Re: Authorization for Connections
¿ªÔÆÌåÓýThis is one example of why I have the utmost respect for members of this group. Taking the time to document this issue and share it with the rest of us is very cool of you Brian!Ryan Cunningham? On Jun 14, 2021, at 12:35 PM, Brian Matson <bmatson@...> wrote:
|
Authorization for Connections
This is just a heads up to everyone.
I just got off of a 2 hour session with TB regarding secure user connections to the processor. Here's the rundown:
TSR -310s can't connect at all and are added to the blocked user list. CP4 logs the error regarding the remotes. Added a new user just for the TSRs to connect to and increased the authorization level from connects to user.? Still no connections. Upgraded the firmware of one TSR to the version released this morning.? Cleared everything out, rebooted, and added it all back in ... still no connection. TB support told me that mobile device users for projects that are hosted on the processor are now required to be authorization level of operators. So, he said why not try that "just for kicks", although this shouldn't be the case for "non-hosted" projects. Added a new user for the TSRs with operator user level, cleared out the remotes and blocked users, rebooted everything, and added csauthentication and IP Table entries. Woohoo!!!? TSR with the latest firmware (2.001.0095.001) connects!? TSR with the last version fails to connect. This is all getting quite ridiculous! TB couldn't explain why the TSW connected fine with a lower user level but the TSRs wouldn't. Yet another mystery related to new firmware combinations! So, when in doubt, set the authentication for device connections to an operator. Good luck! Brian |
Re: Ubiquiti wifi extender
#bestpractices
¿ªÔÆÌåÓýSo, as an addition to the coax method, you can use DirecTV DECA3 adapters ¨C one on each end ¨C and get 10/100 way beyond 100 meters even over rg-59.? I think you can actually get about 1000 feet over rg-6 if your cable is good with no intermediate splices.? DECA3 are usually available on ebay for under 15 bucks apiece.? Don¡¯t forget to get the 12V power supply also.? https://www.ebay.com/itm/323782964503?epid=20033524024&hash=item4b62f7f517:g:tBkAAOSw73xeaob8 ? From: <[email protected]> on behalf of ckangis <chris@...> ? Although I wouldn't design a network around this (hard-wared dedicated CAT lines are always best!) I have used the following in a pinch and they do work well: |
Re: Error: CPHProcessor.exe # 2021-06-13 23:55:47 # Failed to allocate memory for response in respond api
I'll keep an eye on this over the next couple of weeks.
This is my home system and I get emails whenever the system re-starts so I should know for sure in the next 3-4 days if turning off the cloud bs & fw update made any difference. CPU load has dropped a couple of percentage points. Used to idle about 25% now 23ish. Cheers -s |
Re: Error: CPHProcessor.exe # 2021-06-13 23:55:47 # Failed to allocate memory for response in respond api
Thanks chaps.
FW: 1.601.3935.28796 No ports forwarded to the internet Lincoln. I'll turn off all the cloud crap. I see?1.8000.0014 is now up so I'll try that as well. From the Release notes: Updates:
|
Re: Error: CPHProcessor.exe # 2021-06-13 23:55:47 # Failed to allocate memory for response in respond api
¿ªÔÆÌåÓýAnd do you have any ports forwarded to it from the internet (or if it¡¯s in a place like a University¡ do ACLs allow traffic from any potentially hostile ranges, e.g. students)? ? -- Lincoln King-Cliby, CTS, DMC-E-4K/T/D ? From: [email protected] [mailto:[email protected]]
On Behalf Of ckangis
Sent: Monday, June 14, 2021 8:29 AM To: [email protected] Subject: Re: [crestron] Error: CPHProcessor.exe # 2021-06-13 23:55:47 # Failed to allocate memory for response in respond api ? What FW version? |
Error: CPHProcessor.exe # 2021-06-13 23:55:47 # Failed to allocate memory for response in respond api
Anyone know what these errors mean?
