¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date

Re: OT: RG59 as speaker wire??

 

I have female F to tinned pair for sale. Originally intended for touch
panel video, but they will also work for speakers . . .
SandsationalSound.com


_____

From: Crestron@... [mailto:Crestron@...] On Behalf
Of LENREX
Sent: Thursday, June 06, 2013 1:19 PM
To: Crestron@...
Subject: [Crestron] Re: OT: RG59 as speaker wire??




I'm not even going to ask how a RG59 cable got pulled to a speaker location.


--- In Crestron@... <mailto:Crestron%40yahoogroups.com> ,
"wookertee" <wookert@...> wrote:

Has anyone used RG59 as speaker wire?
I remember that MIT used to have a F-connect screw on adapter to speaker
level.

:p don't smirk, it's a take-over job (roll eyes...)


Re: Samsung ME55B IP Control Issue

 

If there is a panel off command, that shuts off the backlight but leaves the
unit on . . .
_____

From: Crestron@... [mailto:Crestron@...] On Behalf
Of hitplay07
Sent: Thursday, June 06, 2013 7:09 AM
To: Crestron@...
Subject: [Crestron] Re: Samsung ME55B IP Control Issue





Hi Corey,

Did you ever figure this one out? I am having the exact same issue. When I
ping the port while the display is off there is no response. There must be
some way to keep it active while the display is off.

Thanks,
Eric

--- In Crestron@... <mailto:Crestron%40yahoogroups.com> ,
cchurch@... wrote:

I can connect to it. Change inputs, adjust volume, etc. However when I
turn it off I can't turn it back on because the ethernet port is dead when
the TV is off. Any ideas how to enable the ethernet port when the TV is off.


Thanks Corey


Re: EISC or touchpanel over WAN

 

I have connected my PRO2 at come with a PRO2 at my workpace over EISC in order to do some monitoring on my home system at work, it worked flawlessly, just have to open the right ports on each side.

--- In Crestron@..., Eric Williams <ewilliams0305@...> wrote:

Is this a really bad idea?



Re: Another samsung ex-link question

 

No ideas?

--- In Crestron@..., "eagrubbs" <eagrubbs@...> wrote:

I am at training for that other company and I have an install going on, so I can't see the real issue. Supposedly the code works and the control works, but there is window that is popping up on the tv screen that states "not available" when the ex-link is plugged in. Samsung support(lol) told the tech that the model could not be controlled by ex-link. Have any of you guys experienced this and can the on-screen pop up be disabled?


D3/SystemBuilder rant/request for help

 

Am I the only one that finds going from Simpl/Simpl+ back to D3/SB
challenging?

I've never taken any classes, but I didn't for LiteTouch or Vantage either.
Is there a guide, PDF, or training video I can watch?

I've got a DIN-IO8 for garage door contacts. I've got an IO8 in the
program, but where do I program the buttons?

What's the D3 equivalent for an One ShotMomentary button?

Why is D3 telling me I can't upload the program because "there's no compact
flash to load runtime/Xpanel browser data to". The program is 42K right
now, and there's no Xpanel interfaces. It uploads fine in Toolbox.

Chris


Prowl for Crestron 3 Series is posted!

 

Just FYI. Andrew Culver was nice enough to post a SIMPL# module on github to show this working. I spent a few hours testing his module, expanding it and writing a help file. No knowledge of SIMPL# is required to make this work, so no fear! The module is small and easy to use.

Go to and follow the directions. You'll be pushing notifications to any app at in no time.

Let me know if you have any questions!

Michael Block


Re: Another samsung ex-link question

 

No ideas?

--- In Crestron@..., "eagrubbs" <eagrubbs@...> wrote:

I am at training for that other company and I have an install going on, so I can't see the real issue. Supposedly the code works and the control works, but there is window that is popping up on the tv screen that states "not available" when the ex-link is plugged in. Samsung support(lol) told the tech that the model could not be controlled by ex-link. Have any of you guys experienced this and can the on-screen pop up be disabled?


Re: OT: RG59 as speaker wire??

 

The amp is an AAE.
Originally this location was a TV, using DM for distribution.
Two CAT5 and a Penta (5x mini-RG59) were pulled to the location.
Now the client wants "better" sound and has requested a sound bar.
I was thinking of using a RMC-200 with the amp, but that seems a tough upsell with 6 TVs in the same situation...

Argh, take-over jobs, the bane of my existence.

--- In Crestron@..., Trey Chamrad <trey@...> wrote:

+1 have also done for zone audio, low wattage, under 100' to 150'

Thanks,
Trey

please excuse typos, courtesy of my Samsung Galaxy S4
On Jun 6, 2013 12:50 PM, "wookertee" <wookert@...> wrote:

**


Has anyone used RG59 as speaker wire?
I remember that MIT used to have a F-connect screw on adapter to speaker
level.

:p don't smirk, it's a take-over job (roll eyes...)



[Non-text portions of this message have been removed]


DSI Tridonic LuxControl

code_radio
 

Hello Group,

I would like you all to cast your minds back to an old lighting system with a protocol called DSI.

