Re: NVX and DANTE on Cisco 2960-x Switches

 

What specific issue are you having with Dante? Discovery? Dropouts? Clocking?

if it¡¯s discovery then you likely have an issue with broadcast traffic or your controller PC is on a different VLAN.?

if it¡¯s clocking then you might just need to enable QoS

NVX and Dante need to be on the same VLAN especially when using 352s?


DMPS3-4K-100-C network connection issue

 

Has anyone experienced network issues with the DMPS3-4K-100-C? If I disconnect the network cable then reconnect, I don't get network activity but if I disconnect a second time and reconnect it appears to work. This has happen about 30 days ago and Crestron issued an advanced replacement.
Firmware is current, tried different cables, network switches and rolled back firmware as well still with the same results.


Re: TSW-x52 non Crestron mac address

 

Don't you think it's a little early to be drinking? Or am I late to the party? With no InfoComm, my body is a little confused right now.?


Denon 508MX Mixer

 

Anyone have a module or has worked with these units ??


Re: NVX and DANTE on Cisco 2960-x Switches

 

Maybe you need use different VLANs to NVX and Dante.
You need check if the switch capacity of processing is ok (bandwidth). I think this is not your problem, but, a doble check can help you.

Maybe this doc can help you.

If you can use the NVX in your configs, i Think you is able tu use Dante.
Try remove all NVX and check if your dante work.

On Tue, Jun 23, 2020 at 12:13 PM <williamtejral@...> wrote:
I am working on? a system using NVX-352 as DANTE sources.There are 15 NVX-352, 14 NVX-D30, and 20 other DANTE devices. I have been trying to get the switches configured correctly. I was able to get the NVX system working on 3 Pakedge S3L-24P switches, but could not get the DANTE to work at all. We changed to CIsco 2960-X, but I am unable to find the correct settings in the CIsco manual and most examples are for 300 series switches. I currently have 2 NVX-352 and the Cisco and have turn turned on the NVX stream, just using DANTE.? Has anyone used this type of configuration and maybe have an idea of what I am missing? I have a feeling it is something very obvious. Thanks, Bill


NVX and DANTE on Cisco 2960-x Switches

 

I am working on? a system using NVX-352 as DANTE sources.There are 15 NVX-352, 14 NVX-D30, and 20 other DANTE devices. I have been trying to get the switches configured correctly. I was able to get the NVX system working on 3 Pakedge S3L-24P switches, but could not get the DANTE to work at all. We changed to CIsco 2960-X, but I am unable to find the correct settings in the CIsco manual and most examples are for 300 series switches. I currently have 2 NVX-352 and the Cisco and have turn turned on the NVX stream, just using DANTE.? Has anyone used this type of configuration and maybe have an idea of what I am missing? I have a feeling it is something very obvious. Thanks, Bill


Re: Insteon Lighting Control

 

@Julio - email sent. Hope you find it helpful.


Re: TSW-x52 non Crestron mac address

 

¿ªÔÆÌåÓý

Yeah, that joke gets used a lot in testing hardware ¨C it may have just not had the correct MAC programmed in. Not the first time. As long as you don¡¯t have another DEAD BEEF 1234 on the same network it shouldn¡¯t cause any real issues on its own. On the other hand check to make sure everything else is working as expected as there is a small chance that this could be a sign of an impending failure.

?

?

Lincoln

?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Diamond)
ControlWorks Consulting, LLC
Direct: (+1)440.771.4807 | Cleveland: (+1)440.449.1100? | Boston: (+1)508.695.0188 | DC: (+1)202.381.9070? | Fax: (+1)440.449.1106
Crestron Services Provider | Biamp Authorized Independent Programmers | Extron Qualified Independent Programmer

?

From: [email protected] <[email protected]> On Behalf Of plareeeiybusse
Sent: Tuesday, June 23, 2020 9:40 AM
To: [email protected]
Subject: Re: [crestron] TSW-x52 non Crestron mac address

?