They started appearing a couple of months ago on my lighting DIN-AP3. This has been running for a couple of years with no significant changes made to programming in that time. Happens every 4 days or so then the AP3 reboots as it's obviously run out of memory Error: CPHProcessor.exe # 2021-06-13 23:55:47? # Failed to allocate memory for response in respond api Error: CPHProcessor.exe # 2021-06-14 00:07:08? # Failed to allocate memory for response in respond api
Error: CPHProcessor.exe # 2021-06-14 00:18:29? # Failed to allocate memory for response in respond api
Error: CPHProcessor.exe # 2021-06-14 00:29:50? # Failed to allocate memory for response in respond api
Error: CPHProcessor.exe # 2021-06-14 00:41:10? # Failed to allocate memory for response in respond api
Error: CPHProcessor.exe # 2021-06-14 00:52:32? # Failed to allocate memory for response in respond api
Error: CPHProcessor.exe # 2021-06-14 01:03:53? # Failed to allocate memory for response in respond api
Error: CPHProcessor.exe # 2021-06-14 01:15:14? # Failed to allocate memory for response in respond api
Error: CloudClient.exe # 2021-06-14 01:20:12? # FTCtransPort: failedSystem.OutOfMemoryException: OutOfMemoryException
? ?at System.Threading.Thread..ctor(ThreadStart start, Int32 maxStackSize, Boolean check)
? ?at System.Threading.Thread..ctor(ThreadStart start)
? ?at Crestron.CloudClient.CloudTransError: CloudClient.exe # 2021-06-14 01:20:12? # port.sendViaTransport(CloudResponseManager& session, Stream xml, Int32 status)
? ?at Crestron.CloudClient.CloudDataCollector.CallbackFunction(Int32 stat)
? ?at Crestron.CloudClient.CloudDataCollector.frameIt()
? ?at Crestron.CloudClient.CloudDataCollecError: CloudClient.exe # 2021-06-14 01:20:12? # tor.requestFrame(CloudResponseManager& session, CloudRegisterFrameCallback func)
? ?at Crestron.CloudClient.CloudClient.issueFrameRequest(FRAMETYPE frameType)
? ?at Crestron.CloudClient.CloudClient.OnTimedEvent(Object source)
? ?at System.Threading.TimError: CloudClient.exe # 2021-06-14 01:20:12? # er.ring()
?
?
Error: CPHProcessor.exe # 2021-06-14 01:26:36? # Failed to allocate memory for response in respond api
Error: CPHProcessor.exe # 2021-06-14 01:37:57? # Failed to allocate memory for response in respond api
Error: CPHProcessor.exe # 2021-06-14 01:49:19? # Failed to allocate memory for response in respond api
Error: CPHProcessor.exe # 2021-06-14 02:00:41? # Failed to allocate memory for response in respond api
Error: CPHProcessor.exe # 2021-06-14 02:12:01? # Failed to allocate memory for response in respond api
Error: CPHProcessor.exe # 2021-06-14 02:23:22? # Failed to allocate memory for response in respond api
Error: CPHProcessor.exe # 2021-06-14 02:34:43? # Failed to allocate memory for response in respond api
Error: CPHProcessor.exe # 2021-06-14 02:46:05? # Failed to allocate memory for response in respond api
Error: CPHProcessor.exe # 2021-06-14 02:57:25? # Failed to allocate memory for response in respond api
Error: CPHProcessor.exe # 2021-06-14 03:08:46? # Failed to allocate memory for response in respond api
Error: CPHProcessor.exe # 2021-06-14 03:20:08? # Failed to allocate memory for response in respond api
Error: CPHProcessor.exe # 2021-06-14 03:31:29? # Failed to allocate memory for response in respond api
Error: CPHProcessor.exe # 2021-06-14 03:42:51? # Failed to allocate memory for response in respond api
Error: CPHProcessor.exe # 2021-06-14 03:54:13? # Failed to allocate memory for response in respond api
Cheers -s |
Re: CP4 versiports "locking up"
¿ªÔÆÌåÓýHi, ? thanks for all the responses. I?ve opened a ticket with TB, ticket numer ? To those who also have the same issue: Could you please open a ticket as well if not done already? I?d prefer to have that fixed rather than swapping out the control processor ? ? Thanks, Thorsten ? Von: [email protected] <[email protected]> Im Auftrag von Oliver Pemberton ? I'm glad it's not just me. I have seen IR just stop working on a CP4 until a reboot. In fact 2 out of 3 jobs where we replaced a 3 series with a 4 series we've ended up putting the 3 series back in to maintain reliability. ? OP |
Re: Color Picker
#smartgraphics
¿ªÔÆÌåÓýUse a serial buffer. The analog buffer (assuming those are the ¡°buffers¡± you¡¯re using) will pass input to output on the rising edge of enable if they are not the same; the serial buffer does nothing on the rising edge but passes values as they change while enable is high. ? -- Lincoln King-Cliby, CTS, DMC-E-4K/T/D ? From: [email protected] [mailto:[email protected]]
On Behalf Of Gloomy Goose
Sent: Sunday, June 13, 2021 6:20 PM To: [email protected] Subject: [crestron] Color Picker #smartgraphics ? Hello team, question about Color Picker widget. |
Re: CP4 versiports "locking up"
¿ªÔÆÌåÓý
I'm glad it's not just me. I have seen IR just stop working on a CP4 until a reboot.
