¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date

Re: Alpha America Sign Example

 

I also have worked extensively with this product and have a fairly good amount of "practical" information that I have extracted in short form from the documentation. I have written at least a couple of useful modules that provide a number of parameter based presets of various colors as well as dynamically editable presets of various colors. I can post some details if you are still in need.


Re: Q_SYS Crestron Certified Modules version 5.0 and 5.1 #cp4 #q-sys

 

Never digged too deep for this bug, I just put a buffer on all inputs within this module, and enable the buffer by the initial input from the core module, error gone.


Re: NAX - troubling streams #nax

 

Thanks for all the replies chaps,

The main AV CP3 sits on our service VLAN-4
The 5 Sonos players are on the user VLAN-3 and these are handled by a second CP3 on the user VLAN.

I've changed my logic slightly and now start the stream based on the following:
* Update status - sets an IL
* Valid Multicast address
* NAX is online (using offline manager device extender for each of the NAX units)
* Sonos CP3 online

So far I have not implemented setting the port.

The above hoop jumping seems to be favorable, however I'll hold off judgement until I've tested this some more.

@Eric Luckard
The IT guys have combed over the network and they are satisfied that it is up to task.
The management ports on the NAX's are on the user VLAN. The content ports are on a dedicated NVX/NAX VLAN.
No issues with NVX.

There are a total of 6 x DM-NAX-8ZSA on this site.
The 5 Sonos units are in the head end connected to the 2 DM-NAX-8ZSA that I mentioned previously and these need to be streamed to all the remote DM-NAX-8ZSA's.


Re: toggle problem

 

Hi Tony,

I'll need to look into why that email address bounced back as that email address should still be valid.? At this point, I think it makes sense to stop charging for the tool as interest in it has fallen off a cliff over the last several years.? I'll send you a download link for it at some point today.

Thanks,
Geoff


On Wed, Mar 15, 2023 at 7:07?AM <tony@...> wrote:
Hi Geoffrey,?

Are you still selling licenses for your IR tool? I tried reaching out on the email on your website but I got a bounce back.?


Re: toggle problem

 

Hi Geoffrey,?

Are you still selling licenses for your IR tool? I tried reaching out on the email on your website but I got a bounce back.?


Re: NAX - troubling streams #nax

 

¿ªÔÆÌåÓý

Hi Slip

We are currently working through a very similar issue with TB. Our current config has been stable for a couple of weeks now, with the biggest change being to set the IP config manually, FYI my tech was unable to do this using the Web UI so had to use text console.

We are also about to enable Auth on the NAX units today as we have also been experiencing a loss of control with Mediaplayer on the control system.

Good luck

Regards

Justyn

On 15 Mar 2023, at 03:37, Eric Luckart <eluckart@...> wrote:

?I have also stopped using the built in streaming. ?I didn't like how if someone was streaming something on stream 1 then zone 1 decided to airplay it would takeover that stream.

We have used Cisco CBS, Netgear 4300 & 4250's with our NAX's and I cant say I have had any issues with source sharing. ?On most of my projects access AES67 sources from both NVX's and other NAX's. ?I am wondering if it isn't something with your network.






Re: LG OLED97G29LA 97'' LG 4K OLED evo TV G2

 

¿ªÔÆÌåÓý

Hm, wouldn?t be the first time manufacturers? technical support doesn?t have a clue about the capabilities of their devices¡­

Unfortunately, I don?t have the device at hand, the client didn?t buy yet.

?

Cheers,

Thorsten

?

Von: [email protected] <[email protected]> Im Auftrag von David
Gesendet: Dienstag, 14. M?rz 2023 23:23
An: [email protected]
Betreff: Re: [crestron] LG OLED97G29LA 97'' LG 4K OLED evo TV G2

?

On Tue, Mar 14, 2023 at 08:39 AM, Thorsten K?hler wrote:

OK, just received feedback from LG technical support.

They say the OLED97G29LA doesn?t support IP control/external control as it is a consumer device. I shall look at the business model

?

However, the OLED97G2PUA you mentioned might be a good alternative ¨C if it?s available in EU.

?

Thanks,

Thorsten

?

Interesting, the LG C1 is also a consumer device...
If you already have this display and can thinker with it I'd recommend trying out this :

¡±To bring up IP Control configuration, first open up TV¡¯s Settings Menu. Keep the Network icon focused, then enter numerical key 828888 using TV¡¯s IR Remote¡±
This should bring the IP control hidden menu and you should be able to follow the CCD Guide to create the IP control. also there's another old post that can be helpful.
/g/crestron/topic/80639713


Re: DSC PowerSeries Neo

 

Tony, What did you figure out? Any keypad emulation or zone feedback?


Re: Console command for changing a CRESNET device Serial Number? #crestron

 

If you can figure out how to convert the sn# to a TSID you could use setppnbycresnetid


Re: SIMPL calendar function

 

In the files section. Chip has a Day of the week module that is all in simpl. I have used it a few times and it works well.


Re: Andriod TV control

 

What TV?


Re: NAX - troubling streams #nax

 

I have also stopped using the built in streaming. I didn't like how if someone was streaming something on stream 1 then zone 1 decided to airplay it would takeover that stream.

