¿ªÔÆÌåÓý

Locked Re: 2 way working on single track - signals


 

Hi Peter
In tools->Sections>Tools->"Set Direction Sensors In Logic"
If that fails:
tools->tables->Signals->SignalMastLogic", find the signal ->edit->sensor tab,
and select the sensors you want "Apply"
Or via the LayoutPanel: Alternate Click on the mast to bring up the
menu->"signal mast logic : {mastname}"-> find the destination mast in the
list->edit -> select the sensors tab, add the sensors you want and "Apply"
Steve G

---------- Original Message ----------
From: "Peter Riggall via Groups.Io" <petermmrs@...>
Date: July 26, 2018 at 7:54 AM


My end-to-end layout includes a mainline single track designated for two way
working.

It is described in a JMRI Layout Panel that includes Blocks that have
occupancy sensor feedback.? Signalling uses Signal Masts to a definition that
I have created for Australian Victorian methods and I have also defined
Sections (using auto generate) for each signal pair and set up Transits to
route from West to East.?

I would expect the signals in the opposite direction to remain RED, however,
as a train traverses and vacates the Block that the opposite Signal protects,
the signal changes from Red to Caution.

The Sections documentation of JMRI indicates that the internal direction
Sensors "may be used in signal logic to force signals for travel in the
direction opposite to the allocated direction to RED", but I cannot find
anywhere how to achieve this.

Any help would be greatly appreciated.

Thanks in anticipation.

Peter