And John recommends Echo be on.
..P
toggle quoted message
Show quoted text
-----Original Message-----
From: Robin Becker [mailto:rbgroups@...]
Sent: November 6, 2002 9:38 AM
To: jmriusers@...
Subject: [jmriusers] LocoBuffer jumpers
Someone asked about the locobuffer jumper settings. Here's
the info based
on the schematic John Jabour posted:
JP1 Baud rate
1-2 19200
2-3 57600
JP2 Echo
1-2 off
2-3 on
JP3 Operating Mode
1-2 MS100 compatibiity mode
2-3 LocoBuffer mode
JP4, JP5 Programming
1-2 Normal
2-3 Program
Notes:
1. I think that you need to cycle power after moving the
jumpers before the
changes take effect.
2. JP4 and JP5 should always be 1-2 unless you are
reprogramming the PIC.
Robin Becker
Tucson, AZ
D&RGW Model Railroad Layout
To unsubscribe from this group, send an email to:
jmriusers-unsubscribe@...
Your use of Yahoo! Groups is subject to