¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date

MC3 - Issue

 

I am hoping someone can help me.? My gut is telling me my SD Card is beginning to go on a MC3, but the odd thing is I can load previous versions of my program and write them successfully to the processor.? The minute I make any change and recompile, it ultimately ends up being loaded to the processor, but never runs.? Here is a dump of the error log.? I can't think of what could be causing this.



132. Error: LogicEngine.exe # 2019-01-21 19:34:10? # SplusIntfc: Registration failed = 2

133. Error: LogicEngine.exe [App 1] # 2019-01-21 19:34:10? # Could not find SIMPL+ module Remote_Service_Connection_Manager_v1_1_1.dll in S-12.1:S-3.

134. Fatal: LogicEngine.exe [App 1] # 2019-01-21 19:34:10? # Unable to Load SIMPL+ Module(s) - terminating program load.

135. Exception 'Raised Exception' (-1): Thread-Id=09c4004a(pth=87216910), Proc-Id=0913007a(pprc=874894c8) 'LogicEngine.exe', VM-active=0913007a(pprc=874894c8) 'LogicEngine.exe'

136. PC=4006a020(coredll.dll+0x0005a020) RA=8021a2c8(kernel.dll+0x000062c8) SP=002afcc8, BVA=002afcfc

137. Fatal: LogicEngine.exe [App 1] # 2019-01-21 19:34:10? # Exception [SIMPL+ Module Not Found] in CControlSystem occured

138. Error: LogicEngine.exe [App 1] # 2019-01-21 19:34:12? #? Simpl Plus Manager terminated. Restarting program?

139. Error: LogicEngine.exe [App 1] # 2019-01-21 19:34:21? # Timeout waiting for end of configuration confirmation from slave Slot-02.IP-ID-16.

140. Fatal: LogicEngine.exe [App 1] # 2019-01-21 19:34:42? # Unable to stop S+ exit thread.?

141. Error: TLDM.exe # 2019-01-21 19:34:42? #? CTLDMEthernetStackApplication - Unable to exit App Specific Rcv Thread?

142. Notice: TLDM.exe # 2019-01-21 19:34:44? # **Program 1 Stopped**

143. Error: nk.exe # 2019-01-21 19:34:44? # WDG: LogicEngine shutting down unexpectedly. Do Not Start=0

144. Info: LogicEngine.exe [App 1] # 2019-01-21 19:34:53? # Loading program from \SIMPL\app01

145. Info: LogicEngine.exe [App 1] # 2019-01-21 19:34:53? # Loading Program \SIMPL\app01\FreerTheater - v80.bin.

146. Error: splusmanagerapp.exe [App 1] # 2019-01-21 19:35:27? # Got load exception System.TypeLoadException: File or assembly name 'SimplSharpCryptographyInterface, Version=1.0.6197.21123, Culture=neutral, PublicKeyToken=1099C178B3B54C3B', or one of its dependencies, was not found.

? ?at System.Reflection.Module.GetT147. Error: splusmanagerapp.exe [App 1] # 2019-01-21 19:35:27? # ypes()

? ?at Crestron.Logos.SplusManager.SplusManager.LoadModule(SPLUS_INTERFACE_MODULE_REGISTER_MESSAGE_STRUCT regMsg)

? ?at Crestron.Logos.SplusManager.SplusManager.c()

? ?at Crestron.Logos.SplusManager.SplusManager.aa(Object A_0, EventArgs A_1)

? ?148. Error: splusmanagerapp.exe [App 1] # 2019-01-21 19:35:27? # at Crestron.Infrastructure.CresMsgQ.RaiseDataOnQueueEvent(Object obj, EventArgs args)

? ?at Crestron.Infrastructure.CresMsgQP2P.d()


Re: simpl#

 

This should get you started -?


Steamist Sauna Control

 

Hi everyone


Does anyone have a module that can control this device? I was using the one in the application market but they have changed the ports to udp 30303 and the olde one is 9761 and theres no way to change that.


Any help is appreciated.


Thank you


Re: simpl#

 

¿ªÔÆÌåÓý

Depends on what you mean by ¡®send¡¯.

?

If it¡¯s something synchronous or an async driven from the S+ side you can use a public string (or the return value from a function) to get ¡®read¡¯ S# data

?

If it¡¯s something asynchronous from the S# side you can fire an event with the string in the event args.

?

Beware each time you cross the managed code boundary between S+ and S# you see a bit of a performance penalty so it is best to package data in such a way as to minimize the number of times you¡¯re going back and forth¡­

?

Lincoln

?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Platinum)
ControlWorks Consulting, LLC |
D: (+1)440.771.4807 | O: (+1)440.449.1100? | F: (+1)440.449.1106
Crestron Services Provider | Biamp Authorized Independent Programmers | Extron Qualified Independent Programmer

?

