¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date

Re: Third party I/O

 

Global Cache


Sending commands to Echo

 

Maybe I have missed it, but I am wondering if we have a way to send commands to Alexa to operate things it controls that we do not currently have direct control of but it does. ?Is there a way for me to have Crestron tell Alexa to lock the door, for example.


Re: Password for this file?

 

It's located in the Utilities folder under Files.


Re: Password for this file?

 

I've loaded my version of the file in unlocked format. You will see it has the exact functionality as the original one, and feel free to update as you see fit.
Hope this helps.
Bill.


New file uploaded to Crestron

 

Hello,

This email message is a notification to let you know that
a file has been uploaded to the Files area of the Crestron
group.

File : /Schedule Input From User WP.zip
Uploaded by : williamprice880 <williamprice880@...>
Description : Schedule input from user S+ WPrice version. Unlocked source file.

You can access this file at the URL:


To learn more about file sharing for your group, please visit:


Regards,

williamprice880 <williamprice880@...>


Steamist shower and sauna control

 

Hey everyone,


I have this device connected to the network and I am trying to control with crestron, in the application market they have a module but it does not make a connection in the IP table, The default port that cant be changed is 9761 and cannot be changed.


Any help is appreciated.


Thank you


Re: Password for this file?

 

Did anyone find out the password for this? It looks useful


Re: Android TV

 

¿ªÔÆÌåÓý

Hi,

?

I control my Nvidia Shield via CEC ¨C works perfect. I Control my Sony TV via Sony 2014 Bravia TV module. I was just playing around when I Notice I controlled my Shield w/o doing any programming from my Crestron HR-150. It must be CEC I send via my Sony TV.

?

//S

?

Fr?n: Crestron@... <Crestron@...>
Skickat: den 18 januari 2019 06:52
Till: Crestron@...
?mne: [Crestron] Re: Android TV

?

?

I was searching a solution for my shield TV, because IRUSB is not directly available
in Germany it was not that easy to try, asking NVIDIA only gave me the info that it should
be Googles Android TV commands, but didn¡®t find useful info.

I am using Crestrons CBL-USB-RS232KM-6 now, to emulate Keyboard. It works....


Third party I/O

 

Hi all. I'm looking for NON Crestron digital and analog inputs card with a large amount of inputs and outputs (16 and above). To be connected via IP or RS-232 to Crestron controller for indications and control. Priority cost-effective .?Any advice will accepted.

Thanks


Re: Android TV

 

I was searching a solution for my shield TV, because IRUSB is not directly available
in Germany it was not that easy to try, asking NVIDIA only gave me the info that it should
be Googles Android TV commands, but didn¡®t find useful info.

I am using Crestrons CBL-USB-RS232KM-6 now, to emulate Keyboard. It works...


Re: hr150 soft keys

 

left column is odd, right column is even ?according to simplwin help
From: <Crestron@...> on behalf of "chap@... [Crestron]" <Crestron@...>
Reply-To: <Crestron@...>
Date: Thursday, January 17, 2019 at 3:53 PM
To: <Crestron@...>
Subject: [Crestron] hr150 soft keys

?

are they numbered across or down?

Cant find in the docs.


Re: hr150 soft keys

Heather Baiman
 

¿ªÔÆÌåÓý

Across
Hit F1 on the symbol def, I think it shows it there?

Not sent from my flip phone

On Jan 17, 2019, at 6:53 PM, chap@... [Crestron] <Crestron@...> wrote:

are they numbered across or down?

Cant find in the docs.


hr150 soft keys

 

are they numbered across or down?

Cant find in the docs.


Steamist port for communication

 

Hi everyone,


I have a system that I have to connect to this device that is on the network, the manual says to use port 9761 but i look in the ip table and is not connecting.


Any help will be appreciated.


Thank you


Re: String Size

 

If you want to use the MSPs you will need to use separate serials that are 255 or smaller. ?You could put the part that doesn¡¯t change
sendrf,1,8,1
in one called something like Header$ and the rest of it in another like Payload$.

You can connect them to the TX$ using serial buffers with the same serial signal name on the outputs.

You can also send strings larger than 255 by using direct sockets in simpl+


From: <Crestron@...> on behalf of "Ricardo Ferraz ricardo.de.ferraz@... [Crestron]" <Crestron@...>
Reply-To: <Crestron@...>
Date: Thursday, January 17, 2019 at 11:28 AM
To: <Crestron@...>
Subject: [Crestron] String Size

?

