Re: Crestron Debugger Disconnection Issues
yeah, same issue.? ?Today was especially bad as I was working with a PRO4.? I have the same issue with MC4 in my office.
By
Rick Arnold
·
#251757
·
|
Re: Test Submission
I submitted mine in early October, got told 60-90 days, and have not heard back yet. A guy I know on the inside told me he'd be surprised if they got back to me before the end of the year, right now.
By
Gas Bandit
·
#251756
·
|
Re: Crestron Debugger Disconnection Issues
Oh yeah!...;(? esp. with 4-series for me...
By
ckangis
·
#251755
·
|
Master's 2024 Registration
Has anyone else had difficulty registering for Master's? I can click on the different classes, I get a descriptive popup, but I have no way to add the class that I can see.
By
Bill Kreider
·
#251754
·
|
VS2008 debug error with 3-series
After selecting the splusmanagerapp.exe and pressing attach, I get the following message: "Unable to attach to this process. Attach is not enabled for this process with this debug type." This has
By
rockyoucvs
·
#251753
·
|
Re: Test Submission
Email after submitting said 60-90 days. I received grade in about 2 weeks
By
monticellog@...
·
#251752
·
|
Test Submission
Hi All, For those that submitted their Silver, Gold, etc tests in the past, how long did it take to hear back from the evaluators with any feedback? Just curious. Thanks
By
Crestron_Programmer
·
#251751
·
|
Crestron Debugger Disconnection Issues
Has anyone had any issues with debugger contently disconnecting all the time?
By
Rick Arnold
·
#251750
·
|
Re: Crestron CCD and Samsung BET-H Series Issue
Update: I was able to get it working. I missed reading the part in OLH 1000527 ( https://community.crestron.com/s/article/id-1000527 ) that said "Don't rename the package file" so after changing the
By
Aaron Baker
·
#251749
·
|
Re: Crestron CCD and Samsung BET-H Series Issue
Here's a previous discussion on this. Hope it helps. /g/crestron/topic/76459057#249856
By
David Ives
·
#251748
·
|
Re: Any suggestion Swamp24x8 replacement with CrestronHome
Dont realy do much Home, but we use AudioControl M series amps in our Simpl systems. Not as many inputs as a Swamp but work just fine.
By
@johnmax
·
#251746
·
|
Re: GE Interlogix NX-8E NX-584 Zone transition message issues - Did I really find the fix?
I posted the source code I wrote up on GitHub and called it "NX-8E-ComFix" https://github.com/chipguyhere/NX-8E-ComFix Interested in feedback, accolades, whatever!? Hope this helps
By
Michael Caldwell-Waller
·
#251745
·
|
Re: GE Interlogix NX-8E NX-584 Zone transition message issues - Did I really find the fix?
Excellent Idea... I tried it.? The NX just wasn't having it.? It wouldn't accept a command that was immediately preceded by a filler ACK message, except on a small percentage of occasions (whether
By
Michael Caldwell-Waller
·
#251744
·
|
Re: GE Interlogix NX-8E NX-584 Zone transition message issues - Did I really find the fix?
I just checked and sure enough on the projects I used the NX8 I am using the poll. I am wondering if this issue is caused by not sending the ack, you you couldn't just add the ack to the beginning of
By
Eric Luckart
·
#251743
·
|
Re: GE Interlogix NX-8E NX-584 Zone transition message issues - Did I really find the fix?
Best I can tell it is a board that other people say they try that implements this protocol as a separate board. I am also only using the NX-8E serial port for testing this, and do not use the 584. If
By
Michael Caldwell-Waller
·
#251742
·
|
Re: GE Interlogix NX-8E NX-584 Zone transition message issues - Did I really find the fix?
What is the NX-584? I ask because I have only connected directly the onboard serial port, I have not noticed the issue you are talking about.
By
Eric Luckart
·
#251741
·
|
Re: Crestron CCD and Samsung BET-H Series Issue
Samsung BET series does not work with CCD. Could not get 232 to work either. The protocol is protected by NDA. Samsung never responded to the NDA request. Ended up setting the display to power on/off
By
Tray Schaeffer
·
#251740
·
|
GE Interlogix NX-8E NX-584 Zone transition message issues - Did I really find the fix?
Hi everyone -- I think I might have solved a decade old problem by accident... the issue as to why this GE Interlogix security system starts crapping out on its serial comms if you enable
By
Michael Caldwell-Waller
·
#251739
·
|
Re: Scheduler for Christmas Lights
A trick I have learned is that if you try to edit an event on the calendar, and then save, if you have accidentally put the scheduler.dat file in the wrong folder it will write a blank one and then
By
Robert Ray
·
#251738
·
|
Re: Scheduler for Christmas Lights
Assuming everything else is right, I believe the dat file should go in the NVRAM folder for the program slot not the root folder.
By
Matt Jones
·
#251737
·
|