Samsung MDC Module to configure videowall layout
#crestron
#samsung
Im Hoping someone has a Samsung video wall MDC module "LH55VMT" ?
By
richard@...
·
#244822
·
|
Samsung MDC Module to configure videowall layout
#crestron
Good day I Need to control a Samsung Video wall 3x2? "LH55VMT" I am hoping someone has a Module with commands such as "Power On/Off"? , as well as "video wall mode on/off" and Layouts for instance
By
richard@...
·
#244821
·
|
CNTBLOCK brain fart
I need enough power for 3 touch screens @ 27 watts each.? I believe the power supply in a Pro2 is 50 watts.? If I use a CNTBLOCK with the jumper removed, can I connect the Pro2 to net 1 and the
By
stefuel2
·
#244820
·
|
Crestron Shade Custom Option
Has anyone installed a CSM-QMTDC-163-1-EX motor with a 24V Lithium rechargeable battery pack in lieu of the normal 24V hard-wired power supply?? I understand that Crestron is now taking orders for
By
skdanser
·
#244819
·
|
Re: Crestron Q-SYS[Core] V5.0 - not staying connected
Also make sure the clock is master clock is synced properly I remember having issues similar to what your experiencing when the core 110 was not synced correctly wrote: Have a great day, and please
By
Gregory Davis
·
#244818
·
|
Re: Crestron Q-SYS[Core] V5.0 - not staying connected
Make sure you update all the modules. ?I barked at whomever would listen at the app market email for not versioning this properly. ?It's not just the CLZ. ?Then do a "recompile all" or Alt-F12.
By
Michael Block
·
#244817
·
|
Re: Simpl+ Analog_Input vs Long_Integer
If you need a value larger that 65535 in S+ you need to declare the variable as a Long_Integer. What you are seeing is the lower 16 bits of the value as the analog is automatically truncated. Be
By
l_codd
·
#244816
·
|
Simpl+ Analog_Input vs Long_Integer
I have a Simpl+ module that has an analog_input value representing volume level (0-65534) and storing that value and recalling that value on a reboot. This seems to work unless analog_input value is <
By
Brad Wykoff
·
#244815
·
|
Re: Using Event Scheduler 2 (v1.2) with 4-series
It's your program ID tag. So if your tag is AV for instance then: \\AV\\EventScheduling.dat
By
Slip Cougan
·
#244814
·
|
Re: ZeeVee Zyper 4K Management Platform.
@ josephtimmerman You just opened a Telnet socket to the ZV endpoint and sent this string to control projector? Just want to know in case I run into this again. Even ZV support could not get this to
By
Tray Schaeffer
·
#244813
·
Edited
|
Re: ZeeVee Zyper 4K Management Platform.
I got this to work using a simple SIO and TCP/IP connection on port 23. For hex commands you'll need an extra \. Example:?send DEC-PROJ-1 rs232 \\x02\\x00\\x00\\x00\\x00\\x02 \n used this to get an
By
josephtimmerman@...
·
#244812
·
|
Re: ZeeVee Zyper 4K Management Platform.
This is the S+ code snippet for code I used: FUNCTION SendCommand() { TEMP = Serial_TX;? //local copy of incoming data MAKESTRING(ZV_Device_TX, "switch %s server rs232\n", DecoderName ); DELAY
By
Tray Schaeffer
·
#244811
·
|
Re: ZeeVee Zyper 4K Management Platform.
Spent a few days on this and could never get it to work. Did direct IP to the display, instead. Try to send 232 commands from the Zyper management platform web page. Type text in the window, text is
By
Tray Schaeffer
·
#244810
·
|
Re: Using Event Scheduler 2 (v1.2) with 4-series
How do you know what the full filepath is? If I have the default program ID tag set in the header, would that be in \simpl\app01? So correct location of this file is
By
@giselmoe
·
#244809
·
|
Re: ZeeVee Zyper 4K Management Platform.
I've been looking into this as well. The supplied Help file for the encoder makes it sound very confusing... "RS232_Join - Setting this value will join the encoder's RS232 port to the decoder with the
By
theodore_e
·
#244808
·
|
Re: ZeeVee Zyper 4K Management Platform.
I am having issues controlling the display off the rs232 port of the zeevee decoder as well. Did you ever get this to work?
By
josephtimmerman@...
·
#244806
·
|
Re: Weather widget on xx52 touch panels
I had a case open with support for this exact issue and it never really got figured out. It would happen every few days where my location was set as default and it would un-default itself on its own.
By
@johnmax
·
#244805
·
|
Weather widget on xx52 touch panels
Hi, I have an odd issue with the weather widget grabbing a bogus area code and setting it as default. I have tried everything including hard coding it in the VT project and although it keeps the hard
By
Cassandra Coughlin
·
#244804
·
|
Re: Crestron Q-SYS[Core] V5.0 - not staying connected
Post a screenshot of your module and connection logic. Thank you Matt
By
Matt Zombolas
·
#244803
·
|
Re: Crestron Q-SYS[Core] V5.0 - not staying connected
Thanks Michael, I tried the updated module, no joy. Luca
By
Luca Urbinati
·
#244802
·
|