Hello Guys,

I need to send this exemple of string with SIO feeding the TX$ TCP Client block

"sendrf,1,8,1,2663,9024,2760,8999,2760,9023,2736,9119,2664,9023,8352,3071,2760,9023,2736,9048,2735,9024,8351,3072,2736,9047,8399,3024,8352,3071,2736,9047,8328,3168,2663,9024,2759,9024,2736,9119,2664,9023,2760,8999,2760,9023,2736,9047,8400,3000,8423,3024,2736,65535\r\n"

But this string is over of 254d supported of the SIO block

Any ideas of how can I send it to the external RF gateway via IP...

Above the log erros from ToolBox.

27. Error: Cannot transmit packet: [06][01][12][00][73][65][6E][64][72][66][2C][32][2C][36][2C][31][2C][31][33][33]... to Slot-05.IP-ID-06.. Packet is too large. (0012:000D:0012)
? ? ?TimeStamp: 16:37:17? 1-17-19? ?UpTime: 0 days 00:17:17.51? Task: LogicPro
?28. Error: Cannot set permanent string value to "sendrf,2,6,1,1332,45...".? Maximum Length = 255, New Length would be 266.? Truncating string to 255 characters. (00AA:0000:00AA)
? ? ?TimeStamp: 16:37:18? 1-17-19? ?UpTime: 0 days 00:17:18.41? Task: LogicPro
?29. Error: Cannot transmit packet: [06][01][12][00][73][65][6E][64][72][66][2C][32][2C][36][2C][31][2C][31][33][33]... to Slot-05.IP-ID-06. Packet is too large. (0012:000D:0012)
? ? ?TimeStamp: 16:37:18? 1-17-19? ?UpTime: 0 days 00:17:18.48? Task: LogicPro
?30. Notice: **Restarting Program**
? ? ?TimeStamp: 16:39:17? 1-17-19? ?UpTime: 0 days 00:19:17.28? Task: ProgramR
?31. Error: Permanent String in symbol S-8.2 was declared as 300 characters - cannot be greater than 255 characters; truncating to 255 characters. (00AE:0000:00AE)
? ? ?TimeStamp: 16:39:17? 1-17-19? ?UpTime: 0 days 00:19:17.61? Task: LogicPro
?32. Error: Cannot set permanent string value to "sendrf,2,6,1,1332,45...".? Maximum Length = 255, New Length would be 266.? Truncating string to 255 characters. (00AA:0000:00AA)
? ? ?TimeStamp: 16:39:30? 1-17-19? ?UpTime: 0 days 00:19:30.36? Task: LogicPro
?33. Error: Cannot transmit packet: [06][01][12][00][73][65][6E][64][72][66][2C][32][2C][36][2C][31][2C][31][33][33]... to Slot-05.IP-ID-06. Packet is too large. (0012:000D:0012)
? ? ?TimeStamp: 16:39:30? 1-17-19? ?UpTime: 0 days 00:19:30..43? Task: LogicPro
?34. Error: Cannot set permanent string value to "sendrf,1,8,1,2663,90...".? Maximum Length = 255, New Length would be 266.? Truncating string to 255 characters. (00AA:0000:00AA)
? ? ?TimeStamp: 16:48:16? 1-17-19? ?UpTime: 0 days 00:28:16.81? Task: LogicPro
?35. Error: Cannot transmit packet: [06][01][12][00][73][65][6E][64][72][66][2C][31][2C][38][2C][31][2C][32][36][36]... to Slot-05.IP-ID-06. Packet is too large. (0012:000D:0012)
? ? ?TimeStamp: 16:48:16? 1-17-19? ?UpTime: 0 days 00:28:16.88? Task: LogicPro
?36. Notice: **Restarting Program**
? ? ?TimeStamp: 16:49:22? 1-17-19? ?UpTime: 0 days 00:29:22.43? Task: ProgramR
?37. Error: Permanent String in symbol S-8.2 was declared as 300 characters - cannot be greater than 255 characters; truncating to 255 characters. (00AE:0000:00AE)
? ? ?TimeStamp: 16:49:22? 1-17-19? ?UpTime: 0 days 00:29:22.76? Task: LogicPro
?38. Error: Cannot set permanent string value to "sendrf,2,6,1,1332,45...".? Maximum Length = 255, New Length would be 266.? Truncating string to 255 characters.. (00AA:0000:00AA)
? ? ?TimeStamp: 16:49:34? 1-17-19? ?UpTime: 0 days 00:29:34.48? Task: LogicPro
?39. Error: Cannot transmit packet: [06][01][12][00][73][65][6E][64][72][66][2C][32][2C][36][2C][31][2C][31][33][33]... to Slot-05.IP-ID-06. Packet is too large. (0012:000D:0012)
? ? ?TimeStamp: 16:49:34? 1-17-19? ?UpTime: 0 days 00:29:34.56? Task: LogicPro
?40. Error: Cannot set permanent string value to "sendrf,2,6,1,1332,45...".? Maximum Length = 255, New Length would be 266.? Truncating string to 255 characters. (00AA:0000:00AA)
? ? ?TimeStamp: 17:17:52? 1-17-19? ?UpTime: 0 days 00:57:52.09? Task: LogicPro
?41. Error: Cannot transmit packet: [06][01][12][00][73][65][6E][64][72][66][2C][32][2C][36][2C][31][2C][31][33][33].... to Slot-05.IP-ID-06. Packet is too large. (0012:000D:0012)
? ? ?TimeStamp: 17:17:52? 1-17-19? ?UpTime: 0 days 00:57:52.16? Task: LogicPro
Total Errors Logged = 41
End of System log