In fact 2 out of 3 jobs where we replaced a 3 series with a 4 series we've ended up putting the 3 series back in to maintain reliability.
OP
|
Re: Log Entry, continuous and inexplicable
Okay, I will take a stab at your question.
First off, it is just an "info" entry so it doesn't? necessarily mean anything that is important.? Personally, I wish Crestron would give us a way to turn off all these useless messages.? Many devices have a setting were you can set the severity of the messages that get log.? Whether there is some way to set that in Crestron, is anyone's guess. Second, I am guessing this is either a message generated by C# itself or by the code that Crestron is written.? Not being a C# expert (or even a novice as that goes), that would be way out my realm to to say this is actually the case. But I did try to implement my own web socket implementation about a year ago (using C programming language).? The protocol is described in RFC6455 and actually is a pretty simple protocol.?? ? This message is probably referring to using TLS encryption which is not a requirement to use Web Sockets.? I actually was successful in partially implementing my own web socket connection only to find that the web browser then said it was changing the compression method (it didn't give me a choice).? I gave up at that point and started using the websocket functionality built in Node JS instead. If you look at RFC6455, the word certificate is only mention twice. Here If /secure/ is true, the client MUST perform a TLS handshake over the connection after opening the connection and before sending the handshake data []. If this fails (e.g., the server's certificate could not be verified), then the client MUST _Fail the WebSocket Connection_ and abort the connection. Otherwise, all further communication on this channel MUST run through the encrypted tunnel []. And here 1015 is a reserved value and MUST NOT be set as a status code in a Close control frame by an endpoint. It is designated for use in applications expecting a status code to indicate that the connection was closed due to a failure to perform a TLS handshake (e.g., the server certificate can't be verified). So my wild guess is the websocket connection using the server certificate failed because it was an unsigned certificate and so the connection reverted to a different method using the client's certificate.? Of course, I am probably totally wrong. Probably more information then you needed . Steve |
Re: CP4 versiports "locking up"
My CP4 has also started losing it's IOs. I haven't tried many firmwares but did load a new one and new SIMPL when the issue first popped up. Didn't seem to help. Also running only one program. On Sun, Jun 13, 2021 at 1:42 AM Miles Redbart <miles@...> wrote: We are also just running 1 prog on the CP4 but using all 8 gpio¡¯s for simple zero contact sensors ip¡¯s. We find exactly the same issue that they all lock up and the only way to re-instate them is either a prog restart of a processor reboot. However as mentioned it was a fully functional program working on a CP3 for years without any problems. Tried many different FW but had more issues so remain on 2.4474.00017 and just live with the random reboots required. Nothing in the error log that looks suspicious and I have not raised this with TB.? |
Re: CP4 versiports "locking up"
We are also just running 1 prog on the CP4 but using all 8 gpio¡¯s for simple zero contact sensors ip¡¯s. We find exactly the same issue that they all lock up and the only way to re-instate them is either a prog restart of a processor reboot. However as mentioned it was a fully functional program working on a CP3 for years without any problems. Tried many different FW but had more issues so remain on 2.4474.00017 and just live with the random reboots required. Nothing in the error log that looks suspicious and I have not raised this with TB.?
|