From: Crestron@... <Crestron@...>
Sent: Monday, January 21, 2019 10:11 AM
To: Crestron@...
Subject: [Crestron] simpl#

?




Hi all,

?

Recently embarked on the simpl# journey and there are a few things that I'm struggling with. The main one at the moment is how to send a string from simpl# to simpl+.?

?

Can anyone out there help me with how to do it?

?

cheers,

?

Jon

?





Re: MC3 Email anyone got it working

 

I am using the SendmailSharp_r1 and can not get it to work with Gmail. I have 2 step Authentication password? in the pass word and smtp.gmail.com and my email and a user name. I still get a error. What would I be doing wrong?


Re: Third party I/O

 

take a look at controlanything(dot)com


simpl#

 

Hi all,


Recently embarked on the simpl# journey and there are a few things that I'm struggling with. The main one at the moment is how to send a string from simpl# to simpl+.?


Can anyone out there help me with how to do it?


cheers,


Jon



Re: MC3 Image

 

Yes I am, thanks for clarifying.


Re: Sending commands to Echo

 

¿ªÔÆÌåÓý

Lol


On Jan 19, 2019, at 4:05 PM, Lincoln King-Cliby lincoln@... [Crestron] <Crestron@...> wrote:

?

Put a touchpanel next to the Echo and have it play MP3s ¡°Alexa, unlock the front door¡±

?

Absolutely fool proof :)

?

?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Platinum)
ControlWorks Consulting, LLC |

D: (+1)440.771.4807 | O: (+1)440.449.1100? | F: (+1)440.449.1106
Crestron Services Provider | Biamp Audia Certified | Extron Qualified Independent Programmer

?

From: Crestron@... [mailto:Crestron@...]
Sent: Friday, January 18, 2019 11:10 AM
To: Crestron@...
Subject: [Crestron] Sending commands to Echo

?




Maybe I have missed it, but I am wondering if we have a way to send commands to Alexa to operate things it controls that we do not currently have direct control of but it does. ?Is there a way for me to have Crestron tell Alexa to lock the door, for example.





Re: Sending commands to Echo

 

Or stick one of these to your Alexa and have it play audio files:


On Sat, Jan 19, 2019 at 5:06 PM Lincoln King-Cliby lincoln@... [Crestron] <Crestron@...> wrote:
?

Put a touchpanel next to the Echo and have it play MP3s ¡°Alexa, unlock the front door¡±

?

Absolutely fool proof :)

?

?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Platinum)
ControlWorks Consulting, LLC |

D: (+1)440.771.4807 | O: (+1)440.449.1100? | F: (+1)440.449.1106
Crestron Services Provider | Biamp Audia Certified | Extron Qualified Independent Programmer

?

From: Crestron@... [mailto:Crestron@...]
Sent: Friday, January 18, 2019 11:10 AM
To: Crestron@...
Subject: [Crestron] Sending commands to Echo

?




Maybe I have missed it, but I am wondering if we have a way to send commands to Alexa to operate things it controls that we do not currently have direct control of but it does.? Is there a way for me to have Crestron tell Alexa to lock the door, for example.





Samsung UE55Hu7500T

 

Does anyone have a module to control samsung TV's on IP in the UK or works in UK please? Also bluray would be fab too, looked on market place but all seem to be US.


Many Thanks Guys


Re: Sending commands to Echo

 

¿ªÔÆÌåÓý

Put a touchpanel next to the Echo and have it play MP3s ¡°Alexa, unlock the front door¡±

?

Absolutely fool proof :)

?

?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Platinum)
ControlWorks Consulting, LLC |

D: (+1)440.771.4807 | O: (+1)440.449.1100? | F: (+1)440.449.1106
Crestron Services Provider | Biamp Audia Certified | Extron Qualified Independent Programmer

?

From: Crestron@... [mailto:Crestron@...]
Sent: Friday, January 18, 2019 11:10 AM
To: Crestron@...
Subject: [Crestron] Sending commands to Echo

?




Maybe I have missed it, but I am wondering if we have a way to send commands to Alexa to operate things it controls that we do not currently have direct control of but it does. ?Is there a way for me to have Crestron tell Alexa to lock the door, for example.





Re: Samsung DB55e direct channel call?

 

Do you have information on how the Channel (Major and/or Minot) Hi-Low are divided up between the two bytes?
I don't currently have a TV to test against.


On Wed, Feb 7, 2018 at 12:48 PM jaaron7@... [Crestron] <Crestron@...> wrote:
?

What specifically are you looking for? I don't think I've used a DB-E model, but Samsung commercial monitors all use the same commands. Direct channel control is poorly documented as always, but it does work on the models I've needed it for.




