A bunch of DXers and Contesters I had work week regular lunch meet.? We had a saying: If your tube doesn¡¯t have handles you aren¡¯t squat. (Polite version.)
?
QRO comes in more than one form.? The most common are high horsepower cars. Another is powerful computers.
These guys are a waist of time on the internet.? Where do they get the time and money to build this stuff.? When I see them discussing stuff that is not legal,? I just delete it.
You know, I figured I'd get something like this ( hits self in head ).? Sheesz
Andy? K9ATX
On 10/2/2023 11:19 AM, Joe WB9SBD wrote:
Something efficient and has very low losses.
Joe WB9SBD
On 10/2/2023 10:48 AM, DupyRail wrote:
Wondering what kind of antenna is used that will handle this much power?
A
On 10/2/2023 10:33 AM, Jim VE7RF wrote:
I designed this amp (back in 2007) for a buddy, who is now SK. Current owner is in MT. It uses a custom 253 lb Dahl plate xfmr and 24 x 3900uf lytics. Vac relays used for
the input + cut off bias. Paralleled Jennings RJ2B's used for the output. We tested the manually tuned, tuned input with a 800 watt CCS cxr for 10 mins, on each band. Input swr is dead flat across all bands. Triple wafer model 85 switch used for the 12 kw
PI net. Multronics MI-14 1/2" tubing coil used for 160-80-60-40-30m. HB 1/2 tubing coil used for 20-17-15-12m. This is a 9 band amp. 1000 pf @ 15 kv jennings tune cap. 3000 pf @ 5 kv jennings load cap. Bias is adjustable, on the fly with a 20 position rotary
switch. Dual line section bird, with 25 kw forward slug and 1 kw reverse slug. Pep board also installed. Kicks offline if reflected power too high. 10 kw out with 500w of drive. 12 kw with 600 watts of drive. 7-16 DIN output connector. I also have a spare,
nib blower, on my shelf. 253 lb dal xfmr has pri taps at 198-208-218 vac....and also 230-240-250 vac. Sec taps at 2300, 2900, 3900, 4600, 5000, 5400 vac. ( single phase 60 hz). 3 x 300 amp contactors used on the 240 vac input. One per each leg..and the 3rd
one used for the step start. Separate step start and variac used for the fil xfmr. There is only 5600 hrs on the hour meter. You need 200 amp service...and also a 100 amp breaker installed in the main 200 amp panel...and a min of 3 ga copper wire from main
panel to amp.
If interested, contact the seller below.
A SUPERBLY HAND BUILT 3CX-6000A7 HF AMPLIFIER IN A 6 FT RACK ON WHEELS. DESIGNED BY A PROFESSIONAL ENGINEER. PETER DAHL HV SUPPLY WITH TAPS DELIVERS UP TO 8000 VDC AT 3 AMPS.
ANY TRANSCEIVER WITH A 500 WATT INTERMEDIATE AMP CAN PRODUCE OVER 10KW OUTPUT. INPUT AND OUTPUT BAND SWITCHES WITH TUNED PI NETWORKS FOR ALL HAM BANDS 160-12 METERS AND TUNABLE TO OTHER HF FREQUENCIES 3.5-24 MHZ. HUGE ADJUSTABLE OUTPUT VACUUM CAPS AND VACUUM
RELAYS. ADJUSTABLE BIAS FOR BOTH LINEAR AND CLASS C. EXTENSIVE METERING, PROTECTION CIRCUITS AND FUSING THROUGHOUT. OVER $10,000 IN PARTS AT 2010 PRICES AND UNTOLD HOURS WERE SPENT BUILDING AND PERFECTING THIS INCREDIBLE MACHINE. WE CALL IT THE MONSTER AMP.
ASKING $10,000 OR BEST OFFER. WE HAVE DETAILED PHOTOS. ONSITE DEMONSTRATION OF THIS AMP¡¯S OPERATION AND CAPABILITES IS AVAILABLE IN MONTANA. TOO HEAVY TO SHIP. SERIOUS BUYERS CALL 406-240-5428 OR 406-830-6360 FOR MORE INFORMATION. NOTE: OPERATION HIGHER THAN
1500 WATTS IN US HAM BANDS VIOLATES FCC RULES.