MULTIPLE DISPLAY CONTROL PROTOCOL OVER IP ?
SAMSUNG MDC PORT TCP/IP PORT 1515 USE SAME MODULES AS RS232 BUT WITH TCP/IP PORT1515
? ? ?
? ? 1
? ? ?
Samsung Commercial TV 9600/8/1/N 3rd Byte is TV address
? ID #1 ALL ID #'S
TV On \xAA\x11\x01\x01\x01\x14 \xAA\x11\xFE\x01\x01\x11
TV Off \xAA\x11\x01\x01\x00\x13 \xAA\x11\xFE\x01\x00\x10
HDMI 1 Input \xAA\x14\x01\x01\x21\x37 \xAA\x14\xFE\x01\x21\x34
HDMI 2 Input \xAA\x14\x01\x01\x23\x39 \xAA\x14\xFE\x01\x23\x36
HDMI 3 Input ? \xAA\x14\xFE\x01\x31\x44
DVI Input \xAA\x14\x01\x01\x18\x2E ?
Component Input \xAA\x14\x01\x01\x08\x1E ?
MUTE ON \xAA\x13\x01\x01\x01\x16 \xAA\x13\xFE\x01\x01\x1
MUTE OFF \xAA\x13\x01\x01\x00\x15 \xAA\x13\xFE\x01\x00\x12
? ? ?
VOLUME SET TO “0” \xAA\x12\x01\x01\x00\x14 ?
VLUME SET TO “32” 50% \xAA\x12\x01\x01\x32\x46 ?
VOLUME SET TO “MAX” \xAA\x12\x01\x01\x64\x78 ?
VOLUME UP ? \xAA\x62\xFE\x01\x00\x61
VOLUME DOWN ? \xAA\x62\xFE\x01\x01\x62
Query Power \xAA\X11\X01\X00\X12 ?
Query Source \xAA\X14\X01\X00\X15 ?
Query Mute \xAA\X13\X01\X00\X14 ?
Query Volume \xAA\X12\X01\X00\X13 ?
? ? ?
power is on FB \xAA\xFF\x01\x03\x41\x11\x01\x00 \xAA\xFF\x01\x03\x41\x11\x01\x56
power is off FB \xAA\xFF\x01\x03\x41\x11\x00\x00 \xAA\xFF\x01\x03\x41\x11\x00\x55
mute is on FB \xAA\xFF\x01\x03\x41\x13\x01\x00 ?
mute is off FB \xAA\xFF\x01\x03\x41\x13\x00\x00 ?
source is video FB \xAA\xFF\x01\x03\x41\x14\x0C\x00 ?
source is Svideo FB \xAA\xFF\x01\x03\x41\x14\x04\x00 ?
source is component FB \xAA\xFF\x01\x03\x41\x14\x08\x00 ?
SOURCE IS HDMI 1 \xAA\xFF\x01\x03\x41\x14\x21\x79 ?
SOURCE IS HDMI 2 \xAA\xFF\x01\x03\x41\x14\x22\x7A ?
SOURCE IS HDMI 3 \xAA\xFF\x01\x03\x41\x14\x23\x7B ?
SOURCE IS HDMI 4 \xAA\xFF\x01\x03\x41\x14\x24\x7C ?
Volume FB \xAA\xFF\x01\x03\x41\x12\x[volume byte] Span 65535, divisor 100d, offset 0d
MUTE IS ON \xAA\xFF\x01\x03\x41\x13\x01\x58 ?
MUTE IS OFF \xAA\xFF\x01\x03\x41\x13\x00\x57 ?
? ? ?


Re: DIN-AP3 Default Login?

 

UPDATE:
Going on 4+?hours with TB on phone and remote session.? After 2 hour drive to site.
Just to remove a chandelier from a scene button.


Re: Denon HEOS and the Media Player Object

 

Yes, module is available at the application market.?


On Wed, Nov 18, 2020 at 9:24 AM ckangis <chris@...> wrote:
bump...


Re: Simpl 4.14.21.00

 

You are going to want to have a build environment with the pre-200 databases, 4.11 SIMPL, and 6.2.0.3 VT Pro-E. What I ended up doing since I only want to carry one laptop with me anywhere is I spun up a Hyper-V virtual machine and installed all the old versions of those tools and copied over all my modules, smart graphics themes, etc. in their current state into the VM. That way I can still manage existing code, but also move forward with new Crestron software. I have not had any issues with the updated versions of modules that support the new databases in the newest SIMPL thus far. Good luck!

-Stuart


Re: DIN-AP3 Default Login?

 

Had a AV3 the other day that defaulted to usrname:crestron pw: crestron when I updated the firmware


Re: Denon HEOS and the Media Player Object

 

bump...


