Re: ADA Suite 8x8 or Suite 18 Module
Search in the files section, there's something there. If that doesn't work I have one I can share with you, think it came from the Yahoo group (yes it's that old...)
By Neil · #256516 ·
ADA Suite 8x8 or Suite 18 Module
Hi all, i'm looking for a module to control ADA Suite 8x8, but I believe the Suite 16 module will work. We were a ADA dealer, but unfortunately they are no longer in business. Any help would b greatly
By andrewb@... · #256515 ·
Re: Doorbell C4 Chime Integrate or replace? Crestron Home
If you are going to just use the paging/chime function of NAX/Home, I would think all you would need would be a contact closure input to the processor. That could be a simple push-button of your
By MQSACK · #256514 ·
Re: Verizon Fios 4100 series, IP control???
My stb's have been upgraded probably 4 times since I signed on with Verizon.? I used the original remote to collect the IR codes and everything has worked fine through all the upgrades until the
By stefuel2 · #256513 ·
Re: Verizon Fios 4100 series, IP control???
Agreed. I've also had good luck with control. the files section has this IR Driver that I've been using: /g/crestron/files/IR%20Drivers/Verizon%20P265.ir I have had some issues with
By ckangis · #256512 ·
Re: Tracking active lobe in Shure MXA910 and MXA920
The mic will tell you when the different lobes gate on/off. MXA910 Response: < REP x AUTOMIX_GATE_OUT_EXT_SIG ON > < REP x AUTOMIX_GATE_OUT_EXT_SIG OFF > Where x is the corresponding lobe. You will
By Chris · #256511 ·
Re: SIMPL Module Input Signals
Yes but the thing is that if you place the simpl+ module inside the Simpl module, the signals will always be defined (from argument definition), right?
By kpapadopoulos · #256510 ·
Re: Verizon Fios 4100 series, IP control???
Nothing available. Although I will say I naver have issues with any Fios box on IR
By @johnmax · #256509 ·
Re: CrestronConsole.Printline #programming #simplsharp
I realised that I was running into the issue of console comments not always showing up in debugger in toolbox. ? My methods were printing to a remote console via ssh just fine. it¡¯s so weird how
By gbnet.hifi@... · #256508 ·
Verizon Fios 4100 series, IP control???
I have both VMS and IPC 4100's and they do respond to IR but occasionally flakey.? Is there protocol available to control them via IP?
By stefuel2 · #256507 ·
Re: HR-310s battery corrosion
We had an issue with HR-310s draining batteries about 3 years ago before Crestron came up with a firmware update for the HR-310 that corrected the issue.? So I would make sure that you have the
By Steve Kuehn · #256506 ·
Re: Intercom recommendations - Not 2N or Doorbird
I didn't know they were providing solutions for 2N now, but that's awesome. I've been using their custom plates and gadgets since the 90s, back when they were called HoloSound (not Vision). ?
By Tony Golden · #256505 ·
Re: SIMPL Module Input Signals
No, but you can do that in SIMPL+ using IsSignalDefined(). [email protected]> wrote:
By Jeremy Weatherford · #256504 ·
Tracking active lobe in Shure MXA910 and MXA920
I searched this forum and couldn't find any info; forgive me if I missed it. We have used audio levels to trigger camera presets many times. Of course, discreet mics work pretty well for this, ceiling
Doorbell C4 Chime Integrate or replace? Crestron Home
I am in the process of replacing some older Control 4 systems with Crestron Home using the CP4-R processsor and other goodies as required. One stumbling block is a few of these clients have the
By David Schulz · #256502 ·
SIMPL Module Input Signals
Is there any way inside a SIMPL module to know if any of it's input signals are connected in the root program? For example I have a module with 10 input signals and 10 output feedback signals. I want
By CDUB340 · #256501 ·
Re: Intercom recommendations - Not 2N or Doorbird
JEFFO is the man - Love getting his early morning callbacks ;-) Just ordered two 2N pieces from him....
By MQSACK · #256500 ·
CrestronConsole.Printline #programming #simplsharp
I have a weird situation where one method in a simpl# module won¡¯t write to the console. for argument sake. Public string test() { CrestronConsole.PrintLine(¡°Hello World¡±); Return (¡°Success");
Re: TCL display IP control
There is a CCD for controlling certain TCL TVs that is available for download from drivers.crestron.io: https://drivers.crestron.io/rad/driver-search/5678%3Fmodel%3D10671 There is help file embedded
By Chris Ma · #256498 ·
Re: Intercom recommendations - Not 2N or Doorbird
Also FYI, I just confirmed with the infamous JEFFO (Love that guy!)...:)? That the VIO product is no longer available...
By ckangis · #256497 ·