¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date
Ipad pro
Anyone has tried ipad pro running crestron app, whats your feedback? Do you use same cres app in vtpro as the ipad? Is the screen space enough to show floor plans of house?
By wes_lim88@... · #210908 ·
Re: VT Pro Access Denied
Yes, Dropbox does the same for me, If I leave it running when VTPro or D3 is Running. As long as you keep it paused with either of those two programs, you're fine. Simpl never gives it an issue. I
By stainbow1@... · #210906 ·
Re: VT Pro Access Denied
Try reverting to VT Pro-e? 6 v6.0.01.13 It fixed the issue for me. No more access denied message.
By ivanalejo1@... · #210905 ·
Re: VT Pro Access Denied
I figured out the problem since I do not work out of Dropbox or any cloud storage due to all the issues mentioned above. Only a few people I talked to had this issue, but it was due to the recent
By ivanalejo1@... · #210907 ·
Re: VT Pro Access Denied
Crestron told me it had something to do with the Dropbox file structure, something like that.
By keith.gossen · #210904 ·
Re: VT Pro Access Denied
I used to get this repeatedly, and of course it always followed my doing something intensive and just before an autosave happened...! I narrowed it down to a problem with running the file from a
By nick_masterson_uk · #210903 ·
Re: Simpl+ parsing clean up/optimization
To be clear, threadsafe does work for 2-series as well, even though the documentation doesn't say that. Crestron@...> wrote:
By Andrew Welker <andrew.welker@...> · #210902 ·
Re: Simpl+ parsing clean up/optimization
As Andrew suggested, if you're compiling for 3-series use THREADSAFE CHANGE. This will prevent multiple instances of the same event from occurring simultaneously (one one thread can run, all other
By fredv@... · #210901 ·
Re: Crestron thermostat alternative?
i'm interested pls send email markkaye (at) avfusion.ca mark
By mark kaye · #210900 ·
Re: Simpl+ parsing clean up/optimization
I would suggest using the while(1)/gather structure in a change event for the string. Make sure to put a threadsafe keyword on the event. The threadsafe will keep the module from spinning up a new
By Andrew Welker <andrew.welker@...> · #210899 ·
Re: Simpl+ parsing clean up/optimization
Simpl# can help. 30 §Á§ß§Ó 2016 §Ô. 13:07 §á§à§Ý§î§Ù§à§Ó§Ñ§ä§Ö§Ý§î "jcwieser@... [Crestron]" < Crestron@...> §ß§Ñ§á§Ú§ã§Ñ§Ý:
By Roman <roman.marinenko@...> · #210898 ·
Simpl+ parsing clean up/optimization
I have learned a lot from searching old topics. however, I could use some direction on how to clean up/optimize simpl+ parsing. I have module to control a LifeSize Icon 800 over rs232 that is working
By jcwieser · #210897 ·
Re: Crestron Connected and Denon x4200w
Wondering a firmware issue perhaps. Initially a power cycle worked. Now finding need to remove cord and soft reset. We just added static ip and wake on lan. Theater connected but family room didn't.
By Andy Wasserman · #210896 ·
Re: Crestron Connected and Denon x4200w
How long are you waiting after an upload? We found if we waited 10 minutes it would connect again. If we were in a hurry we'd just manually power up the AVR and power down again. Pain in butt. Never
By keith.gossen · #210895 ·
Re: VT Pro Access Denied
I get this also but it¡¯s a bit worse for me. The output file is generated but the source VTP is deleted while open. Very annoying. Only happens a couple of times per week so I can recover... Tray
By Tray · #210894 ·
Crestron Connected and Denon x4200w
Having some issues here. Works great when in sync but every time a power surge or outage, or update to Crestron loaded, denon's do not automatically reconnect to Crestron. A power cycle doe not help
By Andy Wasserman · #210893 ·
Re: VT Pro Access Denied
I get that due to OneDrive every once in a while, sometimes with no warning or error. On a compile I end up with a good .vtz and a .vtp that didn't update. I have auto save enabled, so worst case my
By logantv · #210892 ·
Re: Auto Shutdown with Alarm Clock v2.0
If you are talking about the "Alarm Clock v2.0" module in the database then the problem is that the "day" inputs act as toggles. If you know how to edit S+ then that would be the best way to make it
By Steve McNally · #210891 ·
Re: Auto Shutdown with Alarm Clock v2.0
Try the Crestron eventsked module (I think it's on v3) instead. You can set it to run on specific days of the week or all of them.
By Hope Roth · #210890 ·
Re: Auto Shutdown with Alarm Clock v2.0
I just played with a little more. You have to set the specific day. I'm just going to have it do that way where that have to say Monday at 20:25. When the alarm sounds, a page comes up giving them the
By Billy Silar · #210889 ·