Re: LG OLED TV CCD IP Driver - How to get it to work on a CP3?
Below are notes I send to technicians, with the settings needed for LG ethernet communications. You've obviously taken care of #1, but I'd double-check the others. Typically when Power On (only)
By
Tony Golden
·
#251675
·
|
Re: Best way to program for a back up processor
This is probably too simple, but why not include the network and power cable in the cable routine? If you are moving some cables from one to the other, what difference does it make if you move a
By
MSTC
·
#251674
·
|
Re: Best way to program for a back up processor
Maybe programatically disconnect the TCP/IP clients from the secondary processor when the primary processor is detected as "ONLINE", and drive the secondary TCP/IP connection states high when the
By
Rob
·
#251673
·
|
Re: LG OLED TV CCD IP Driver - How to get it to work on a CP3?
Hi Joachim, thanks for the information. I was hoping not to have to dive into the details of the API of the TVs as there?s a driver available. I think i?ll go for the WoL for the power-on and then
By
Thorsten K?hler
·
#251672
·
|
Re: Best way to program for a back up processor
Thanks for the recommendation. I¡¯ll do some testing on that.
By
Audvizer
·
#251671
·
|
Re: LG OLED TV CCD IP Driver - How to get it to work on a CP3?
Hello Thorsten, do you have the API/Command-Specs for this device? If yes, you can do following: rename the pkg into a zip-file, unzip it. Inside there is the dll. Use a de-compiler, like JetBrains
By
Joachim Hornung
·
#251670
·
|
Re: LG OLED TV CCD IP Driver - How to get it to work on a CP3?
OK, will do that, thanks. Cheers, Thorsten -----Urspr¨¹ngliche Nachricht----- Von: [email protected] <[email protected]> Im Auftrag von rickwookie Gesendet: Donnerstag, 16. November 2023 14:01 An:
By
Thorsten K?hler
·
#251669
·
|
Re: LG OLED TV CCD IP Driver - How to get it to work on a CP3?
I found the Power On would work about 10% of the time (as in 1 in 20 triggers). Send a simple WoL packet to the TVs MAC address (use the UDP symbol) and it fires every time. It annoys me that the CCD
By
rickwookie
·
#251668
·
|
Re: LG OLED TV CCD IP Driver - How to get it to work on a CP3?
Update: I changed the order of the passcode and MAC-address, and now control works partially. I only need power on/off, input switching and power feedback. That works, except power-on and power
By
Thorsten K?hler
·
#251667
·
|
Re: Best way to program for a back up processor
What I have done several times is to have both processors have the exact same IP, program(s) and settings, then they just move over the Ethernet cable along with the RS-232 and relay connections. Just
By
Charles Jones
·
#251666
·
|
Best way to program for a back up processor
Hi All, I have a UC Engine with room environment controls and lots of Teams Automation. The client wants a back up CP4 to take over if the primary CP4 goes down for whatever reason. I have 3 coms,
By
Audvizer
·
#251665
·
|
Re: LG OLED TV CCD IP Driver - How to get it to work on a CP3?
Thanks, Tony. Enabling logging revealed the following messages: ?00:02:52.344: [Console Data] : 048-12:05:26.696 ( 3) [Info ] CORD - LG Smart TV : Processing control command Connection.Connect()
By
Thorsten K?hler
·
#251664
·
|
Re: EISC from one Pro4 to many CP4N's with the same IPID
I forgot to mention, we have about 50 spaces, each with CP4N, and I'm working on getting all of them on the exact same program that I'll be able to mass load. Plus, the head-end Pro4 manages all the
By
Charles Jones
·
#251663
·
|
Re: EISC from one Pro4 to many CP4N's with the same IPID
Ha ha MSTC. I fixed it. I meant per processor, auto correct changed it...
By
Eric Luckart
·
#251662
·
|
Topics in Home Automation - New Article in Residential Tech Today
My latest article, "Circular Introduces Next-Gen Smart Ring Slim¡± is being published by the good folks at Residential Tech Today Magazine on their web site. Circular, a French technology company,
By
jbasen
·
#251661
·
|
Re: EISC from one Pro4 to many CP4N's with the same IPID
That sounds magical, what is it? ?On 11/15/23, 10:05 AM, "Eric Luckart" <[email protected] <mailto:[email protected]> on behalf of eluckart@... <mailto:eluckart@...>> wrote: EISC
By
MSTC
·
#251660
·
|
Re: EISC from one Pro4 to many CP4N's with the same IPID
What is the timing requirement for updating the remote processors?? Is this a thing that could be accomplished at some interval or does it need to be real time?? You can accomplish the transfer of
By
MSTC
·
#251659
·
|
Re: EISC from one Pro4 to many CP4N's with the same IPID
EISC is one to one not one to many. Why not just use an ipid per processor?
By
Eric Luckart
·
#251658
·
Edited
|
EISC from one Pro4 to many CP4N's with the same IPID
Hi All, I'm trying to get this working where my Pro4 has, for now, a bunch of channel labels that I want any of the 50+ CP4N's to access to update the buttons on the local touch panels in the rooms.
By
Charles Jones
·
#251657
·
|
Re: TS-770 How to go back to User Project after launching Sonos app
Cue Barbara Streisand singing 'Memories...' :)
By
ckangis
·
#251656
·
|