Re: PAD8 alternatives
Why did they get rid of the PAD8A in the first place? It could not have been very expensive to build. Simple to program, works without a fuss, starts up instantly.
By PD · #237441 ·
Re: Compile error - must be declared as digital, analog, or serial.
These comments are all very helpful. ?I've gone into the Simpl module. ?There are things in the program that do not connect to the module. ?I think the previous programmer must have upgraded the
By Bob Baxter · #237440 ·
Re: Compile error - must be declared as digital, analog, or serial.
Sounds to me like the HVAC module was set to compile only for a Series 2 and not a Series 3.? Try opening the HVAC modules (SIMPL and SIMPL+) and set the compile settings to both Series 2 and Series
By Steve Kuehn · #237439 ·
Re: Compile error - must be declared as digital, analog, or serial.
Buffer the green signals Please feel free to contact me if you have any questions or if I can help you in any way Have a great day. Gregory Davis 631-806-5661
By Gregory Davis · #237438 ·
Re: Compile error - must be declared as digital, analog, or serial.
Green is ambiguous ¨C the symbol on the other end can take either a serial or analog and the compiler doesn¡¯t have enough information to figure out which you intended it to be. A lot of times this
By Lincoln King-Cliby · #237436 ·
Compile error - must be declared as digital, analog, or serial.
I've inherited an existing program written mostly in simpl and runs on an pro2. ?The client want to upgrade the processor to a pro3. ?I swapped out the Pro2 for a Pro 3. ?I directly swiped the
By Bob Baxter · #237435 ·
Re: PAD8 alternatives
I still think its ridiculous that Crestron can make all these different HDMI switching widgets but refuse to give us a modern PAD8 replacement in the form of a simple analog audio matrix. How hard
By @johnmax · #237433 ·
Re: VS-88A
See if this helps. https://k.kramerav.com/support/download.asp?f=35567 -- Kenny Hays 502-419-2287
By Kenny Hays · #237432 ·
Re: Sonos S2 on TSW-xx60 Touch Panels
What is the issue with them updating the native app on the tsw panels?
By smurfsarecool2002 · #237431 ·
VS-88A
Hi , Need help in controlling VS-88A i have tried protocol 2000 and 3000 it doesn't work. I'm using cp3n. thanks, Kenneth
By jken11@... · #237430 ·
Re: Crestron Home vs. Original Simpl and VT
Hi Steve, I think your opinion here might change with some hands-on experience.? Personally, I'm not on the "cloud" bandwagon ("cloud is the name for someone else's computer" etc. etc.) but in this
By Oliver Hall · #237429 ·
Re: Denon Avr
Hm, doesn?t have RS232 or even LAN¡­ I guess you have to go IR. Von: [email protected] <[email protected]> Im Auftrag von Zedd Log Gesendet: Donnerstag, 1. Oktober 2020 05:19 An:
By Thorsten K?hler · #237428 ·
Denon Avr
Hi guys any module compatible for this unit?Denon AVR-X250BT
By Zedd Log · #237427 ·
Re: Simpl+ parse integer value
Your correct lol Denon. However I did not see any IP modules mostly just IR. I did not check application market, I worked out the code anyway. Appreciate the response of course.
By Dillon Costanza · #237426 ·
Re: Sonos S2 on TSW-xx60 Touch Panels
Got it, thanks Mitch!
By markcrestrongroup · #237425 ·
Re: Simpl+ parse integer value
Sounds like a Denon AVR. There are loads of Denon modules in the files section here and on the application market. -s
By Slip Cougan · #237424 ·
Re: Control 4 - C4-AMP108 - 16 Channel Amplifier - Quality?
If you can squeeze it in, the Snap AV amp might do the trick. Their 16 channel amp is 12.2" deep. I haven't used it, but their products are usually pretty reliable, as is their support. Also, your
By Brian Matson · #237423 ·
ICT Protege WX Anyone controlled one?
I am looking to talk to a ICT Protege WX for control of a few doors that are connected to it. just looking to open/close or hold open, release doors. Anyone done it before?
By j5races · #237422 ·
Re: Control 4 - C4-AMP108 - 16 Channel Amplifier - Quality?
I would not recommend using one of these amplifiers. They have a known issue with the capacitors and cannot be repaired. Jonathan A. Boatman jonathan.boatman@... 951-732-7331
By Macross · #237421 ·
Control 4 - C4-AMP108 - 16 Channel Amplifier - Quality?
Anyone who has mixed up their control system life ever touch one of these units?? What are your thoughts?? I am in a limited space scenario, and on something of a budget for a client and was looking
By simpl_2_use · #237420 ·