Re: Postman to SIMPL
JPCH, You have the content a bit wrong, with the example he posted it should be: POST /axis-cgi/apidiscovery.cgi HTTP/1.1\nContent-Type: application/json\nUser-Agent: PostmanRuntime/7.34.0\nAccept:
By
Eric Luckart
·
#251469
·
|
Re: Postman to SIMPL
Simpl doesn't support multi-line, so you have to flatten the message down to one line. However HTTP messages MUST be multi-line to be valid syntax. So in Simpl you add a \n for each line. Like so:
By
JPCH
·
#251468
·
|
Postman to SIMPL
Hi guys. So I'm working with the VAPIX API, and I can get commands to work from postman, but I can't figure out how to format the working commands down to a string I can send out via a TCP client. How
By
Jim Germany
·
#251467
·
|
Re: Activity Detection module for TSW-x70
Thanks, I'm gonna try that in the future, I never noticed it, I always stopped at "activity detection"? :-D I understand Activity Detection responds to any change on the TP including page flips and
By
Olivier Royer
·
#251466
·
|
Re: Activity Detection module for TSW-x70
Yup, this got me too a few months ago. Use "Touch Detection" instead. I think Activity Detection means anything that happened to the panel like page flip, analog or digital change.
By
Crestron_Programmer
·
#251465
·
|
Activity Detection module for TSW-x70
Hello. I have a strange behaviour with a bunch of TSW-570P panels, after a customer complaint I noticed that the activity detection module was alway "1" and as soon as I hide a subpage, it momentarily
By
Olivier Royer
·
#251464
·
Edited
|
Re: DaVinci Fireplace control
We have done those fireplaces. They have to be polled for any feedback and commands it returns are similar to you have to add some extra logic to parch the retunes based on what you just told it to
By
j5races
·
#251463
·
|
Re: DaVinci Fireplace control
We had a job a couple years ago with 3 of these. Two of them worked fine from our end, but one of them didnt respond correctly and give proper feedback. After dealing with DaVinci they told us there
By
@johnmax
·
#251462
·
Edited
|
Re: PAC2 Relay programming
It is under other device. Right click the room you want it in. Select New, Device. Under that Manufacture:[Generic], Type:[All Types] Model:Generic relay-controlled device. Then select One LOW-Voltage
By
Eric Luckart
·
#251461
·
|
PAC2 Relay programming
Hi All, This is I'm sure its stupidly simple but I'm missing it, since I've never used the PAC2 internal relays before... *In D3,* I need to have an internal relay turn on 10s after processor boot up.
By
ckangis
·
#251460
·
Edited
|
Re: new phone - settings not moved with app
You can text or email them to yourself then import them in. It does not copy passwords. You click on the setting cog then export. On new device you use "open with" and search for Crestron Go.
By
Eric Luckart
·
#251459
·
|
Re: DaVinci Fireplace control
Thanks very much for responding. We do have the shifter in between already with the same results. -- Sincerely, Craig S. Abitz President Installation Specialties, Inc. 9 Albertson Ave., Suite 4
By
Craig Abitz
·
#251458
·
|
new phone - settings not moved with app
is there any way a client can move the settings over for Crestron App/Go when buying a new phone?
By
mark kaye
·
#251457
·
|
Re: DaVinci Fireplace control
Hi Craig, it seems that the DaVinci uses TTL, Crestron RS232. You need to add a TTL to RS232 shifter inbetween for correct operation. Give google a chance for such a shifter, should be just a few
By
crestronfreak55
·
#251456
·
|
DaVinci Fireplace control
Hello, Has anyone been able to integrate a SIMPL program with a DaVinci Fireplace? We have followed the limited instructions, have the recommended adapters and it works with the native DaVinci glass
By
Craig Abitz
·
#251455
·
|
Re: Lessons Learned - Crestron EISC
#simplwindows
#useful
#EISC
It let's me edit my posts
By
Eric Luckart
·
#251454
·
|
Re: Slave CP3 of RMC3
https://community.crestron.com/s/article/id-5232
By
Dave H - Crestron True Blue Tech Support Engineer Since 2014
·
#251453
·
|
Re: Lessons Learned - Crestron EISC
#simplwindows
#useful
#EISC
The links to help.crestron.com are links that describe what I am doing with the F6 command. Just in case the text version that precedes it is unclear with the brackets and all. That is all, just
By
Duck 1776
·
#251452
·
|
Re: D3 Delete Gateway?
That is the best place to move wireless devices from one gateway to a different one.
By
Eric Luckart
·
#251451
·
|
Re: D3 Delete Gateway?
Boy they hid that good, thank you.
By
Gary Miller
·
#251450
·
|