Re: PAC2M available
Austin TX
By galcala · #250428 ·
Re: DSC Neo Integration issues
We have worked with many different panels over the years, and the general findings vary greatly on functionality, particularly on the sector the alarm panel has been created/intended from (ie bank
By programmers@... · #250427 ·
Re: Shelly button press
ah, I see. I need to set Shelly I/O URL Actions. All set.
Re: Shelly button press
Jay @jbasen , I'm running v23.1 (Dimmer v6) with a Shelly Wall Dimmer and I receive no feedback from button presses (nor local brightness which I think I understand is a limitation of Shelly). I've
Re: CP3 Ethernet Issues
I've been battling this issue intermittently with a site for the last few months also... After a CP3 reboot, things are stable for some period of time (sometimes for months), then the system will
By ckangis · #250424 ·
Re: Add Toggle Dim function to C2N-CB-TS keypad buttons in SIMPL
Thanks, that's the one I was looking for. I now remember using it some years back and just forgot. Years back when I was only programming Crestron, I always said that knowing all the "tools" you have
By Etienne · #250423 ·
Re: Add Toggle Dim function to C2N-CB-TS keypad buttons in SIMPL
I actually did this yesterday and it created a ton of SIMPL programming. I know I can strip it down to only what I need, but wow!
By Etienne · #250422 ·
Re: DSC Neo Integration issues
I was just hoping they had. I have a client that had an advent system that died. The security guy replaced it with 2 Elk systems. One for security the other for environmental. I get complaints every
By Eric Luckart · #250421 ·
Re: PAC2M available
Where is it located? NFH
By nicofreda · #250420 ·
Re: DSC Neo Integration issues
I don't believe the Elk modules have changed in many years.? So, they don't support full keypad emulation.? That being said, I have always found that they support the basic functions a homeowner
By jbasen · #250419 ·
PAC2M available
I removed a unit from a resi project.? It works. If anyone can use it - make me a reasonable offer and I'll send it your way...
By galcala · #250418 ·
Re: DSC Neo Integration issues
Jay, Has the Elk protocol ever been expanded for keypad emulation?
By Eric Luckart · #250417 ·
Re: DSC Neo Integration issues
I¡¯ve always liked the Elk alarm panels. Very good integration and the protocol documentation is available from Elk. So, if the integration modules don¡¯t include a feature you need you can add it
By jbasen · #250416 ·
Re: DSC Neo Integration issues
My default go-to is the Honeywell Vista 128BTP. I don't know if there's integration with Alarm.com (except for monitoring)... I'm sure others will have add'l suggestions
By ckangis · #250415 ·
Re: DSC Neo Integration issues
Well that sucks! So what alarm brand is everyone using that is compatible with alarm.com and Simpl programable? This house was not wired for alarm keypads and the homeowner was promised that he could
By thumpu77@... · #250414 ·
Re: Add Toggle Dim function to C2N-CB-TS keypad buttons in SIMPL
Of the top of my head I would probably use the press hold module, a toggle, 2 and's and a ramp. The hold would trigger the toggle and the 2 and's. One output of the toggle would go to one and, and the
By Eric Luckart · #250413 ·
Re: Add Toggle Dim function to C2N-CB-TS keypad buttons in SIMPL
I have done this a long time ago, I don't remember the exact logic I used. But I do know that I created a D3 project that was just one light and one press, compiled and opened the Simpl and reversed
By Gary Miller · #250412 ·
Re: Add Toggle Dim function to C2N-CB-TS keypad buttons in SIMPL
Take a look at the Crestron Module: press and hold v1.2 (cm) It will give you a separate 'Not Held' and 'Held' outputs that you can take separately from your button press to your toggle logic and
By ckangis · #250411 ·
Add Toggle Dim function to C2N-CB-TS keypad buttons in SIMPL
Hi, I have a new request from a old project to add Toggle Dim to some of the keypad buttons. This project was completed some years ago and we programmed the buttons to only Toggle the light(s) on/off
By Etienne · #250410 ·
Re: DSC Neo Integration issues
You might start with reviewing this previous thread...Unless things have changed recently, you may continue to be disappointed... /g/crestron/topic/94194951#249715
By ckangis · #250409 ·