Re: Sonos S1 Websock Exception Thrown

 

As far as I know, there aren't separate access levels for the FTP site - you're either in, or not. The beta folder should be at the top of the root directory, when sorted alphabetically. However, if you still can't find it, I'm sure Tech Support can send it to you.

I just heard back from a dealer I sent a newly-compiled program to yesterday, and he said this database *DOES* fix the Sonos issues. Hopefully there will be a public release soon.

--- On Wednesday, November 18, 2020 at 9:03 AM, johnh wrote:

Tony I dont even see any Beta folders on the FTP using Filezilla. Maybe i'm not
worthy


Re: Lutron Quantum Phantom Keypad Button Commands

 

开云体育

In Quantum you can definitely use a real keypad ID (I’ve never used the NWK ID…everything Ive done with Qantum is either keypads or areas) … two most common ways are there’s a physical keypad on the Quantum system that you want to duplicate – just need it’s ID from the integration report and send the appropriate #DEVICE command for the type of keypad. If you don’t have the integration report you can turn monitoring on on the NWK and press a button on the keypad and see what ID/integration ID gets reported.

?

Or there’s a “virtual” or “phantom” keypad that doesn’t exist in reality but is otherwise programmed exactly the same as the above. The only problem is in Quantum a phantom keypad must be assigned to a link for it to work – it is possible to create a phantom keypad but not assign it to a link and then “nothing works” so to speak.

?

Lincoln

?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Diamond)
ControlWorks Consulting, LLC
Direct: (+1)440.771.4807 | Cleveland: (+1)440.449.1100? | Boston: (+1)508.695.0188 | DC: (+1)202.381.9070? | Fax: (+1)440.449.1106
Crestron Services Provider | Biamp Authorized Independent Programmers | Extron Qualified Independent Programmer

?

From: [email protected] <[email protected]> On Behalf Of johnh@...
Sent: Wednesday, November 18, 2020 8:18 AM
To: [email protected]
Subject: Re: [crestron] Lutron Quantum Phantom Keypad Button Commands

?

Yes because you are only talking to the NWK and not the Quantum system. I am not a Quantum guy, but in the Quantum portion of the Integration Protocol there are no Quantum direct keypad press commands, just output,? area, and shade group commands. Looks like the Quantum programmer will need to assign your buttons to the NWK


Re: Sonos S1 Websock Exception Thrown

 

Tony I dont even see any Beta folders on the FTP using Filezilla. Maybe i'm not worthy


Re: Lutron Quantum Phantom Keypad Button Commands

 

Yes because you are only talking to the NWK and not the Quantum system. I am not a Quantum guy, but in the Quantum portion of the Integration Protocol there are no Quantum direct keypad press commands, just output,? area, and shade group commands. Looks like the Quantum programmer will need to assign your buttons to the NWK


Re: DIN-AP3 Default Login?

 

开云体育

Unfortunately the “serial number as password” (I know Extron is don’t that, haven’t seen it from Crestron and hope that they find a different bandwagon to jump on) is an effect of a California law that prohibits shipping devices with standard credentials…. Well meaning (e.g. make it harder for ignorant home users from letting their IoT devices be compromised) but incredibly annoying for devices that aren’t connected to a network that even has Internet/outside world access let alone exposed directly to the Internet.

?

What is troubling is that processors and touchpanels seem to enforce different password complexity requirements. I was at a site a couple weeks ago and the processor happily accepted “admin” “clientname” but the touchpanel wouldn’t take “clientname” or “Clientname”, I wound up having to use “C1ientname” for the panels

?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Diamond)
ControlWorks Consulting, LLC
Direct: (+1)440.771.4807 | Cleveland: (+1)440.449.1100? | Boston: (+1)508.695.0188 | DC: (+1)202.381.9070? | Fax: (+1)440.449.1106
Crestron Services Provider | Biamp Authorized Independent Programmers | Extron Qualified Independent Programmer

?

From: [email protected] <[email protected]> On Behalf Of Steve Adams
Sent: Wednesday, November 18, 2020 8:08 AM
To: [email protected]
Subject: Re: [crestron] DIN-AP3 Default Login?

?

A lot of Crestron units are now using admin as the username and crestron as the default password, all lower case. I have also heard that some products are using admin as the username and the serial number as the password (Old Polycom trick), good luck.

?

Steve Adams

?

?

?

?

On Wednesday, November 18, 2020, 01:44:52 AM CST, Math Leenen | Emenem Building Automation <m.leenen@...> wrote:

?

?

Have you tried both userid/password empty?

?

Van: [email protected] <[email protected]> Namens markcrestrongroup
Verzonden: woensdag 18 november 2020 02:52
Aan: [email protected]
Onderwerp: [crestron] DIN-AP3 Default Login?

?