Rgds,
Ricardo


Cambridge Sound Masking System

 

Hello guys.

I need to take cost plan with sound masking installation QTPro series. I dont have time to get offer from Cambridge audio, and maybe some of you know what costs i need to take.

Can I take budget per meter, or maybe from pieces of speakers/zones?

Sound masking saystem is something new for me.


Re: String Size

 

You can send it on 2 lines from an SIO. Use the same digital signal on both lines, and send the string in 2 parts.


Re: connect direct to console in S+

 

thats what I figured. Just hoping that wasnt the case.

thanks though.


Re: connect direct to console in S+

 

¿ªÔÆÌåÓý

IIRC, no there¡¯s no way to talk to the console directly in S+, You¡¯d need to use a console symbol in SIMPL and pass that to SIMPL+.

?

You¡¯re probably getting the redirect because in the latest 3 series firmware, they shut down CTP.

?

Caleb Radecky | Manager, Online Products & Services
Crestron Silver Certified Programmer | DMC-D-4K | DMC-E-4K
ControlWorks Consulting, LLC | Crestron Services Provider | 701 Beta Dr. #22 Cleveland OH 44143
D. 440.771.4809 | O.440.449.1100 X1109 | F.440.449.1106 |

?

From: Crestron@... [mailto:Crestron@...]
Sent: Thursday, January 17, 2019 14:24
To: Crestron@...
Subject: [Crestron] connect direct to console in S+

?

?

I had a host name module working that would use sockets to connect to the console at 127.0.0.1. with port 41795 and grab the host name.?

I now get a REDIRECT:Connect to Secure Port 41797.\x0D\x0A.

If I set the port to 41797, nothing happens.

?

is there a way to connect to the console through s+ now?

?

thanks,

andrew

?


String Size

 

Hello Guys,

I need to send this exemple of string with SIO feeding the TX$ TCP Client block

"sendrf,1,8,1,2663,9024,2760,8999,2760,9023,2736,9119,2664,9023,8352,3071,2760,9023,2736,9048,2735,9024,8351,3072,2736,9047,8399,3024,8352,3071,2736,9047,8328,3168,2663,9024,2759,9024,2736,9119,2664,9023,2760,8999,2760,9023,2736,9047,8400,3000,8423,3024,2736,65535\r\n"

But this string is over of 254d supported of the SIO block

Any ideas of how can I send it to the external RF gateway via IP...

Above the log erros from ToolBox.

