Re: Samsung QE series & Samsung IP Display v1.3 driver
#samsung
Hi With which processor do you want to use this module? I use this module but not for the same Samsung reference and it works on the other hand, I had a problem when I wanted to use it with a PMC3 :
By
Manu
·
#237965
·
|
Re: Interlogix alternative
So are you saying that HAI is no longer available?? It has been a while since I integrated one in a new project but I too have always like HAI products.? Seems like most security panels come with
By
Steve Kuehn
·
#237964
·
|
Samsung IP control in a post 200 Database world
#samsung
What is everyone doing for IP control of Samsung? The Samsung IP driver from the application market isn't being updated to work with the new database. Has everyone switched to certified drivers? I
By
ftvenezia@...
·
#237963
·
|
Re: Interlogix alternative
+1 for Elk I even installed one at my own house. I don't really need an alarm system per se but it is a great way to define whether the home is occupied or not (armed away vs. armed stay or disarmed)
By
jbasen
·
#237962
·
|
Re: Interlogix alternative
We use ELK, and it is extremely reliable.? I've been Lately, I've been hounding Crestron to add it to Home as a supported system. I believe that it will be integrated with that soon. We don't use
By
Brian Matson
·
#237961
·
|
Re: Biamp Control Subnet
We did something like this and I want to say we had to turn off (disable) IGMP Snooping on the subnet.
By
dedicatedsystems
·
#237960
·
|
Re: Lexicon MC-10
1. Who says it needs to have XLRs? 2. I said 1U or 2U 3. There is so many products and options that are 4U, with or without XLR. There are none in 2U or under that has all the current HDMI AV formats
By
ZS
·
#237959
·
Edited
|
Re: Lexicon MC-10
LOL.? Could you even get all the XLRs on a 1U.
By
John Gabler
·
#237958
·
|
Re: Lexicon MC-10
There are MC-10 modules available. Got them from their site.? There is both an RS232 module and an IP module.? I installed one about 3 months ago.? FYI you can not simultaneously have the ethernet
By
John Gabler
·
#237957
·
|
Re: Interlogix alternative
SB2000AM is required for Concord series.? There is a module in the DB.? The problem is getting one.? GE stopped manufacturing in December and Distys have not had GE/ITI parts since then.? There
By
John Gabler
·
#237956
·
|
Re: Samsung QE series & Samsung IP Display v1.3 driver
#samsung
No, but I haven¡¯t had a chance yet to go back and try using port 1516 as has been suggested, although, considering this driver is specifically listed as for this ¡°The Frame¡± model, I don¡¯t see
By
rickwookie
·
#237955
·
|
Re: Samsung QE series & Samsung IP Display v1.3 driver
#samsung
Good morning Rick, Have you had any luck with this driver?? I am getting the same thing.? Very frustrating...Thanks. -- Matt Grisafe AV Programming Associates www.avprogramming.com (
By
AVPA
·
#237954
·
|
Re: Setting a Simpl# Array Size based on a constant in Simpl+?
But why.... Limitations of the S+/S# mechanism prevent you from doing this easily as S+ automatically instantiates the S# class using the default constructor and you don¡¯t have control over when.
By
Neil Dorin
·
#237953
·
|
Re: Interlogix alternative
I am looking through this old thread and wondering about Interlogix SuperBus 2000 Automation module. Would that help in integrating to older GE systems and is there a Crestron module out there for it?
By
TRoberts
·
#237952
·
|
Topics in Home Automation - New Article in Residential Tech Today
My latest article, "How to Know When Events Take Place in a Smart Home¡± is being published by the good folks at Residential Tech Today Magazine on their web site. It is very important for a
By
jbasen
·
#237951
·
|
Setting a Simpl# Array Size based on a constant in Simpl+?
I'm looking to create an array in Simpl# whose size is dependent on a constant in Simpl+. With Simpl+, I can just have the constant be 10, for example, and then point inputs/outputs/arrays to that
By
musichascolors
·
#237950
·
Edited
|
Re: Biamp Control Subnet
Yes, forwarding Port 61415. However, this only works if you have a single DSP on the subnet. If you've got multiple FORTEs or a SERVER and a FORTE, etc., the software will complain that it can't
By
ezrabeegs
·
#237949
·
|
Biamp Control Subnet
Has anyone successfully routed a biamp tesira through the Control Subnet and able to connect with Tesira Software? If so, what ports did you use? Thanks
By
Pusher of Buttons
·
#237948
·
|
CP4 v2.4508.00035 Errors when stoping/restarting programm
Everytime when i Restart my Programms (3 Slots in total) i get tons of those Messages in the errorlog Error: CIPCommandProcessor # 2020-10-28 12:45:10 # SendMessageToTLDM. Error on send. Error Code
By
Dario Dusper
·
#237947
·
|
Re: Launch other Apps from Crestron App
Thanks. Seems like that should have shown up in a Google search. I had no idea it was so simple. [email protected]> wrote:
By
ryan.meissner
·
#237946
·
|