyone share a Roster Entry or two
By
Steve Todd
·
#216993
·
|
Locked
Re: NX Entry/Exit pairs used in LogixNG do not get put back into logixNG when restarting and reloading the panel.
#logixng
#entryexit
Thank you for the solution to my issue described above.
OK I have updated to version 5.3.5 and the issue has gone away. Now I want to set a pair active using the following logixNG
I have:
! A? If
By
John Figie
·
#216992
·
|
Locked
Re: NX Entry/Exit pairs used in LogixNG do not get put back into logixNG when restarting and reloading the panel.
#logixng
#entryexit
I am running version 5.2 Production Release. So you say I need to use a a "Test" Release? That seems strange but I will try it.
By
John Figie
·
#216991
·
|
Locked
Re: RFID Connectivity
#rfid
Steve,
Jerry's sketch works, but he made custom changes to the MFRC522.cpp. I haven't looked into his changes in-depth, but they should also work on the 8266. I will let him elaborate. The good news
By
Thomas Seitz
·
#216990
·
|
Locked
Re: RFID Connectivity
#rfid
Jerry
Thanks for your reply, I will have another go as per my last post.
However, I was very interested in your use of an ESP32 and WiFi. Tom and I have been trying WiFi with a WeMos D1 R2, but
By
Stephen Johnson
·
#216989
·
|
Locked
Re: RFID Connectivity
#rfid
Tom, Jerry
I am pretty sure I have selected the MERG Concentrator input, but I wilk make doubly sure! The message I'm getting in the RFID Command Monitor is consistent with it being unselected. When
By
Stephen Johnson
·
#216988
·
|
Locked
Re: NX Entry/Exit pairs used in LogixNG do not get put back into logixNG when restarting and reloading the panel.
#logixng
#entryexit
John,
What version of JMRI are you running? You need to be running at least test version 5.3.2.
Dave Sand
By
Dave Sand
·
#216987
·
|
Locked
NX Entry/Exit pairs used in LogixNG do not get put back into logixNG when restarting and reloading the panel.
#logixng
#entryexit
I don't know if this is a bug or if I am doing something wrong.? I have a logixNG that uses an NX Entry/Exit pair in some of the logixNG for example:
I have:
! A? If Then Else, Always execute
? if
By
John Figie
·
#216986
·
|
Locked
Re: RFID Connectivity
#rfid
Steve,
I tend to agree with Jerry here. We solved this situation for him with this. Ensure that the connection type is MERG Concentrator (A-H), whether the connection is serial or network
By
Thomas Seitz
·
#216985
·
|
Locked
Re: New user to JMRI Ops Pro requesting assistance
#operationspro
Mel,
You may, of course, employ whichever tools this program makes available (there are many).? If you want to avoid schedules for now, you would still have some options to prevent the
By
Pete Johnson
·
#216984
·
|
Locked
Re: having issues with JMRI not routing cars
#operationspro
Yes Pete thank you for your advice I did make some of the changes you suggested and it also helped with a few other minor problems I was seeing.
So again thank you and Yes I will keep using the
By
Trackwalker09@...
·
#216983
·
|
Locked
Re: having issues with JMRI not routing cars
#operationspro
Hey Trackwalker,
I am glad you were able to get the Build Report Detail Level turned up enough so that help could be offered.? I think it was from the lower level of detail that I was missing the
By
Pete Johnson
·
#216982
·
|
Locked
Re: RFID Connectivity
#rfid
Stephen -
I have been trying this too (although with ESP32 over wifi), and when I got “unknown reply of length 16” it was because I did not have MERG concentrator selected in the RFID preferences
By
JerryG
·
#216981
·
|
Locked
Re: Looking for an HO Overland Medco #4 Willamette...
We would like to point out that this list is for discussions related to JMRI, and is intended to be a place that people, particularly beginners, can turn to for help with their JMRI problems from more
By
Peter Ulvestad
·
#216980
·
|