Re: Electrical question
I am quite surprised that the electrical connections are so poorly defined. I sent an email to Felder tech support asking for guidance. Wouldn¡¯t it be wonderful if they responded as quickly as the
By
John Hinman
·
#137126
·
|
Re: Tripping breaker. K700s
I am leaning towards that. It is strange that if I flip the breaker it resets the saw? <mikelis.vindavs@...> wrote:
By
Paul Jones
·
#137125
·
|
Re: Tripping breaker. K700s
Hi Paul, Perhaps the microswitch for the blade cover has dust in it and doesn¡¯t always reset when the cover is closed?
By
Mi?elis Vindavs
·
#137124
·
|
Re: Felder Diamond Blade - saw marks
I use the Tenryu 300mm blade and glue up off the saw. Kappa 400 Bill Belanger
By
Bill Belanger
·
#137123
·
|
Re: Tripping breaker. K700s
Hi Paul, I don¡¯t see how a blade change can result in tripping the breaker in the main electrical panel. May be just a coincidence. To start, I would measure the current to determine if you have a
By
imran
·
#137122
·
|
Re: Felder Diamond Blade - saw marks
I have the Felder blade and 2.0 riving knife. As for saw marks Felder has a setup guide and it allows for returns of any blades that cause excessive saw marks. Mine is really smooth. Almost zero marks
By
Andy
·
#137121
·
|
Re: Felder Diamond Blade - saw marks
Hello, I have the Felder branded version. My experience so far has been the same as yours ¡ª I love how quiet it is, but it leaves saw marks on almost every cut. It was the first blade I used when I
By
Mi?elis Vindavs
·
#137120
·
|
Re: Electrical question
David:Thank you for the information and the clarity. Last year,?I purchased a?Solberga drill press - 3-phase, Swiss machine, and needed to add several?3-phase?dedicated outlets. Scheduling an
By
Mike D. <mjcdorsam@...>
·
#137119
·
|
Felder Diamond Blade - saw marks
hey guys, Quick question to those who have used the Felder Diamond blade. I recently obtained the AKE diamond SuperSilent 3 Universal from SauterShop.? I believe the Felder diamond blade is just a
By
abruptlly@...
·
#137118
·
|
Re: Electrical question
My machine came with 4 wire cable. 2 black and 1 grey (besides the ground). Felder tech told me it isn¡¯t guaranteed which cable will be connected to T3. He told me to open the electrical box and
By
netanel.belgazal@...
·
#137117
·
|
Re: Electrical question
I have three 3-phase Felder machines and they all came with 5 wire cords (no plug) with instructions that clearly stated on two of them that the ¡°neutral leg (blue wire) is for European use only.¡±
By
Larry
·
#137116
·
|
Tripping breaker. K700s
Yesterday I did a blade change from my groove cutter to a saw blade. While the groove cutter was off I vacuumed out the cabinet. When I put the new blade and riving knife back on and closed the
By
Paul Jones
·
#137115
·
|
Re: Electrical question
One more suggestion. 3-Phase wiring is typically colored Black, Red, and Blue so you might ask your electrician to use those code-standard color choices, and wire up T1 to Black, T2 to Red, and T3 to
By
David P. Best
·
#137114
·
|
Re: Electrical question
Thank you, David Best. Great info! -- John Hinman Boise ID K700S and A941
By
John Hinman
·
#137113
·
|
Re: Electrical question
The PP will have connection terminals as follows: L1, L2 - these are the inputs to the PP and where you connect the 230VAC supply line from your breaker panel T1, T2, T3 - these are the output of the
By
David P. Best
·
#137112
·
|
Re: Electrical question
Thanks, Imran! Jacques, Christmas will come in September. I am excited about the new saw. Once in a while I make impulse purchases, and this is one of the bigger ones. -- John Hinman Boise ID K700S
By
John Hinman
·
#137111
·
|
Re: Electrical question
John, Apologies for distracting this thread, but I am curious to know how it feels to experiment ? Christmas in Summer ?? ? Congrats on the new equipment - I am sure you will enjoy it. Regards,
By
Jacques Gagnon
·
#137110
·
|
Re: Electrical question
Hi John, With PP there is really not a high (voltage) on the manufactured leg as can be expected with Rotary Phase Converters. Even though the PP is super reliable it still does not hurt to avoid
By
imran
·
#137109
·
|
Re: Electrical question
Thanks, guys! I do not yet have the machine, so cannot look at the plug. I will tell the electrician I do not need a neutral. He has a question about a ¡°high leg¡± that I cannot answer - hopefully
By
John Hinman
·
#137108
·
|
Re: Electrical question
Felder 3-phase machines as sold in the USA do NOT require a neutral. David Best DBestWorkshop@... https://www.flickr.com/photos/davidpbest/collections/ https://www.youtube.com/@David_Best
By
David P. Best
·
#137107
·
|