Re: New BSS Modules (3-series)
scottcoumbe, with regards to the toggle, this sounds more like a bss issue vs a module issue.
By
jeff
·
#219220
·
|
Re: Crestron DM System - Detecting a DM transmitter by IPID
The IPID is reassigned by the frame when it is connected, based on what the program tells it it should be. Whatever is plugged into input #4 will always get the same IPID. Crestron@...>
By
Phil Bridges
·
#219219
·
|
Re: Samsung TVs IR control discrete power on doesn't work after being off a long time
Might be same or similar problem. I had a samsung the other day not take on or off codes from the IR receiver on the bottom edge of the tv. Volume, mute etc all worked perfectly, but nothing for power
By
saul
·
#219217
·
|
Re: Crestron DM System - Detecting a DM transmitter by IPID
brilliant Andrew that does does give me something have a go at. Will be diving into that first thing tomorrow, cheers for the assist its very much appreciated.
By
Shavon Taylor
·
#219216
·
|
Re: MMS-2 power supply
Thanks, Pat. [Crestron] <Crestron@...> wrote:
By
Phil Bridges
·
#219218
·
|
Re: New BSS Modules (3-series)
The WAIT(30) is inside the SIMPL+ Wrapper of the Level module. Comment it out as a test?
By
jeff
·
#219215
·
|
Re: Crestron DM System - Detecting a DM transmitter by IPID
to do the latter and simply know that any transmitter is connected. once i drop a transmitter on the dm input card will it make any difference that the code has one IPID showing the unit is fixed and
By
Shavon Taylor
·
#219214
·
|
Re: MMS-2 power supply
If you have a 19.5v power supply from a Dell computer then you can also use that. I doubt that out when inhale a clients MMS crap out and put my Dell power supply in its place while waiting for a
By
Pat Molettieri
·
#219213
·
|
Re: Crestron DM System - Detecting a DM transmitter by IPID
That doesn't seem foolproof to me...they shouldn't need to care which TX is plugged into the floor box. Give them one button on the UI that says Floor Box or Laptop or whatever is appropriate, then
By
Andrew Welker <andrew.welker@...>
·
#219212
·
|
Re: Crestron DM System - Detecting a DM transmitter by IPID
cheers for that, seems to be the general consensus to rcon the dm frame i shall have to give that a go.
By
Shavon Taylor
·
#219211
·
|
Re: Crestron DM System - Detecting a DM transmitter by IPID
absolutely for the latter the extender does the job. but yes im going for the former, i want to know which of a set of 4 transmitters is connected to say input 4. im trying to dummy proof it for the
By
Shavon Taylor
·
#219210
·
|
Sony Blu-ray IP control
Sony Bluray IP control, Has any one written anything for this yet? I know it is possible, but i cant find anything written already. Its a little beyond my capabilities to write my self. Thanks Saul
By
saul
·
#219209
·
|
Re: Crestron DM System - Detecting a DM transmitter by IPID
You want to know *which* particular transmitter is plugged into, for example, input 4? Or you want to know that any transmitter is plugged into input 4? For the latter, the offline extender gets you
By
Phil Bridges
·
#219208
·
|
Re: Crestron DM System - Detecting a DM transmitter by IPID
So, if I'm understanding you, there's a TX that moves around the room with a specific source and they get moved to different inputs on the switcher. So in PNM the ipaddress of the TX box is a known
By
Justin Hill
·
#219207
·
|
Re: Crestron DM System - Detecting a DM transmitter by IPID
First thought I had is if you see a roombox come online, have the processor connect to the DM frame, then rcon the mac of the roombox that came online. That could be slightly problematic since when a
By
Caleb Radecky
·
#219206
·
|
Re: Crestron DM System - Detecting a DM transmitter by IPID
ahh i believe i see what your saying and how that could work, i think, not 100% sure i see all the way but i'll look some more on it. if i see correctly i need to explain the scenario fully. If one
By
Shavon Taylor
·
#219205
·
|
Re: Crestron DM System - Detecting a DM transmitter by IPID
Right, im currently doing that but it only detects that the unit is online. i want to be able to know what input it has been connected to so that no matter if i gets connected to dm input card 7 or 5
By
Shavon Taylor
·
#219204
·
|
Re: Latest version of Samsung EXlink protocol
this is the module I have been using for the last few years that works fine. it has to see actual 2 way communication and you have to start with the tv off and turn it on with the module. Samsung
By
saul
·
#219203
·
|
Re: Crestron DM System - Detecting a DM transmitter by IPID
I'm unaware of a way to get that through the DM. If you have other network equipment that is always moving with the transmitter, but isn't going through the DM, you may be able to poll the switch for
By
BruteForceIsUnderRated
·
#219201
·
|
Re: Crestron DM System - Detecting a DM transmitter by IPID
Sure it does. Send the offline to a not, then the output of the not to the input on an init. Send the output of the init to the appropriate video out on the DM switch. Crestron@...> wrote:
By
Andrew Welker <andrew.welker@...>
·
#219202
·
|