CEC to Samsung displays via AM3200?
All, I cannot get CEC to work with any of the samsung displays here on site. They are mix of Signage and OFE consumer units. None of them work, always get '@E' as reply no matter what I send or what
By
Tray Schaeffer
·
#253770
·
|
Re: IR receiver to IR transmitter with DM-NVX
Yes, there is IR ports on the DM-NVX transmitter, but my problem is to grab the IR signals from the cable box remote at the NVX receiver and send them in real time to the NVX transmitter.
By
Olivier Royer
·
#253769
·
|
MPC3-102 AVF with HD-CTL-101
Can anyone tell me how (or even if) the power commands are managed to a display, when a HD-CTL-101 is added to the IP Table of a MPC3-102 in AVF? I have all the gear on my test bench except for the
By
adks1010
·
#253768
·
|
Re: IR receiver to IR transmitter with DM-NVX
Do you not have a processor or NVX transmitter at the remote end? You should have IR ports there.
By
@johnmax
·
#253767
·
|
Re: Reavon UBR-X110 IP Control
Hi, Could you share the Reavon X100 driver also with me? Thanks in advance, Eduards
By
eduards.kazakovs@...
·
#253766
·
|
Re: DM-NAX-8ZSA unbalanced output
Hi, The analog outputs 1-2-3-4 will always correspond to zones 1-2-3-4 in any situation. There is no special programming needed. Though, if you want it to be a pure line-level output instead of
By
Hadley
·
#253765
·
|
DM-NAX-8ZSA unbalanced output
Hello all, Does anyone have use the 1-2 3-4 analog outputs on this amplifier? Is it works like the unbalanced output of the C2N-AMP 6x100? I don't see any instructions to activate them. Thanks. Angel
By
Angel Marti
·
#253764
·
|
Re: Running SIMPL debugger continuously
You totally could do it exactly as you propose for debug purposes, especially if it's just for inspecting variables in real time and you don't care about packet loss. For me, I'm actually driving
By
Michael Caldwell-Waller
·
#253763
·
|
IR receiver to IR transmitter with DM-NVX
Hello. Is there an easy way to have an IR receiver on the display side and an IR transmitter on the source side? Example, a customer wants to control a remote cable box from the display side. I was
By
Olivier Royer
·
#253762
·
|
Re: DSC PowerSeries Neo
It was on a system tested March of last year, the zone status was working. The driver at the time was HS2064_3.0000.0005IP from what I see in the program we tested. I have a co-worker who rolled out a
By
@ISC
·
#253761
·
|
Re: Running SIMPL debugger continuously
Fair point, MQTT is fairly complex and it would be hard to write by hand without a library. The more I think about operationalizing this at scale, I'm not sure if MQTT is a good fit for my situation.
By
Elliott Balsley
·
#253760
·
|
Re: DSP parametric EQ control
#programming
#values
I think you¡¯re looking for analog logic symbol called ¡°log with limits¡±. I haven¡¯t poked at the maths for it, but frequencies are a logarithmic scale. You may have to poke at the numbers a bit
By
Hood, Steven
·
#253759
·
|
DSP parametric EQ control
#programming
#values
Hi All, I'm seeking a way to control a filter's frequency in a parametric EQ block in Biamp. I have successfully achieved control of it in a linear sense, but the problem is that the frequency range
By
D_a_n_e
·
#253758
·
|
Using CP3-R relay and I/O resources in Pyng/OS2 programming
Hello, all.? I'm a first-time poster here, but a long-time SIMPL programmer and a relatively inexperienced Crestron Homer. Is there a way to pair CP3-R relays and/or I-O ports in an OS2 Pyng program,
By
Don Drolet
·
#253757
·
|
Roku <> Crestron Home
Has anyone found a good driver that provides full control of the roku on crestron home? Calling up directly to the apps and sending the remote's preset 1 and 2.
By
Mark
·
#253756
·
|
Is there a way to change the X-Frame:SAMEORIGIN setting on a processor hosted Xpanel that was created using Construct?
I want to embed the xpanel into another web page but this setting does not allow it. i have looked everywhere for the header setting but cannot find it so i am wondering if it is a processor level
By
brian@...
·
#253755
·
|
Re: Crestron Home Touch - Panels disconnection
The configuration is the following : All the TSW570P-R use a fixed IP address, like the processor (CP4-R) I Confirm that the Gateay is pingable Here is the configuration of the touchpanels : TSW-570PR
By
@CHP2
·
#253754
·
|
Re: Running SIMPL debugger continuously
Awesome, thank you for trying it and sharing your experience with the group ¡ª I really like Python. I also really like Crestron gear. Both do something specific really well and I¡¯ve gotten lots of
By
Michael Caldwell-Waller
·
#253753
·
|
Re: Running SIMPL debugger continuously
Thanks everyone, for the ideas. Michael, that MQTT module is very cool! I tested it and it works as advertised. Great for temporary debugging with MQTT Explorer. Have you thought about building the
By
Elliott Balsley
·
#253752
·
|
Re: DSC PowerSeries Neo
I'm aware of the Zone Status driver, but it didn't work. I also checked the notes in the dat file which state it's not supported. Did you use it with a Neo panel? They updated the Neo driver last year
By
Tony Golden
·