Local onsite I connect to client's DIN-AP3 via CTP ("out of the box").? All is/was good.
Now I am connected via VPN, and am now getting a username/password prompt in Toolbox to connect to DIN-AP3 on its LAN address..
I've tried "crestron" and no password, plus all the usual suspects.
I never enabled SSH or anything, the DIN-AP3 was right out of the box.
Am I looking at a 4 hour round trip tomorrow?
Thanks.


Re: DIN-AP3 Default Login?

 

A lot of Crestron units are now using admin as the username and crestron as the default password, all lower case. I have also heard that some products are using admin as the username and the serial number as the password (Old Polycom trick), good luck.

Steve Adams




On Wednesday, November 18, 2020, 01:44:52 AM CST, Math Leenen | Emenem Building Automation <m.leenen@...> wrote:


Have you tried both userid/password empty?

?

Van: [email protected] <[email protected]> Namens markcrestrongroup
Verzonden: woensdag 18 november 2020 02:52
Aan: [email protected]
Onderwerp: [crestron] DIN-AP3 Default Login?

?

Local onsite I connect to client's DIN-AP3 via CTP ("out of the box").? All is/was good.
Now I am connected via VPN, and am now getting a username/password prompt in Toolbox to connect to DIN-AP3 on its LAN address..
I've tried "crestron" and no password, plus all the usual suspects.
I never enabled SSH or anything, the DIN-AP3 was right out of the box.
Am I looking at a 4 hour round trip tomorrow?
Thanks.


Re: SWAMP Zone Names - Toolbox

 

Are you feeding the Source and Room names into the Hardware definition, in SMW??
Assuming you are, do you have an MSP on the strings? Because the Swamp takes time to fully connect, the strings will be lost if they're just initialized on startup. Even if you're using the Device Ready Pulse to trigger the strings, I'd still use the MSP to lock them in....
Sorry if this is too basic, but we all miss the obvious sometimes!...:)


Re: Security suggestions for a very large system

 

开云体育

A lot of large/enterprise-y access control systems support thousands of zones of monitoring – I’m not sure to what extent any are integratable – but whether or not “no combining of devices” is realistic or not really depends on the application. A simple residence, no that doesn’t make a ton of sense.

?

A HVI, HVP or corporate/campus security environment that’s absolutely the right (and only, IMO) way to go – it allows not only pin-pointing of an incident occurred, and for things like art which specific piece of art has been disturbed, but in an active incident (e.g. active shooter, burglary in progress, etc.) allows a tremendous amount of insight as to where precisely someone is in the building as well as the path they are taking.

?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Diamond)
ControlWorks Consulting, LLC
Direct: (+1)440.771.4807 | Cleveland: (+1)440.449.1100? | Boston: (+1)508.695.0188 | DC: (+1)202.381.9070? | Fax: (+1)440.449.1106
Crestron Services Provider | Biamp Authorized Independent Programmers | Extron Qualified Independent Programmer

?

From: [email protected] <[email protected]> On Behalf Of gablerjohn
Sent: Wednesday, November 18, 2020 7:55 AM
To: [email protected]
Subject: Re: [crestron] Security suggestions for a very large system

?

We have all been there.? An unrealistic specification that we must meet.? I'm looking at 300+ zones that are specified, just because of 1 simple statement in the specification.? "No combining of devices to the same zone"? I am looking at Vista 250BPT, but maxes at 242 zones.


Re: Security suggestions for a very large system

 

We have all been there.? An unrealistic specification that we must meet.? I'm looking at 300+ zones that are specified, just because of 1 simple statement in the specification.? "No combining of devices to the same zone"? I am looking at Vista 250BPT, but maxes at 242 zones.


Re: DIN-AP3 Default Login?

 

开云体育

Hi,

i had this happening in the past when there was another device on the LAN with the same IP address as the Crestron controller. (customer said IP is free but it wasn?t…).

Actually, this happens always if you try to connect to a non Crestron-device.

So it?s probably worth switching off the controller and see if there?s still a device with the controllers IP address responding.

Cheers, Thorsten

?

?

Von: [email protected] <[email protected]> Im Auftrag von markcrestrongroup
Gesendet: Mittwoch, 18. November 2020 02:52
An: [email protected]
Betreff: [crestron] DIN-AP3 Default Login?

?

Local onsite I connect to client's DIN-AP3 via CTP ("out of the box").? All is/was good.
Now I am connected via VPN, and am now getting a username/password prompt in Toolbox to connect to DIN-AP3 on its LAN address..
I've tried "crestron" and no password, plus all the usual suspects.
I never enabled SSH or anything, the DIN-AP3 was right out of the box.
Am I looking at a 4 hour round trip tomorrow?
Thanks.


Re: DIN-AP3 Default Login?

