Re: Is it the RELIGHTER module that failed on my Norcold ?


 

开云体育

Yves


The green light is triggered by the electrical conductivity of the propane flame ( flames are a plasma with high electrical conductivity). If the green light is one without a flame then something else is completing the circuit. That usually is soot? buildup on the igniter ( the ceramic insulator withethe spark electrode protruding from it). Check the ceramic and clean it and see if that helps. If not- then it is a failure in the relighter.?


Sam


02EVC

On 8/10/2022 2:49 PM, Yves Desilets via groups.io wrote:

Hi,

I'm facing a MAJOR problem with my Norcold 3163 fridge and I really need your hefp. My fridge suddenly stopped working on gas !!! When I push on the gas selector in the front of the mainboard, the GREEN light shows up without me touching the safety valve RED button and it stays lit that way without hearing a 'poof' sound from the burner showing me that the burner would be on ! There is no flame in the burner at all. It's like everything was dead on the fridge, just the GREEN light that stays lit. What could it be ? It was working very well before that thing happened. I checked the fuses on top of the fridge, especially the 1 AMP one and all is fine. It's also working well when connected to AC (electric). I cannot have it checked by somebody 'cause they are all booked for a month and I need to have it repared as soon as possible....Could it be the RELIGHTER ? What module do you think could cause such a thing ? When I push on the RED button, there's no sound and no flame. It's not lighting. Just the green light that shows up without flashing (solid green). What module is responsible of giving a flame and a click when pressing the safty valve button (red one) ? Thanks for your help....I'm really despaired !!!

Yves
'97EVC

Join [email protected] to automatically receive all group messages.