Its reporting de:ea:be:ef:12:34


Re: TSW-x52 non Crestron mac address

 

¿ªÔÆÌåÓý

I¡¯m sorry¡­ I¡¯m not awake enough and ¡°it was touching itself in weird places¡± made me laugh a little too hard while drinking this morning¡­

?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Diamond)
ControlWorks Consulting, LLC
Direct: (+1)440.771.4807 | Cleveland: (+1)440.449.1100? | Boston: (+1)508.695.0188 | DC: (+1)202.381.9070? | Fax: (+1)440.449.1106
Crestron Services Provider | Biamp Authorized Independent Programmers | Extron Qualified Independent Programmer

?

From: [email protected] <[email protected]> On Behalf Of Rob
Sent: Tuesday, June 23, 2020 8:48 AM
To: [email protected]
Subject: Re: [crestron] TSW-x52 non Crestron mac address

?

Yes, I've had a TSW-760 report a weird MAC Address. I don't have record of what the MAC Address was, but the panel was defective out of the box (it was touching itself in weird places and calibration, restore, init, etc. wouldn't fix it). That was a fun call to True Blue when it reported both a bogus Serial Number (one not on our PO) AND a bogus MAC Address. The sticker satiated the claim, though, and we got an advanced replacement.?


Re: TSW-x52 non Crestron mac address

 

I've seen that one as well


Re: Avoid latest versions of SIMPL when programming for 2- or 3-series for now

 

The Biamp modules were version 1.5. Two workarounds seem to exist: rollback to the older SIMPL, or update the firmware on the processor. Either fix alone solved it. The program was from 5 years ago and I was only adding an XPanel to it, so I was trying to tread lightly.


Re: Program Restart. #console

 

Like Steve said, just reboot.? If you actually wanted to restart a program, though, it would be "progreset -p:1" for the program in slot 1.

On Sun, Jun 21, 2020 at 11:27 AM Steve Kuehn <steve@...> wrote:
I usually use "reboot" instead.? I am not even sure if "progreset" will cause the slave mode to take effect.

At least on my MC3 and MC2E, I don't need to supply any parameters with "progreset".?? I think you? only need to supply the parameters when you have multiple programs running.

    
On 6/21/20 2:37 AM, Sharan Suvarna via wrote:

Hi guys.

After adding the slave IP table in the console the control processor its asking me to "Restart program to take effect" , So I thought of using the "progreset" command. But I am not able figure out all the parameters in that command.?

?PROGRESET {-P:ALL | -P:Specific Program Identifier} {-V} {-D}

? -P:? Reset a specific program or ALL.? If not present, ALL assumed..

? -V:? Verbose reset.

? -D:? Don't keep DBGSIGNAL information (PROGRESET normally preserves DBGSIGNAL flags).

Could anyone help me out what does those parameters means ? What does the "-V" & "-D" means ?

Is there any other easier? command that would achieve this ?

Thank You.



Re: TSW-x52 non Crestron mac address

 

Its reporting de:ea:be:ef:12:34


Re: LG RS-232 Pinout

 

Thank you guys for the help!?

-andy


Re: TSW-x52 non Crestron mac address

 

Yes, I've had a TSW-760 report a weird MAC Address. I don't have record of what the MAC Address was, but the panel was defective out of the box (it was touching itself in weird places and calibration, restore, init, etc. wouldn't fix it). That was a fun call to True Blue when it reported both a bogus Serial Number (one not on our PO) AND a bogus MAC Address. The sticker satiated the claim, though, and we got an advanced replacement.?


Re: Hayward OmniLogic Crestron Module

 

I¡¯ve done a few. Couple things are strange about the Hayward. First it only controls the pool or the spa at any one time so not possible(or advisable) to have a single page that is pool and spa control. You have to press Pool then the temp read out for the current temp serial will he Pool, and of you press Spa then the same serial string now reports the Spa current temp.

Also the DNS has to be set. But you say that¡¯s covered.

The last gotcha I found is that the Site ID as they call it in the module is a different name on the Hayward site . It¡¯s like system ID or some other name I can¡¯t remember.