I have been trying to find out information about this protocol, but have only found out that it uses encoding known as 'Manchester Encoding'. I have tried to send strings to the interface using rs232 and this type of encoding but have not been successful.

The interface is:

Tridonic DSI 011 LuxControl (for dimming of Tridonic power control)

If there is any information that anyone can give me about this device I would be very greatful. This equipment is very old and is pre DALI.

Thanks in advance.

Regards

J


Re: OT: RG59 as speaker wire??

 

You can always use this:

(RG-59,
262ft) with a POE amplifier

and
an IP streamer.
It'd be expensive, but if you truly can't get a wire there, you can do a
local amp.

As for speaker wire directly on RG-59, I think it'd work at lower volumes,
but it will probably force the amp into a protect mode at high volumes.


On Thu, Jun 6, 2013 at 4:09 PM, sebastian marszalek <s.marszalek11@...
wrote:
**


Cat5 is definitely a life saver!

--
Sebastian Marszalek


[Non-text portions of this message have been removed]



[Non-text portions of this message have been removed]


Re: OT: RG59 as speaker wire??

 

Cat5 is definitely a life saver!

--
Sebastian Marszalek


Re: OT: RG59 as speaker wire??

Paul Cunningham
 

I don't think I've used RG59, but I've definitely used (against my will) Cat5 as RCA audio cable and speaker wire. But according to the "high-end cable = snake oil" crowd, copper is copper amirite? X-)

-----Original Message-----
From: Crestron@... [mailto:Crestron@...] On Behalf Of Trey Chamrad
Sent: Thursday, June 06, 2013 4:22 PM
To: Crestron@...
Subject: Re: [Crestron] OT: RG59 as speaker wire??

+1 have also done for zone audio, low wattage, under 100' to 150'

Thanks,
Trey

please excuse typos, courtesy of my Samsung Galaxy S4 On Jun 6, 2013 12:50 PM, "wookertee" <wookert@...> wrote:

**


Has anyone used RG59 as speaker wire?
I remember that MIT used to have a F-connect screw on adapter to
speaker level.

:p don't smirk, it's a take-over job (roll eyes...)







------------------------------------



Check out the Files area for useful modules, documents, and drivers.

A contact list of Crestron dealers and programmers can be found in the Database area.
Yahoo! Groups Links


Re: OT: RG59 as speaker wire??

Trey Chamrad
 

+1 have also done for zone audio, low wattage, under 100' to 150'

Thanks,
Trey

please excuse typos, courtesy of my Samsung Galaxy S4
On Jun 6, 2013 12:50 PM, "wookertee" <wookert@...> wrote:

**


Has anyone used RG59 as speaker wire?
I remember that MIT used to have a F-connect screw on adapter to speaker
level.

:p don't smirk, it's a take-over job (roll eyes...)



[Non-text portions of this message have been removed]


Re: OT: RG59 as speaker wire??

 

I'm not even going to ask how a RG59 cable got pulled to a speaker location.

--- In Crestron@..., "wookertee" <wookert@...> wrote:

Has anyone used RG59 as speaker wire?
I remember that MIT used to have a F-connect screw on adapter to speaker level.

:p don't smirk, it's a take-over job (roll eyes...)


Re: Samsung ME55B IP Control Issue

 

There is info on this board about using the Wake on LAN feature on these TVs. I've got it working here at my shop. Use WoL to turn the display on, then you can go from there. Works well.

Mike

--- In Crestron@..., cchurch@... wrote:

I can connect to it. Change inputs, adjust volume, etc. However when I turn it off I can't turn it back on because the ethernet port is dead when the TV is off. Any ideas how to enable the ethernet port when the TV is off.

Thanks Corey


Re: Two Processors over WiFi?

 

I've done a commercial job with 14 MC3s, 2 CP2Es and a PRO2.

Depends on the scope and the clients needs...
On 2013-06-06, at 1:07 PM, Michael J Coe <pe2b4nasa@...> wrote:

Good God man you had 12 MC3s?! Lol I know I am still young to Crestron but thats nuts lol

Michael J Coe

On Jun 6, 2013, at 2:51 PM, "Jeff Cunningham" <j.j.cunningham@...> wrote:



Ive connected 12 MC3s (24 zones of A/V with lighting and HVAC)over wireless bridges using IESC and slave with linksys wireless routers configured as bridges, surprisingly I had no problems (proper design up front is key).
Following that I did a single display board room with 2 sources and a DMPS-300C and had nothing but problems. Go figure...
--- In Crestron@..., "LENREX" <lenrex@...> wrote:

Has anybody ever tried to get two processor talking via WiFi? And if so, how reliable was it?

Dealing with a condo design where they might not want to rip up drywall to get a cat5 from the living room to bedroom, but would want control of both rooms with a single program. I was wondering if something like two airports linked up wirelessly might work? Thinking two MC3's in a master/slave setup with one program so we can have one mobile pro program.
[Non-text portions of this message have been removed]


[Non-text portions of this message have been removed]


Re: Two Processors over WiFi?