 

开云体育

Have you tried both userid/password empty?

?

Van: [email protected] <[email protected]> Namens markcrestrongroup
Verzonden: woensdag 18 november 2020 02:52
Aan: [email protected]
Onderwerp: [crestron] DIN-AP3 Default Login?

?

Local onsite I connect to client's DIN-AP3 via CTP ("out of the box").? All is/was good.
Now I am connected via VPN, and am now getting a username/password prompt in Toolbox to connect to DIN-AP3 on its LAN address..
I've tried "crestron" and no password, plus all the usual suspects.
I never enabled SSH or anything, the DIN-AP3 was right out of the box.
Am I looking at a 4 hour round trip tomorrow?
Thanks.


Re: Global Cache Series 3 Module

 

Yes same problem I have


Re: DIN-AP3 Default Login?

 

开云体育

If there is a cp3 on the project on the same vlan, you could load up a program with the ssh module in slot 2 and have it connect to the ap3 on port 22 and see if the default gateway is jacked. Just use debugger on the tx line to send data to the ap3.?

I did this a while ago on an amp that had the wrong gateway, except instead of ssh I just used a TCP/IP client on 41795. This is slightly different but should work.?

Doesn't help if you have the wrong credentials though...

Caleb Radecky |?Manager, Online Products & Services
Crestron Silver Certified Programmer | DMC-D-4K | DMC-E-4K
ControlWorks Consulting, LLC |?Crestron Services Provider?| 8228 Mayfield Rd. Suite 6B Rear, Cleveland OH 44026
D.?440.771.4809 |?O.440.449.1100?X1109 | F.440.449.1106 |


From: Steve Kuehn <steve@...>
Sent: Tuesday, November 17, 2020 22:59
To: [email protected]
Subject: Re: [crestron] DIN-AP3 Default Login?

You should be aware that the latest firmware releases will require authentication upon a restore.? Basically, it looks like Crestron is forcing everyone to use authentication.? Possible there is a bug in the latest firmware were something happened and it got enabled.

You could do a port scan on your DIN-AP3 via the VPN and see if the CTP port is even open.? I personally use either nmap or zenmap to do this.? But I do this from a Linux environment.? But I believe those tools have been ported to Windows too if you are using Windows.

For example to scan common Crestron ports, you would execute this:
nmap -p 41790-41799 192.168.17.202
Here is the response from my processor that does not have ssh enabled
Starting Nmap 7.01 ( https://nmap.org ) at 2020-11-17 21:54 CST
Nmap scan report for MP2E (xx.xx.xx.xx)
Host is up (0.010s latency).
PORT????? STATE? SERVICE
41790/tcp open?? unknown
41791/tcp closed unknown
41792/tcp closed unknown
41793/tcp closed unknown
41794/tcp open?? crestron-cip
41795/tcp open?? crestron-ctp
41796/tcp closed unknown
41797/tcp closed unknown
41798/tcp closed unknown
41799/tcp closed unknown


Re: DIN-AP3 Default Login?

 
Edited

You should be aware that the latest firmware releases will require authentication upon a restore.? Basically, it looks like Crestron is forcing everyone to use authentication.? Possible there is a bug in the latest firmware were something happened and it got enabled.

You could do a port scan on your DIN-AP3 via the VPN and see if the CTP port is even open.? I personally use either nmap or zenmap to do this.? But I do this from a Linux environment.? But I believe those tools have been ported to Windows too if you are using Windows.

For example to scan common Crestron ports, you would execute this:
nmap -p 41790-41799 192.168.17.202

Here is the response from my processor that does not have authentication enabled
Starting Nmap 7.01 ( https://nmap.org ) at 2020-11-17 21:54 CST
Nmap scan report for MP2E (xx.xx.xx.xx)
Host is up (0.010s latency).
PORT????? STATE? SERVICE
41790/tcp open?? unknown
41791/tcp closed unknown
41792/tcp closed unknown
41793/tcp closed unknown
41794/tcp open?? crestron-cip
41795/tcp open?? crestron-ctp
41796/tcp closed unknown
41797/tcp closed unknown
41798/tcp closed unknown
41799/tcp closed unknown

And here is a port scan on a CP4R via a OpenVPN tunnel that has authentication enabled;
Starting Nmap 7.01 ( https://nmap.org ) at 2020-11-17 22:09 CST
Nmap scan report for 192.168.17.202
Host is up (0.038s latency).
PORT????? STATE? SERVICE
41790/tcp closed unknown
41791/tcp closed unknown
41792/tcp closed unknown
41793/tcp closed unknown
41794/tcp open?? crestron-cip
41795/tcp closed crestron-ctp
41796/tcp open?? unknown
41797/tcp closed unknown
41798/tcp closed unknown
41799/tcp closed unknown