Re: LG RS-232 Pinout

 

¿ªÔÆÌåÓý

Make sure LG firmware is greater then 3.x.x. Version 3 has serial problems

Verstuurd vanaf mijn iPad

Op 22 jun. 2020 om 19:29 heeft Andy Ross <sifuas@...> het volgende geschreven:

?Hi everyone,

We are installing an LG display ( 86UH5E ) with RS-232 control through the 4-pin TRS connector.

Does anyone know which connections on the display are TX, RX and Ground?

Thanks,

-andy


Re: LG Refrigerator Module

 

The few pieces I put together seem to imply it's OAUTH or OAUTH2-based (or perhaps "inspired" -- parts definitely don't look like pure OAUTH) and despite being called an "open" API it appears LG's approval is needed to get the full API spec -- though admittedly I've not dug too far -- since no one answered "Yes, of course I have it done and working" [wasn't really expecting that answer, but also wasn't really thinking "what version of Android is this refrigerator running" would be a question during the appliance shopping process either] at this point I'm waiting for the fridge to be delivered and installed before I dive too deep.

But I get home from the apartment tomorrow, fridge gets delivered Thursday and then Friday I'm off to California for my dad's 70th over the weekend (shhhhh...no one tell him I'm coming. It's a surprise.) and with actual paying client obligations it will probably be a while before I dig too deep.

--
Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Diamond)
ControlWorks Consulting, LLC
Direct: (+1)440.771.4807 | Cleveland: (+1)440.449.1100? | Boston: (+1)508.695.0188 | DC: (+1)202.381.9070? | Fax: (+1)440.449.1106
Crestron Services Provider | Biamp Authorized Independent Programmers | Extron Qualified Independent Programmer

-----Original Message-----
From: [email protected] <[email protected]> On Behalf Of jbasen
Sent: Monday, June 22, 2020 10:06 PM
To: [email protected]; [email protected]
Subject: Re: [crestron] LG Refrigerator Module

Correct but when I looked at the information it was just model information for refrigerators or open source licensing info. Unlike other products there isn't any application source code that could be used to figure out the commands being sent.

------ Original Message ------
From: "j5races" <fueler1@...>
To: "[email protected]" <[email protected]>
Sent: 6/22/2020 8:20:41 AM
Subject: Re: [crestron] LG Refrigerator Module

Looks like pages 4,5,6 have Refrigerator info!



Re: LG Refrigerator Module

 

Correct but when I looked at the information it was just model information for refrigerators or open source licensing info. Unlike other products there isn't any application source code that could be used to figure out the commands being sent.

------ Original Message ------
From: "j5races" <fueler1@...>
To: "[email protected]" <[email protected]>
Sent: 6/22/2020 8:20:41 AM
Subject: Re: [crestron] LG Refrigerator Module

Looks like pages 4,5,6 have Refrigerator info!



Re: Samsung Flip2

 

Hi B B,?
Thanks for your help, I Really don't remember if I set another address.?
but I believe that in the same way the monitors should take some action or not?


On Mon, Jun 22, 2020 at 9:55 PM B B via <bb2479av=[email protected]> wrote:
If you are sending the ¡®all devices¡¯ address it will not return feedback. Use one address, set it on the television and see what happens.


On Jun 22, 2020, at 5:14 PM, TBB Automacao <tbbautomacao@...> wrote:

?
Hi all,
I need control the new version from Samsung Flip Monitor, (Flip 2 WM55R and WM65R). someone had a success to control?

I can control to previews version, but not on this newer; The Datasheet inform control by RS-232 and Ethernet, but i can't make it work.

On Monitor, I can see a fisical port called Service, on this port I treyed all Baud Rate and after with cross cable. Not worked.

I maked a port scan and I can see ports open: 7678, 9197, 26101 and 38485; ?None Worked.
On the Ports 7678 and 9197 I can keep connected, but do not have communication.

Commands that I Have is:
To Turn On: \xAA\x11\xFE\x01\x01\x11 and \x08\x22\x00\x00\x00\x02\xD4
To Turn Off: \xAA\x11\xFE\x01\x00\x10 and \x08\x22\x00\x00\x00\x01\xD5
?
At no time did I receive any kind of response.?
I managed to control some functions by CEC, but it doesn't have all the actions I would like.

Many Thanks