Michael J Coe
 

Good God man you had 12 MC3s?! Lol I know I am still young to Crestron but thats nuts lol

Michael J Coe

On Jun 6, 2013, at 2:51 PM, "Jeff Cunningham" <j.j.cunningham@...> wrote:



Ive connected 12 MC3s (24 zones of A/V with lighting and HVAC)over wireless bridges using IESC and slave with linksys wireless routers configured as bridges, surprisingly I had no problems (proper design up front is key).
Following that I did a single display board room with 2 sources and a DMPS-300C and had nothing but problems. Go figure...
--- In Crestron@..., "LENREX" <lenrex@...> wrote:

Has anybody ever tried to get two processor talking via WiFi? And if so, how reliable was it?

Dealing with a condo design where they might not want to rip up drywall to get a cat5 from the living room to bedroom, but would want control of both rooms with a single program. I was wondering if something like two airports linked up wirelessly might work? Thinking two MC3's in a master/slave setup with one program so we can have one mobile pro program.

[Non-text portions of this message have been removed]


Re: Anyone have a module for a Bryston SP3 surround processor

Heather Baiman
 

I now have one on my bench as well.

I'm waiting for a callback from their tech support as to whether they or Crestron is working on a module.
Or have you guys already found out the answer?

For those of you with experience with the SP2, any words of wisdom on the control/setup/use of the unit?

TIA

-----Original Message-----
From: Crestron@... [mailto:Crestron@...] On Behalf Of bjhuck74
Sent: Tuesday, May 28, 2013 4:48 PM
To: Crestron@...
Subject: [Crestron] Re: Anyone have a module for a Bryston SP3 surround processor

Jay,

I just discovered the same thing. Did you ever find/build a module for the SP3?

Thanks,
Brian

--- In Crestron@..., Jay Basen <jay.m.basen@...> wrote:

Crestron has a module for the SP2 but I just found out that the protocol for the SP3 is completely different.

Thanks in advance for the help

Jay



------------------------------------



Check out the Files area for useful modules, documents, and drivers.

A contact list of Crestron dealers and programmers can be found in the Database area.
Yahoo! Groups Links


Re: Calculate a checksum

maglite4cell
 

Thanks!

I worked through it and came out with something similar.

--- In Crestron@..., "Chip" <cfm@...> wrote:


Oh, and (potentially) last step:

tx$ = msg$ + CHR(CHK);

//sends your message and checksum byte...

- Chip


--- In Crestron@..., "Chip" <cfm@> wrote:


Then you could use an ATOS symbol in SIMPL with an option of 259d.

If you want to do this in S+, and your bytes are in "msg$", you could do this:

X = 0;
FOR (Y = 1 TO LEN(msg$))
{
X = X + BYTE(msg$,Y);
}
// This gives you a sum of all your bytes in "Y"

CHK = 256 - LOW(Y);

// In case the bytes add up to more than $FF, use LOW

- Chip



--- In Crestron@..., "maglite4cell" <maglite4cell@> wrote:

It uses all of the hex bytes to calculate it the formula is (&#92;x100 - (sum of data bytes))

--- In Crestron@..., Neil Dorin <neildorin@> wrote:

We're going to need to know what kind of checksum you're calculating here.
The API/Protocol document for the product you're integrating should specify
how to calculate it. If you can tell us what product or the specified
calculation we can try to assist you in how to build the calculation in
code.


On Thu, Jun 6, 2013 at 9:15 AM, maglite4cell <maglite4cell@>wrote:

**


Does anyone have an example to calculate a checksum?

Im having a brain fart here....





Re: Calculate a checksum

Chip
 

Oh, and (potentially) last step:

tx$ = msg$ + CHR(CHK);

//sends your message and checksum byte...

- Chip

--- In Crestron@..., "Chip" <cfm@...> wrote:


Then you could use an ATOS symbol in SIMPL with an option of 259d.

If you want to do this in S+, and your bytes are in "msg$", you could do this:

X = 0;
FOR (Y = 1 TO LEN(msg$))
{
X = X + BYTE(msg$,Y);
}
// This gives you a sum of all your bytes in "Y"

CHK = 256 - LOW(Y);

// In case the bytes add up to more than $FF, use LOW

- Chip



--- In Crestron@..., "maglite4cell" <maglite4cell@> wrote:

It uses all of the hex bytes to calculate it the formula is (&#92;x100 - (sum of data bytes))

--- In Crestron@..., Neil Dorin <neildorin@> wrote:

We're going to need to know what kind of checksum you're calculating here.
The API/Protocol document for the product you're integrating should specify
how to calculate it. If you can tell us what product or the specified
calculation we can try to assist you in how to build the calculation in
code.


On Thu, Jun 6, 2013 at 9:15 AM, maglite4cell <maglite4cell@>wrote:

**


Does anyone have an example to calculate a checksum?

Im having a brain fart here....