"The direct channel control is tricky, and took me a while to figure out. On the ME-C series, it would only let me send a direct number if it was already programmed in the monitor (channel scan).

From the manual:

Channel Query:
0xAA 0x17 0x00

Set Channel:
0xAA 0x17 0x08 <Minor-Hi>

Ack:
0xAA 0xFF 0x0A 'A' 0x17

Nak:
0xAA 0xFF 0x03 'N' 0x17


Country: 0 for Korea, 1 for US
ATV/DTV: 0 for Analog, 1 for Digital
Air/Cable: 0 for Antenna, 1 for Cable
Channel: high byte and low byte of channel in hex, 1-135 for Analog, 0-999 for digital
Sel-Minor: 0 for no minor channel, 1 for select minor channel
Minor: high byte and low byte of minor channel in hex, 0-999"

?


Re: Sending commands to Echo

 

It didn't work, thought you could send triggers from smart devices but you can't, only things in the devices tab(motion detectors, contacts, and I believe Samsung smart things).


Re: Sending commands to Echo

 

I was literally just thinking about this exact thing 2 hours ago, haven't tried it since I was at work. But I was thinking if you created a dummy light load in your crestron program using logic to actually drive it and then obviously discovered it with alexa, that you could set up a routine from there when the device did something. Just a thought, like I said, haven't tested it out yet. Hope it helps. Kevin


Re: Fusion discovery with multiple programs?

 

¿ªÔÆÌåÓý

Thank you for your reply Jason.?

?As I indicated in an earlier email each programs¡¯ fusion symbol has a unique IP ID.

Thank you.


On Jan 18, 2019, at 2:03 PM, jasonmussetter@... [Crestron] <Crestron@...> wrote:

?

The GUID is separate than the IPID.? The SSI module will take care of the GUID being unique.? However, if you loaded the same program into multiple slots, then the modules are probably all defined on the same IP-ID, which can't work.

You can only have an IP-ID defined for one slot, not sharing.? So you either need to move them IP-ID in the code for slots 2-10 and recompile, so all slots have the Fusion SSI module on different IPID's from each other, or maybe do some IP-ID remapping.

If all slots have the SSI module defined on same IPID, only the first slot is using it, and locking it out of the other ones since it can't be shared.? That is why you can only discover one program and not the others.


Sending commands to Echo

 


Re: Fusion discovery with multiple programs?

 

¿ªÔÆÌåÓý

? Interesting... Why have the 1 on the update digital? In Fusion class they had us pulse it at midnight. Do you know what the limit is for Fusion Room symbols in one program slot? The FSG folks had me set it up this way. They are super helpful, just very busy. They are contacting me Monday morning. Thanks for the info William.


On Jan 18, 2019, at 1:01 PM, williamprice880@... [Crestron] <Crestron@...> wrote:

?

Additionally I use a different Fusion SSI ID for each slot or process plus I have a 1 on Digital Signal Update System Info on SSI 2.5. For the record, apart from the main program running on slot 1 I actually run a second slot with several rooms defined on them all with different IPID and SSI IDs. This is to follow room scheduling for rooms that do not have Crestron yet. In one case I have 6 rooms running on one slot zero issue.


Re: Fusion discovery with multiple programs?

 

The GUID is separate than the IPID.? The SSI module will take care of the GUID being unique.? However, if you loaded the same program into multiple slots, then the modules are probably all defined on the same IP-ID, which can't work.

You can only have an IP-ID defined for one slot, not sharing.? So you either need to move them IP-ID in the code for slots 2-10 and recompile, so all slots have the Fusion SSI module on different IPID's from each other, or maybe do some IP-ID remapping.

If all slots have the SSI module defined on same IPID, only the first slot is using it, and locking it out of the other ones since it can't be shared.? That is why you can only discover one program and not the others.


Re: Fusion discovery with multiple programs?

 

I'm looking at my working setup Bottom parameters on the 2.5 SSI Here's what i got for CP3N
Processor Type Standard
Primary SSI NO
Prefix_GUID Yes
Append_Program_Slot Yes
File Location Internal
Fusion SSI ID 10d (11 for next one etc..)
Scheduling ID 10d (I use a scheduling module so i increment that for every room as well)
Use Time Sync No.

My Ethernet offline manager is looped with the update request from the right side to "offline" on the left
Digital Signal Update_System_Info on SSI module is set to 1
My fusion ids are set starting F0 and increment to F1 and F2 etc....

Finally my last SSI module has a [To_Program_Initt_Complete] digital signal that I actually send to CP3_USERPROGRAMINIT to let it know initialization is complete for all modules.
Nothing else not GUI modules or else.