There's a known issue with the possibility of "Programmer in Use" if you Write All Sheets on any pane rather than Write Full Sheet on the CVs pane. This has been around for along time and is not yet resolved.
--
Dave in Australia
toggle quoted message
Show quoted text
On 11 Dec 2018, at 9:47 PM, Mick Moignard <mick@...> wrote:
I just upgraded my JMRI to 4.13.6, and I can¡¯t now get it to write indexed CVS in a Soundtraxx ECO-100 UK decoder. Non indexed CVS are ok, but as soon as it hits an indexed one I get first a 308 error and then a JMRI programmer in use error (not the 302 system programmer in use error), and the console shows a stack trace.
I¡¯ve localised it to Digitrax support. I¡¯ve tried connecting the DCS240 as both DCS240 and DCS100 with the same result, all via a LocobufferUSB. I can successfully write al the CVS to the loco with a SPROG, so the loco and decoder are not at fault.