We have used Cisco CBS, Netgear 4300 & 4250's with our NAX's and I cant say I have had any issues with source sharing. On most of my projects access AES67 sources from both NVX's and other NAX's. I am wondering if it isn't something with your network.


Andriod TV control

 

Anyone can guide me to how to control an Andriod TV via IP (like using a remote control) through SIMPL??


Re: Logic Engine Error

 

I'm having similar error right now with two CP4N, loaded with different program.

I've been investigating it with Crestron Support for 2-month, the error only happened 3-time, all in same time slot - 10 min after program restart, while we have restarted program like million of times, it only happened 3-time. Required reboot of CP4N when it happened.

Notice: LogicEngine_1 # 2023-03-15 07:11:37 # WriteUnixDomainSocket: len=78 pid=9207; Thread 9223; timeout 32000; SO_SNDBUF 419600 (tick end 361892824: start 361858779: delta 34045) maxMsg 4196; sendto /dev/shm/rqueue/LOGIC__simpl_app01_TO_SPLUS_QUEUE/0009244 error Resource temporarily unavailable(11)
Error: LogicEngine_1 # 2023-03-15 07:11:37 # SplusIntfc: Send module send signal Msg to Splus failed. Msg Q error = 0xb. Size written is 4164:78 (timeout:32000)


Re: Error: LogicEngine_1...SplusIntfc: Send module send signal Msg to Splus failed... - any suggestions where to start

 

I'm having similar error right now with two CP4N, loaded with different program.

I've been investigating it with Crestron Support for 2-month, the error only happened 3-time, all in same time slot - 10 min after program restart, while we have restarted program like million of times, it only happened 3-time. Required reboot of CP4N when it happened.

Notice: LogicEngine_1 # 2023-03-15 07:11:37 # WriteUnixDomainSocket: len=78 pid=9207; Thread 9223; timeout 32000; SO_SNDBUF 419600 (tick end 361892824: start 361858779: delta 34045) maxMsg 4196; sendto /dev/shm/rqueue/LOGIC__simpl_app01_TO_SPLUS_QUEUE/0009244 error Resource temporarily unavailable(11)
Error: LogicEngine_1 # 2023-03-15 07:11:37 # SplusIntfc: Send module send signal Msg to Splus failed. Msg Q error = 0xb. Size written is 4164:78 (timeout:32000)


Re: Duplicating UI programming workflow in Simpl - Issues with CRPC Smart Graphics

 

Caught me out so often as I mainly do residential with multiple UI's

my steps are?

Duplicate UI Device Programing
Delete Folder for Second UI If already in the Program
Then Copy the UI Folder as well this way it keeps the Smart Graphics intact
F9 Rename Second device & Second Device Logic folder.
Delete the Auto Generated Smart Graphics Folder (A feature we could so do without)

Works for me hope it helps

Stu.


Re: Analog Newbie Question #simplwindows

 

Yes, has a customer call me because their electric screen was not coming down. I suggested they check the power before we investigate control. Sure enough, a contractor there for some other job had turned the power off and forgot to turn it back on. Easily done, we've all be there.

Also, if there is no plan to change the volumes except by control, there is really little reason to use the Feedback signal from the amp, just use the input signal for the gauge. This is will result in a snappier response for the users, especially when working with devices that may be slow to propagate changes to their "feedback" signal.


Re: LG OLED97G29LA 97'' LG 4K OLED evo TV G2

 

On Tue, Mar 14, 2023 at 08:39 AM, Thorsten K?hler wrote:

OK, just received feedback from LG technical support.

They say the OLED97G29LA doesn?t support IP control/external control as it is a consumer device. I shall look at the business model

?

However, the OLED97G2PUA you mentioned might be a good alternative ¨C if it?s available in EU.

?

Thanks,

Thorsten

?

Interesting, the LG C1 is also a consumer device...
If you already have this display and can thinker with it I'd recommend trying out this :

¡±To bring up IP Control configuration, first open up TV¡¯s Settings Menu. Keep the Network icon focused, then enter numerical key 828888 using TV¡¯s IR Remote¡±
This should bring the IP control hidden menu and you should be able to follow the CCD Guide to create the IP control. also there's another old post that can be helpful.
/g/crestron/topic/80639713


Re: NAX - troubling streams #nax

 

On Tue, Mar 14, 2023 at 04:57 PM, XSDS wrote:
kind of defeats the purpose of AES67
But even using Autonomic (or outboard Sonos players, etc.) this is still a very handy function - eliminates the gobs of loop-thru jumpers and allows for de-centralized units to share all the sources...

+1 for Autonomic now that they have the AMB to add Apple Music, etc. - and hopefully they're resolve the MMS HW failure issues that they've had in the past...

As an aside, I'm a fan of using multiple MMS-1e units (ex: one for each user), which among other benefits, eliminates the single-chassis failure issue. if you loose one, you still have the others to keep you going...


Re: Analog Newbie Question #simplwindows

 

On Tue, Mar 14, 2023 at 04:12 PM, Corbin Lovering wrote:
.. the IEC power cable was UNPLUGGED.?
Yeah, we've all had stuff like that happen!!...:)