27. Error: Cannot transmit packet: [06][01][12][00][73][65][6E][64][72][66][2C][32][2C][36][2C][31][2C][31][33][33]... to Slot-05.IP-ID-06. Packet is too large. (0012:000D:0012)
? ? ?TimeStamp: 16:37:17? 1-17-19? ?UpTime: 0 days 00:17:17.51? Task: LogicPro
?28. Error: Cannot set permanent string value to "sendrf,2,6,1,1332,45...".? Maximum Length = 255, New Length would be 266.? Truncating string to 255 characters. (00AA:0000:00AA)
? ? ?TimeStamp: 16:37:18? 1-17-19? ?UpTime: 0 days 00:17:18.41? Task: LogicPro
?29. Error: Cannot transmit packet: [06][01][12][00][73][65][6E][64][72][66][2C][32][2C][36][2C][31][2C][31][33][33]... to Slot-05.IP-ID-06. Packet is too large. (0012:000D:0012)
? ? ?TimeStamp: 16:37:18? 1-17-19? ?UpTime: 0 days 00:17:18.48? Task: LogicPro
?30. Notice: **Restarting Program**
? ? ?TimeStamp: 16:39:17? 1-17-19? ?UpTime: 0 days 00:19:17.28? Task: ProgramR
?31. Error: Permanent String in symbol S-8.2 was declared as 300 characters - cannot be greater than 255 characters; truncating to 255 characters. (00AE:0000:00AE)
? ? ?TimeStamp: 16:39:17? 1-17-19? ?UpTime: 0 days 00:19:17.61? Task: LogicPro
?32. Error: Cannot set permanent string value to "sendrf,2,6,1,1332,45...".? Maximum Length = 255, New Length would be 266.? Truncating string to 255 characters. (00AA:0000:00AA)
? ? ?TimeStamp: 16:39:30? 1-17-19? ?UpTime: 0 days 00:19:30.36? Task: LogicPro
?33. Error: Cannot transmit packet: [06][01][12][00][73][65][6E][64][72][66][2C][32][2C][36][2C][31][2C][31][33][33]... to Slot-05.IP-ID-06. Packet is too large. (0012:000D:0012)
? ? ?TimeStamp: 16:39:30? 1-17-19? ?UpTime: 0 days 00:19:30.43? Task: LogicPro
?34. Error: Cannot set permanent string value to "sendrf,1,8,1,2663,90...".? Maximum Length = 255, New Length would be 266.? Truncating string to 255 characters. (00AA:0000:00AA)
? ? ?TimeStamp: 16:48:16? 1-17-19? ?UpTime: 0 days 00:28:16.81? Task: LogicPro
?35. Error: Cannot transmit packet: [06][01][12][00][73][65][6E][64][72][66][2C][31][2C][38][2C][31][2C][32][36][36]... to Slot-05.IP-ID-06. Packet is too large. (0012:000D:0012)
? ? ?TimeStamp: 16:48:16? 1-17-19? ?UpTime: 0 days 00:28:16.88? Task: LogicPro
?36. Notice: **Restarting Program**
? ? ?TimeStamp: 16:49:22? 1-17-19? ?UpTime: 0 days 00:29:22.43? Task: ProgramR
?37. Error: Permanent String in symbol S-8.2 was declared as 300 characters - cannot be greater than 255 characters; truncating to 255 characters. (00AE:0000:00AE)
? ? ?TimeStamp: 16:49:22? 1-17-19? ?UpTime: 0 days 00:29:22.76? Task: LogicPro
?38. Error: Cannot set permanent string value to "sendrf,2,6,1,1332,45...".? Maximum Length = 255, New Length would be 266.? Truncating string to 255 characters. (00AA:0000:00AA)
? ? ?TimeStamp: 16:49:34? 1-17-19? ?UpTime: 0 days 00:29:34.48? Task: LogicPro
?39. Error: Cannot transmit packet: [06][01][12][00][73][65][6E][64][72][66][2C][32][2C][36][2C][31][2C][31][33][33]... to Slot-05.IP-ID-06. Packet is too large. (0012:000D:0012)
? ? ?TimeStamp: 16:49:34? 1-17-19? ?UpTime: 0 days 00:29:34.56? Task: LogicPro
?40. Error: Cannot set permanent string value to "sendrf,2,6,1,1332,45...".? Maximum Length = 255, New Length would be 266.? Truncating string to 255 characters. (00AA:0000:00AA)
? ? ?TimeStamp: 17:17:52? 1-17-19? ?UpTime: 0 days 00:57:52.09? Task: LogicPro
?41. Error: Cannot transmit packet: [06][01][12][00][73][65][6E][64][72][66][2C][32][2C][36][2C][31][2C][31][33][33]... to Slot-05.IP-ID-06. Packet is too large. (0012:000D:0012)
? ? ?TimeStamp: 17:17:52? 1-17-19? ?UpTime: 0 days 00:57:52.16? Task: LogicPro
Total Errors Logged = 41
End of System log

Rgds,
Ricardo